Fig. 30: Signal flow in the technology application
In the "Technology application" dialogue of the »EASY Starter« software, the parameter Appli-
cation selection shows which technology application is active. The technology application can
be modified in this dialogue.
Parameter
Address
Name / setting range / [default setting]
Info
0x4000
Application selection
•
Setting can only be changed if the inverter is inhibi-
ted.
0 "CiA 402" technology application
10 "Speed Control" technology application
20 "Table Positioning" technology application
40 "Electronic Gearbox" technology application
41 "Sync and Correction" technology applica-
tion
50 "Winder Dancer" technology application
51 "Winder Tension" technology application
10000 "User" technology application
7.1
Control settings
General variables such as starting values, reference variables, and signal sources must be
defined before the control system of the technology application is configured.
Settings in "EASY Starter":
•
Settings tab
•
Technology application parameter dialogue for
•
Relevant parameters of other functions
Address
Designation
Default setting
Setting range
Interface selection
Fieldbus network [0]
Selection list
Application quick stop source
FALSE [0]
Selection list
Source of fault reset
FALSE [0]
Selection list
Master value source
System bus [0]
Selection list
Source of digital output 1
Ready to switch on [0]
Selection list
0x5040:006
Display value 1
[8]
Selection list
Configuring the "Sync and Correction" TA
Control settings
90