16.4.4
Monitoring
Monitoring of the master/slave functionality
The following scenarios are monitored:
•
The inverter at position 1 is not configured as system bus master.
•
Several inverters have been configured as system bus master.
Depending on the assignment of the system bus interfaces X246 (EtherCAT IN) and X247
(EtherCAT OUT) and the set interface role in
(master/slave), a warning is output:
Network cable plugged in X246/X247
(Slave)
= 1
(Master)
Only X246 (EtherCAT IN) is assigned.
OK
Warning
Only X247 (EtherCAT OUT) is assigned.
Warning
OK
X246 (EtherCAT IN) and X247 (EtherCAT OUT) are assigned.
OK
Warning
The parameters for setting network monitoring functions are described below.
Parameter
Address
Name / setting range / [default setting]
Info
0x285B:001
EtherCAT system bus monitoring: Watchdog abgelau-
fen
0 No response
1 Fault > CiA402
2 Warning
0x285B:002
EtherCAT system bus monitoring: EtherCAT role check
0 No response
1 Fault > CiA402
2 Warning
Configuring the network
EtherCAT system bus
Monitoring
372