Technical Data
3-2
8250BA0903
3.2 General data / operating conditions
Field
Values
Vibration resistance
Germanischer Lloyd, general conditions (in preparation)
Permissible moisture
Humidity class F without condensation (medium relative
humidity 85
%)
Permissible temperature ranges
during transport :
-25
°
C
¼
+70
°
C
during storage:
-25
°
C
¼
+70
°
C
during operation:
0
°
C
¼
+40
°
C
Permissible installation height h
h
£
1000 m a.m.s.l
without power derating
1000 m a.m.s.l
<
h
£
4000 m a.m.s.l
with power derating
Degree of pollution
VDE 0110 part 2 pollution degree 2
Insulation strength
Overvoltage category III according to VDE 0110
Packing
to DIN 4180
Type of protection
IP10
NEMA 1: Protection against contact
Approvals
CE:
Low-Voltage Directive
EMC Directive in preparation