![Lenze i950 Series Manual Download Page 171](http://html.mh-extra.com/html/lenze/i950-series/i950-series_manual_1882145171.webp)
10
Configure speed control
Two operating modes are available for configuring the speed control:
•
Operating mode "CiA 402 Velocity mode (vl)"
Here, a speed-controlled movement of the drive is realised by defining a speed setpoint.
•
Operating mode "CiA 402 Cyclic sync velocity mode (csv)"
This operating mode provides a fast speed follower with torque/feed force feedforward
control.
The conditions are a correct entry of the motor data (
) and the parameter setting
of the motor control (
).
10.1
Basic setting
The following describes the steps required for configuring the speed control.
1
.
Set the manufacturer spanning operating mode " CiA: Velocity mode [2]" or " Cyclic
sync velocity mode [9]".
-
A detailed description of the " CiA: Velocity mode " operating mode can be found in the
Operating mode "CiA 402 Velocity mode (vl)"
.
-
A detailed description of the " Cyclic sync velocity mode " operating mode can be
found in the section
Operating mode "CiA 402 Cyclic sync velocity mode (csv)"
2
.
Set the maximum motor speed in Max motor speed .
3
.
Set the rated motor torque in Motor rated torque .
4
.
Set the positive torque limit.
5
.
Set the negative torque limit.
The speed control is now active and the inverter responds to the speed setpoint.