0x2C01:001
Motor parameters: Number of pole pairs
•
Read only
Display of the number of pole pairs calculated from the rated speed and
rated frequency.
0x2C01:002
Motor parameters: Stator resistance
0.0000 ... [13.5000] ... 125.0000 Ω
General motor data.
Carry out settings as specified by manufacturer data/motor data sheet.
Note!
When you enter the motor nameplate data, take into account the phase
connection implemented for the motor (star or delta connection). Only
enter the data applying to the connection type selected.
0x2C01:003
Motor parameters: Stator leakage inductance
0.000 ... [51.000] ... 500.000 mH
0x2C01:004
Motor parameters: Rated speed
0 ... [4050] ... 50000 rpm
General motor data.
Carry out settings as specified by motor nameplate data.
Note!
When you enter the motor nameplate data, take into account the phase
connection implemented for the motor (star or delta connection). Only
enter the data applying to the connection type selected.
0x2C01:005
Motor parameters: Rated frequency
0.0 ... [270.0] ... 1000.0 Hz
0x2C01:006
Motor parameters: Rated power
0.00 ... [0.25] ... 655.35 kW
0x2C01:007
Motor parameters: Rated voltage
0 ... [225] ... 65535 V
0x2C01:008
Motor parameters: Cosine phi
0.00 ... [0.80] ... 1.00
0x2C01:009
Motor parameters: Insulation class
Insulation class of the motor (see motor nameplate).
0 Y (cut-off temperature = 90 °C)
1 A (cut-off temperature = 105 °C)
2 E (cut-off temperature = 120 °C)
3 B (cut-off temperature = 130 °C)
4 F (cut-off temperature = 155 °C)
5 H (cut-off temperature = 180 °C)
6 G (cut-off temperature > 180 °C)
0x2C02:001
Motor parameter (ASM): Rotor resistance
0.0000 ... [0.0000] ... 214748.3647 Ω
Equivalent circuit data required for the motor model of the asynchro-
nous machine.
0x2C02:002
Motor parameter (ASM): Mutual inductance
0.0 ... [0.0] ... 214748364.7 mH
0x2C02:003
Motor parameter (ASM): Magnetising current
0.00 ... [0.00] ... 500.00 A
0x2C03:001
Motor parameter (PSM): Back EMF constant
0.0 ... [41.8] ... 100000.0 V/1000rpm
Voltage induced by the motor (rotor voltage / 1000 rpm).
For permanently excited synchronous motors, the e.m.f. constant
describes the r.m.s. value of the line-to-line voltage (phase voltage)
induced in idle state by the motor (reference: 1000 rpm, 20 °C).
0x2C03:002
Motor parameter (PSM): Resolver pole position
-179.9 ... [-90.0] ... 179.9 °
Equivalent circuit data required for the motor model of the synchronous
machine.
0x2C03:003
Motor parameter (PSM): Magnets temperature coeffi-
cient (kTN)
-1.000 ... [-0.110] ... 0.000 %/°C
0x2C03:004
Motor parameter (PSM): Encoder pole position
-179.9 ... [0.0] ... 179.9 °
0x2D4C:001
Thermisches Modell Motorauslastung (i²xt): Motor
utilisation (i²xt)
1 ... [60] ... 36000 s
Setting of the time constant for the winding.
0x2D4C:002
Thermisches Modell Motorauslastung (i²xt): Thermal
time constant - laminations
1 ... [852] ... 36000 s
Setting of the time constant for the laminated core.
0x2D4C:003
Thermisches Modell Motorauslastung (i²xt): Winding
influence
0 ... [27] ... 100 %
Part of the thermal motor model: distribution factor of the copper wind-
ing influence.
Basic setting