EDS94AYCCA EN 5.0 - 06/2012
L
139
E94AYCCA communication manual (CANopen®)
Parameter reference
Parameters of the communication module for slot MXI2
C14373
C14374
Parameter | Name:
C14373 | CAN SDO server Tx identifier
Data type: BITFIELD_32
Index: 11202
d
= 2BC2
h
Identifier with which the corresponding SDO server can carry out transmissions.
• If bit 31 is set (0x8nnnnnnn), the corresponding SDO server is deactivated.
• Mapping of the CANopen objects
(see DS301, V4.02).
Identifiers of the parameter data objects (
Setting range
0x00000000
0xFFFFFFFF
Value is bit-coded:
Information
Bit 0 COB-ID bit 0
• Bit 0 ... 10: COB-ID
• Bit 11 ... 30: Reserved
• Bit 31: SDO invalid
... ...
Bit 31 SDO invalid
Subcodes
Lenze setting
Information
C14373/1
0x00000581
SDO server channel 1 TX
• Subcode 1 contains the basic SDO channel. According
to DS301, V4.02 it can neither be changed nor
deactivated. Writing this subcode has no effect.
• The value in subcode 1 results from the node address
) + 0x580.
C14373/2
0x80000000
SDO server channel 2 TX
...
...
...
C14373/10
0x80000000
SDO server channel 10 TX
;
Read access
;
Write access
CINH
PLC STOP
No transfer
Scaling factor: 1
Parameter | Name:
C14374 | CAN SDO client node address
Data type: UNSIGNED_8
Index: 11201
d
= 2BC1
h
Node address of the client assigned to this server (see DS301, V4.02).
Setting range
(min. value | unit | max. value)
1
127
Subcodes
Lenze setting
Information
C14374/1
1
SDO server channel 1 remote client node address
• Subcode 1 contains the basic SDO channel. According
to DS301, V4.02 it does not have this entry. Writing
this subcode has no effect.
• The value of subindex 1 is 0.
C14374/2
1
SDO server channel 2 remote client node address
...
...
...
C14374/10
1
SDO server channel 10 remote client node address
;
Read access
;
Write access
CINH
PLC STOP
No transfer
Scaling factor: 1