Electrical installation
Control terminals
l
33
LDEDS−CCU210B EN 4.0
6.5
Control terminals
Device in a power range of 1.5 kW and 2.2 kW
Devices in a power range of 0.75 kW
CCU210_002E
CCU_210_002G
Common control terminals
X50 − external data memory
Pin
Signal
Description
Data
EXMID1
Connector: socket, 8−pole, M12
Connection of external data
memory
Max. 2 kB
Depending on the application
X51 – anti−collsion sensor for RS485 SensoPart forward travel
Pin
Signal
Description
Data
Connector: socket, 5−pole, M12, B−coded
1
+24V
Supply
2
A
RS485 signal A
3
GND
Reference potential
4
B
RS485 signal B
5
n. c.
Not assigned
−
Shld
Shield
Applied to the connector housing
X60, X61 – CAN system bus connection
Pin
Signal
Description
Data
Two CAN system bus terminals for
parameter setting and
configuration
Connector: RJ45
Control terminals for devices in a power range of 1.5 kW and 2.2 kW
X40 − digital inputs DIN3 ... DIN7/digital output DOUT2
Pin
Signal
Description
Data
Connector: socket, 8−pole, M12
1
DIN3
Digital input 3
HIGH
+16 .... +26.5 V DC
2
DIN4
Digital input 4
LOW
0 ... +4 V
3
DIN5
Digital input 5
4 mA
Current per input for 24 V DC
4
DIN6
Digital input 6
max.
200 mA
Permissible current loading per
output
If inductive loads are switched,
use a freewheeling diode as
close to the inductive load as
possible!
5
+24V DC
Supply
6
DIN7
Digital input 7
7
GND
Reference potential
8
DOUT2
Digital output 2