Configuration
Configuring system bus (CAN)
Setting CAN node address and baud rate
96
EDBCSXE040 EN 6.0
Node address setting
The node address is set by means of switches 2 ... 7 of the DIP switch. Specific values are
assigned to the switches. The sum of the values specifies the node address to be set (see
example).
Switch
Value
Example
Switching status
Node address
ON
OFF
ON
1
6
2
7
4
3
8
5
91
0
S1
OFF:
Node address setting is only valid for CAN
(C0350 is overwritten if one of switches S2 ... S7
is in ON position.)
ON:
Node address setting is valid for CAN and
CANaux (C0350 and C2450 are overwritten if
one of switches S2 ... S7 is in ON position.)
−
S2
32
ON
32 + 16 + 8 =
56
S3
16
ON
S4
8
ON
S5
4
OFF
S6
2
OFF
S7
1
OFF
Baud rate setting
Note!
The baud rate must be set identically for all CAN nodes.
Switch
Baud rate [kbit/s]
1000
500
250
125
50
ON
OFF
ON
1
6
2
7
4
3
8
5
91
0
8
ON
OFF
OFF
OFF
OFF
9
OFF
OFF
OFF
ON
ON
10
OFF
OFF
ON
OFF
ON