6
Commissioning
6.5
Establishing an online connection with the »Engineer«
42
Lenze · E84AYCET communication module (EtherCAT) · Communication Manual · DMS 5.0 EN · 05/2013 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
How to configure an online connection to a field device which is connected to the Lenze
Controller via EtherCAT:
1. Go to the
Communication path
dialog box and the
Bus connection
list field, and select the
entry "Gateway Controller -> EtherCAT" there.
2. Click
Search/Enter...
.
The
Gateway Controller -> Set up EtherCAT bus
dialog box is shown:
3. Enter the
IP address
of the Controller.
By clicking the
Ping
button, you can carry out a simple test which verifies whether a device
can actually be reached via the IP address set
4. Click
OK
.
• The
Enter IP address
dialog box is closed.
• In the
Communication path
dialog box in the
Device access path
column, the
corresponding device access path
is shown
(e.g. "IPC:172_31_207_254.ECAT.ecat1.dev1001.").