15
Parameter reference
15.2
Parameter list
950
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00680
C00681
C00682
C00685
Parameter | Name:
C00680 | L_Compare_1: Fct.
Data type: UNSIGNED_8
Index: 23895
d
= 5D57
h
The
FB: Comparison operation
• If the statement of the selected comparison operation is true, the binary
bOut
output will be set to TRUE.
Selection list
(Lenze setting printed in bold)
1 In1 = In2
2 In1 > In2
3 In1 < In2
4 |In1| = |In2|
5 |In1| > |In2|
6 |In1| < |In2|
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00681 | L_Compare_1: Hysteresis
Data type: INTEGER_16
Index: 23894
d
= 5D56
h
The
FB: Hysteresis for the comparison function selected in
Setting range
(min. value | unit | max. value)
Lenze setting
0.00
%
100.00
0.50 %
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 100
Parameter | Name:
C00682 | L_Compare_1: Window
Data type: INTEGER_16
Index: 23893
d
= 5D55
h
The
FB: Window for the comparison function selected in
Setting range
(min. value | unit | max. value)
Lenze setting
0.00
%
100.00
2.00 %
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 100
Parameter | Name:
C00685 | L_Compare_2: Fct.
Data type: UNSIGNED_8
Index: 23890
d
= 5D52
h
The
FB: Comparison operation
• If the statement of the selected comparison operation is true, the binary
bOut
output will be set to TRUE.
Selection list
(Lenze setting printed in bold)
1 In1 = In2
2 In1 > In2
3 In1 < In2
4 |In1| = |In2|
5 |In1| > |In2|
6 |In1| < |In2|
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1