Lenze E82MV Series Information For The Operator Of The Machine Download Page 2

This documentation applies to 8200 motec inverters as of version

E82MV

xxx

_

x

B001

XX

Vx

2x

Type

Power
(e. g. 551 = 55

×

10

1

W = 0,55 kW)

(e. g. 752 = 75

×

10

2

W = 7,5 kW)

Voltage class
2 = 230 V
4 = 400 V/500 V

Hardware version

Software version

ã

2002 Lenze AG

This documentation contains all information the machine operator require in order
to operate the drive controller of the 8200 motec series installed in your
machine/ system.

If you do not change the content, you are allowed to use the information in this
documentation for your purposes without contacting Lenze.

The information necessary for the project planning of a machine/system can be found in
the Mounting Instructions and Operating Instructions for the 8200 motec frequency
inverters. The Mounting Instructions are included in the scope of delivery, the Operating
Instructions can be ordered at your Lenze representative.

The downloading of the Lenze documentation can be made in the internet as an Adobe
Acrobat

file:

http://www.lenze.de

1.0

03/2002

TD14

efesotomasyon.com - Lenze

Show/Hide Bookmarks

Summary of Contents for E82MV Series

Page 1: ...Information for the operator of the machine system EDK82MVXXX N Global Drive 8200 motec Frequency inverter 0 25 7 5 kW N efesotomasyon com Lenze Show Hide Bookmarks...

Page 2: ...o not change the content you are allowed to use the information in this documentation for your purposes without contacting Lenze The information necessary for the project planning of a machine system...

Page 3: ...50178 apply 4 Installation The controllers must be installed and cooled according to the regulations given in the corresponding Instructions Ensure careful handling and avoid mechanical overload Do n...

Page 4: ...tools to mount or remove belt pulleys and clutches heat generation and cover them with a touch guard Impermissible belt tensions must be avoided technical list The machines are half key balanced The...

Page 5: ...L2 L3 can exceed and destroy the input current limit In case of cyclic mains switching over a longer period of time three minutes have to pass between two starting operations Depending on the controll...

Page 6: ...or monitoring are saved in codes under the menus User and all The codes have numbers 6 and are abbreviated in the text with a C before the number Some codes store the parameters in numerical subcodes...

Page 7: ...8 0 5 V 0 10 V 0 20 mA C0034 Setpoint selection range 0 Application I O X3 1U 0 5 V 0 10 V X3 2U 0 5 V 0 10 V C0007 Fixed configuration of digital inputs 0 E4 E3 E2 E1 C0007 Fixed configuration of dig...

Page 8: ...p q r Hi Hz Lo 1 j g f k i h PS 0988 000 000 a b c d e m n op q r Hi Hz Lo 1 j g f k i h PS 0001 000 000 a b c d e m n op q r Hi Hz Lo 1 j g f k i h PS 0007 ALL 000 000 a b c d e m n op q r Hi Hz Lo 1...

Page 9: ...other are assigned to the same signal source Correct configuration in C0410 Use internal voltage source X3 20 for function modules Standard I O INTERBUS PROFIBUS DP or LECOM B RS485 Bridge between X3...

Page 10: ...transmitter Increase monitoring time under C0357 3 if necessary ce4 a 65 BUS OFF many communication errors occurred Controller has received too many faulty telegrams via system bus and has been disco...

Page 11: ...rings OH3 a 53 PTC monitoring TRIP only generated if C0119 1 4 Motor too hot because of impermissibly high current or frequent and long acceleration processes Check drive selection a y g or 4 PTC not...

Page 12: ...ult Keypad PC 1 rSt a 76 Faulty auto TRIP reset More than 8 fault messages in 10 minutes Depends on the fault message sd5 a 85 Open wire at analog input setpoint range 4 20 mA Current at analog input...