16.1.6.4
Switched on
This is the device state of the inverter after the "
" command has been triggered in
" device state.
•
Process data monitoring is active.
•
Communication is possible.
•
The DC-bus voltage is available.
•
The inverter can be parameterised.
•
If the internal holding brake control (
) is active in the inverter, the motor brake
is closed.
•
Operation is inhibited.
1
From all states
2
Power section inhibited (pulse inhibit)
3
Power section enabled
Bit pattern in the CiA 402 status word (
Bit 15 ... 8
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Reserved
(specific)
Warning
active
Operation
inhibited
Quick stop
active
DC bus ready
for operation
Fault active
Operation
enabled
Switched on
Ready to
switch on
X
X
1
1
X
0
0
1
1
X = state is not relevant
Configuring the network
Device profile CiA 402
Device states
329