Commissioning
Quick commissioning
143
EDS84DPS424 EN 5.0
8.3
Quick commissioning
Target
For test and demonstration purposes, the load−free motor shall be rotated in best time
with an amount of wiring as little as possible and few settings.
Keypad or setpoint potentiometer
For this simple application, you can choose between two drive control options:
ƒ
Keypad control (
144), i.e. the X400 keypad is used as setpoint source
ƒ
Terminal control (
146), i.e. a setpoint potentiometer connected to the controller
terminals is used as setpoint source
Diagnostics
In addition to the keypad, also use the LEDs on the front of the controller for drive
diagnostics:
ƒ
Two LEDs indicate the device status (DRIVE READY and DRIVE ERROR)
ƒ
Two LEDs indicate the bus status (CAN−RUN and CAN−ERROR)
The LEDs for the bus status are less important during quick commissioning.
Tip!
The handling of the keypad X401 or the diagnosis terminal X401 is described
in the operating instructions. The instructions are supplied with the keypad
and are also included in electronic form on the product CD "L−force Inverter
Drives 8400".