Error messages
Possible causes and remedies
62
Lenze · E84AYCEC communication module (POWERLINK) · EDS84AYCEC EN 4.0 - 02/2019
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
10.2
Possible causes and remedies
In this chapter, all error messages of the communication module are listed in numerical order of the
error numbers. Possible causes and remedies and responses to the error messages are described in
detail.
Short overview of the POWERLINK error messages
EPL: Lost connection to 8400 target [0x01bc3100]
EPL: NV Memory: No access [0x01bc5531]
EPL: NV Memory: Read error [0x01bc5532]
EPL: NV Memory: Write error [0x01bc5533]
EPL: Restart after watchdog reset [0x01bc6010]
Response
(Lenze setting printed in bold)
Setting:
not possible
No reaction
System fault
Fault
Trouble
Quick stop by trouble
WarningLocked
Warning
Information
Cause
Remedy
MCI communication to Inverter Drive 8400 is interrup-
ted.
• Inverter Drive 8400 is switched off.
• The communication module is not connected correct-
ly at the MCI slot of the Inverter Drive 8400.
• Switch on Inverter Drive 8400.
• Check screwed connection of the communication mo-
dule at the MCI slot of the Inverter Drive 8400.
• Send the communication module and Inverter Drive
8400 together with a description of the fault to Lenze.
Response
(Lenze setting printed in bold)
Setting:
not possible
No reaction
System fault
Fault
Trouble
Quick stop by trouble
WarningLocked
Warning
Information
Cause
Remedy
Access to parameter set in memory module via standard
device was not successful.
Download application again (including module).
Response
(Lenze setting printed in bold)
Setting:
not possible
No reaction
System fault
Fault
Trouble
Quick stop by trouble
WarningLocked
Warning
Information
Cause
Remedy
Parameter in the memory module could not be read.
Download application again (including module).
Response
(Lenze setting printed in bold)
Setting:
not possible
No reaction
System fault
Fault
Trouble
Quick stop by trouble
WarningLocked
Warning
Information
Cause
Remedy
Parameter in the memory module could not be written. Download application again (including module).
Response
(Lenze setting printed in bold)
Setting:
not possible
No reaction
System fault
Fault
Trouble
Quick stop by trouble
WarningLocked
Warning
Information
Cause
Remedy
Communication module is defective.
Send the communication module and a description of