4
Device control (DCTRL)
4.1
Device commands (C00002/x)
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
4.1.7
Delete logbook
= "1: On / start" device command deletes all logbook entries.
Tip!
To display the logbook in the »Engineer«, click the
Logbook
button on the
Diagnostics
tab.
In the
Logbook
dialog box, it is also possible to delete all logbook entries by clicking the
Delete
button.
Detailed information on the logbook can be found in the "
" chapter.
4.1.8
Device search function
This function extension is available from version 06.00.00!
In some applications where inverters are installed in control cabinets or are positioned in a spacious
plant, it is often difficult to locate a device connected online for e.g. maintenance work. There is an
established online connection with the device but you do not know where the inverter is located
physically.
The
= "1: On / start" device command serves to carry out an "optical location":
• For the time set in
, all four status LEDs at the front of the inverter flash. Afterwards,
the function is turned off automatically.
• If the device command is executed again within the set time period, the duration is extended
accordingly.
• The setting
= "0: Off / ready" serves to abort or switch off the function.
• Adjustable time period: 0 ... 6000 s (Lenze setting: 5 s)
Tip!
The device search function can also be activated via the
toolbar
icon.