Lenze · E94AYCET communication module (EtherCAT®) · Communication Manual · DMS 10.2 EN · 11/2018 · TD06
123
14
Parameter reference
14.3
Parameters of the communication module for slot MXI2
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C14484
C14489
C14531
Parameter | Name:
C14484 | Active RPDO channel
Data type: UNSIGNED_8
Index: 10091 = 0x276B
This code is for device-internal use only and must not be written to by the user!
Selection of the active RPDO channel
Selection list
Info
0 No RPDO
1 RPDO-1 (I-1600)
... ...
10 RPDO-10 (I-1609)
Subcodes
Lenze setting
Info
C14484/1
1: RPDO-1 (I-1600)
Active RPDO channel
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT
Parameter | Name:
C14489 | No. of RPDO mapping entries
Data type: UNSIGNED_8
Index: 10086 = 0x2766
This code is for device-internal use only and must not be written to by the user!
Subcodes 1 ... 10 specify the number of valid mapping entries of RPDO channels 1 ... 10 (valid subcodes in
...
Setting range
(min. value | unit | max. value)
0
32
Subcodes
Lenze setting
Info
C14489/1
0
No. of mapping entries for RPDO-1
...
0
...
C14489/10
0
No. of mapping entries for RPDO-10
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT
Parameter | Name:
C14531 | Mapping entries TPDO-1
Data type: UNSIGNED_64
Index: 10044 = 0x273C
This code is for device-internal use only and must not be written to by the user!
Subcodes 1 ... 32 specify the mapping for the TPDO channel 1.
• Servo Drives 9400 exclusively support mapping objects with a data length of 8 bits (1 byte) or a multiple of this
value. Incompatible objects must be mapped to variables with a compatible data length.
• The master must have the same mapping entries as the slave.
Structure of the mapping codes (
Value is bit-coded:
Info
Bit 0 Bit 0
... ...
Bit 63 Bit 63
Subcodes
Lenze setting
Info
C14531/1
0
1. mapping entry TPDO-1 (I-1A00.01)
...
...
...
C14531/32
0
32. mapping entry TPDO-1 (I-1A00.20)
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT