Mechanical installation
Important notes
4
99
EDKCSDX064 DE/EN/FR 4.0
4
Mechanical installation
4.1
Important notes
ƒ
Axis modules of the ECS series provide IP20 enclosure and can therefore
only be used for installation in control cabinets.
ƒ
If the cooling air contains air pollutants (dust, fluff, grease, aggressive
gases):
–
Take suitable preventive measures , e.g. separate air duct, installation
of filters, regular cleaning.
ƒ
Possible mounting positions:
–
Vertical at the mounting plate
–
DC bus connections (X23) at the top
–
Motor connection (X24) at the bottom
ƒ
Maintain the specified clearances (above and below) to other
installations!
–
If the ECSZS000X0B shield mounting kit is used, an additional clearance
is required.
–
Ensure unimpeded ventilation of cooling air and outlet of exhaust air.
–
Several modules of the ECS series can be installed in the control cabinet
next to each other without any clearance.
ƒ
The mounting plate of the control cabinet
–
must be electrically conductive.
–
must not be varnished.
ƒ
In case of continuous vibrations or shocks use shock absorbers.