17
Device functions
17.1
Optical device identification
For applications including several interconnected inverters it may be difficult to locate a device
that has been connected online. The "Optical device identification" function serves to locate
the inverter by means of blinking LEDs.
Details
In order to start the visual tracking,
•
click the button in the toolbar of the »EASY Starter« or
•
set
= "Start [1]".
After the start, both LEDs "RDY" and "ERR" on the front of the inverter synchronously blink
very fast.
"RDY" LED (blue)
"ERR" LED (red)
Status/meaning
Both LEDs are blinking in a very rapidly synchro-
nous mode
"Visual tracking" function is active.
The blinking duration can be set in
or selected in the »EASY Starter« in the drop-
down list field:
Parameter
Address
Name / setting range / [default setting]
Info
0x2021:001
Optical tracking: Start detection
1 = start optical device identification.
•
After the start, the two LEDs "RDY" and "ERR" on the front of the
inverter are blinking with a blinking frequency of 20 Hz for the blink-
ing duration set in
. The setting is then automatically reset
to "0" again.
•
If the function is reactivated within the blinking time set, the time is
extended correspondingly.
•
A manual reset to "0" makes it possible to stop the function prema-
turely.
0 Stop
1 Start
0x2021:002
Optical tracking: Blinking duration
0 ... [5] ... 6000 s
Setting of the blinking duration for the visual tracking.
Device functions
Optical device identification
377