5.4.2
Manual setting of the motor data
There are two options to parameterise a motor.
1. Enter nameplate data
Enter the following motor data:
Number of pole pairs
Stator resistance
Stator leakage inductance
Rated speed
Rated frequency
Rated power
Rated voltage
Cosine phi
Insulation class
Rated motor current
When you touch the "Estimate" button in the engineering tool, more parameters depending
on the motor are shown.
2. Enter data of the motor data sheet
The motor data and the parameters depending on the motor are entered. The parameters
mentioned under 1. are the following:
Thermal time constant of the winding
Thermal time constant - laminated core
Rated motor torque
Additionally for ASM:
Rotor resistance
Mutual inductance
Magnetising current
Additionally for PSM:
EMF constant
Resolver pole position
Temperature coefficient magnets (kTN)
Encoder pole position
After the motor data has been parameterised via one of the two options, the following moni-
toring and limit values are initialised with motor-dependent preset values by touching the
"Initialise" button:
Overspeed monitoring threshold
Overcurrent monitoring threshold
Motor temperature monitoring warning threshold
Motor temperature monitoring error threshold
Maximum current
Rated motor current
Basic setting
Motor data
Manual setting of the motor data