Inputs of the LS150
The LS150 is supplied with power via the AC input (
). Use a suitable transformer
– we recommend the
Digital plus by Lenz
®
transformer TR100 (art. no. 26000).
AC voltage must be used for the power supply. Do not use a DC
supply; this can damage the LS150.
The power of the transformer used must not exceed 45VA in order to
guarantee a functioning load protection.
Under no circumstances must the transformers TR150 and TR200 be
used !
The track output of the digital system (J,K for
Digital plus by Lenz
®
)
must not be used to supply the LS150 with power!
The LS150 receives the switch information from the track format of the digital
system via the inputs J and K.