Electrical installation − HighLine/StateLine version
Control terminals
Analog input
93
EDS84DPS424 EN 5.0
6.6.2
Analog input
The analog input can be used either as voltage input or as current input.
X50− analog inputs AI, AU
Pin
Signal
Description
Data
Type M12, 5−pole sockets
84DPSO05_5
1
24O
24 V supply of the external sensors
2
AI
Current input
0 ... +20 mA
4 ... +20 mA
3
GA
Reference potential
4
AU
Voltage input
0 ... 10 V
5
Controller
10 V reference voltage (output)
+ 10 V, max. 10 mA