Parameter reference
13.3
Table of attributes
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
13.3
Table of attributes
The table of attributes contains information required for communicating with the Inverter Drive
8400 via parameters.
How to read the table of attributes:
Column
Meaning
Entry
Code
Parameter designation
Cxxxxx
Name
Parameter short text (display text)
Text
Index
dec
Index by which the parameter is addressed.
The subindex for array variables corresponds to the
Lenze subcode number.
24575 - Lenze- code
Only required for access via a bus
system
hex
5FFF
h
- Lenze code number
Data
DS
Data structure
E
Single variable
(only one parameter element)
A
Array variable
(several parameter elements)
DA
Number of the array elements (subcodes)
Number
DT
Data type
BITFIELD_8
1 byte, bit-coded
BITFIELD_16
2 bytes, bit-coded
BITFIELD_32
4 bytes, bit-coded
INTEGER_8
1 byte, with sign
INTEGER_16
2 bytes, with sign
INTEGER_32
4 bytes, with sign
UNSIGNED_8
1 byte, without sign
UNSIGNED_16
2 bytes, without sign
UNSIGNED_32
4 bytes, without sign
VISIBLE_STRING
ASCII string
OCTET_STRING
Factor
Factor for data transmission via a bus system,
depending on the number of decimal positions
Factor
1
≡
no decimal positions
10
≡
1 decimal position
100
≡
2 decimal positions
1000
≡
3 decimal positions
Access
R
Read access
;
Reading permitted
W
Write access
;
Writing permitted
CINH
Controller inhibit (CINH) required
;
Writing only possible if the controller is inhibited (CINH)