Firmware 03.00 - DMS EN 5.0 - 07/2009
L
183
8400 BaseLine D | Software Manual
Parameter reference
Parameter list | C00054 |
C00054 |
C00056 |
C00057 |
C00058 |
C00059 |
C00061
Parameter | Name:
C00054 | Motor current
Data type: UNSIGNED_16
Index: 24521
d
= 5FC9
h
Display of the current motor current /output current of the inverter
Display range
(min. value | unit | max. value)
0.00
A
300.00
;
Read access
Write access
CINH
PLC STOP
;
No transfer
COM
MOT
Scaling factor: 100
Parameter | Name:
C00056 | Torque
Data type: INTEGER_32
Index: 24519
d
= 5FC7
h
Display of the current motor torque
Display range
(min. value | unit | max. value)
-99.00
Nm
99.00
Subcodes
Info
C00056/1
Torque setpoint
• Only for SLVC operating mode.
C00056/2
Torque actual value
• Estimated actual torque for all operating modes.
;
Read access
Write access
CINH
PLC STOP
;
No transfer
COM
MOT
Scaling factor: 100
Parameter | Name:
C00057 | Maximum torque
Data type: UNSIGNED_32
Index: 24518
d
= 5FC6
h
Display of the maximum torque to be generated by the motor
• The maximum torque to be generated by the motor depends on various factors, e.g. on Imax in motor mode
) and the motor type used.
Display range
(min. value | unit | max. value)
0.0
Nm
999.9
;
Read access
Write access
CINH
PLC STOP
;
No transfer
COM
MOT
Scaling factor: 100
Parameter | Name:
C00058 | Output frequency
Data type: INTEGER_32
Index: 24517
d
= 5FC5
h
Display of the current output frequency
Display range
(min. value | unit | max. value)
-655.0
Hz
655.0
;
Read access
Write access
CINH
PLC STOP
;
No transfer
COM
MOT
Scaling factor: 100
Parameter | Name:
C00059 | Appl.: Reference frequency C11
Data type: UNSIGNED_32
Index: 24516
d
= 5FC4
h
Display of the field frequency which corresponds to the reference speed set in
.
Display range
(min. value | unit | max. value)
0.0
Hz
999.9
;
Read access
Write access
CINH
PLC STOP
;
No transfer
COM
MOT
Scaling factor: 100
Parameter | Name:
C00061 | Heatsink temperature
Data type: INTEGER_16
Index: 24514
d
= 5FC2
h
Display of the current heatsink temperature
Display range
(min. value | unit | max. value)
-50
°C
150
;
Read access
Write access
CINH
PLC STOP
;
No transfer
COM
MOT
Scaling factor: 1