Technical data
2
23
EDKRBD180R DE/EN/FR 2.0
2
Technical data
Standards
Conformity
CE
Low-Voltage Directive
Approvals
UL
UL508, Industrial Control Equipment,
Underwriter Laboratories (File-No.
E208678) for USA and Canada
Operating conditions
Permissible ambient
operating
temperature
-10 °C ... +55 °C
Above 40 °C the continuous power P
d
is to be reduced by 2.5 %/°C
Permissible site
altitude
0 ... 4000 m amsl
Above 1000 m the continuous power P
d
is to be reduced by 5 %/1000 m
Type of protection
IP20 (NEMA 250 type 1)
Mounting position
Vertically suspended with terminal box at the bottom
Operating conditions
z
Mean value of regenerative power < permanent power of brake resistor
z
Regenerative power during braking time < thermal capacity of brake
resistor
z
Braking time < 10 % of cycle time (braking time + recovery time)
Rated data
Type
Resistance
Continuous
power
Thermal
capacity
Operating
voltage
Mass
R
B
[
Ω
]
P
d
[W]
C
B
[kWs]
U
max
[V
DC
]
m [kg]
ERBD180R300W
180
300
45
800
2.0
ERBD100R600W
100
600
83
800
3.1
ERBD082R600W
82
600
87
800
3.1
ERBD068R800W
68
800
120
800
4.3
ERBD047R01K2
47
1200
174
800
4.9
ERBD033R02K0
33
2000
240
800
7.1
ERBD022R03K0
22
3000
375
800
10.6
ERBD018R01K6
18
1600
240
800
6.8
ERBD018R03K0
18
3000
375
800
10.6
ERBD015R04K0
15
4000
547
900
12.4
ERBD018R06K0
18
6000
900
800
22.6
Show/Hide Bookmarks