Parameter reference
15.2
Parameter list
974
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00820
C00821
Value is bit-coded:
Bit 0 No blocking zone active
Bit 1 Blocking zone 1 active
Bit 2 Blocking zone 2 active
Bit 3 Blocking zone 3 active
Bit 4 Value in blocking zone
Bit 5
Reserved
Bit 6
Reserved
Bit 7
Reserved
Bit 8
Reserved
Bit 9
Reserved
Bit 10
Reserved
Bit 11
Reserved
Bit 12
Reserved
Bit 13
Reserved
Bit 14
Reserved
Bit 15
Reserved
Subcodes
Info
C00812/1
: Current status
C00812/2
: Current status
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Parameter | Name:
C00812 | L_NLim: Current status
Data type: UNSIGNED_16
Index: 23763
d
= 5CD3
h
Parameter | Name:
C00820 | L_DigitalLogic_1: Function
Data type: UNSIGNED_8
Index: 23755
d
= 5CCB
h
The
FB: Selection of the internal logic function
Selection list
(Lenze setting printed in bold)
Info
0 bOut = 0
Constant value "FALSE"
1 bOut = 1
Constant value "TRUE"
2 bOut = bIn1 AND bIn2 AND bIn3
AND operation
3 bOut = bIn1 OR bIn2 OR bIn3
OR operation
4 bOut = f (truth table)
The truth table parameterised in
is used.
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00821 | L_DigitalLogic_1: Truth table
Data type: UNSIGNED_8
Index: 23754
d
= 5CCA
h
The
FB: Parameterisation of the truth table
Selection list
0 False
1 True
Subcodes
Lenze setting
Info
C00821/1
0: FALSE
: bOut: bIn3...bIn1=0 0 0
C00821/2
0: FALSE
: bOut: bIn3...bIn1=0 0 1