Parameter reference
13.3
Parameters of the communication module for slot MXI2
103
Lenze · E94AYCEO communication module (EtherNet/IP™) · Communication Manual · DMS 3.0 EN · 12/2013 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
13.3
Parameters of the communication module for slot MXI2
This chapter lists the parameters of the E94AYCEO communication module (EtherNet/IP) for slot
MXI2 of the Servo Drive 9400 in numerically ascending order.
C14000
C14001
C14002
Parameter | Name:
C14000 | IP address
Data type: UNSIGNED_8
Index: 10575 = 0x294F
Setting of the IP address
Setting the IP configuration of the Servo Drive 9400 (
Setting range
(min. value | unit | max. value)
0
255
Subcodes
Lenze setting
Info
C14000/1
192
IP address (most significant byte)
C14000/2
168
IP address
C14000/3
124
IP address
C14000/4
16
IP address (least significant byte)
Read access
Write access
CINH
PLC STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT
Parameter | Name:
C14001 | Subnetwork mask
Data type: UNSIGNED_8
Index: 10574 = 0x294E
Setting of the subnet mask
Setting the IP configuration of the Servo Drive 9400 (
Setting range
(min. value | unit | max. value)
0
255
Subcodes
Lenze setting
Info
C14001/1
255
Subnet mask (most significant byte)
C14001/2
255
Subnet mask
C14001/3
255
Subnet mask
C14001/4
0
Subnet mask (least significant byte)
Read access
Write access
CINH
PLC STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT
Parameter | Name:
C14002 | Gateway address
Data type: UNSIGNED_8
Index: 10573 = 0x294D
Setting of the gateway address
Setting the IP configuration of the Servo Drive 9400 (
Setting range
(min. value | unit | max. value)
0
255
Subcodes
Lenze setting
Info
C14002/1
0
Gateway address (most significant byte)
C14002/2
0
Gateway address
C14002/3
0
Gateway address
C14002/4
0
Gateway address (least significant byte)
Read access
Write access
CINH
PLC STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT