EL195DF Parts Identification

FIGURE 1

BURNERS

BLOWER

MOTOR

GAS VALVE AND

MANIFOLD

COMBUSTION AIR

INDUCER

FLUE

COLLAR

TOP CAP

INTEGRATED

CONTROL

PRESSURE SWITCH

ASSEMBLY

AIR INTAKE COLLAR

NOTE − This manual is the property of the homeowner
and must be left with the equipment user.

Notice to Homeowner

This furnace is equipped with safety devices that protect
you and your property. If one or more of these devices is
activated, furnace operation will stop. If your home is left
unattended for an extended period of time, equipment op-
eration must be checked periodically. If this is not possible,

the water supply to the house should be shut off and the

pipes should be drained. This will prevent problems associ-

ated with a NO HEAT condition (frozen pipes, etc.)

CAUTION

Before attempting to perform any service or mainte-
nance, turn the electrical power to unit OFF at the
disconnect switch.

Summary of Contents for EL195DF Series

Page 1: ...by a qualified installer service agency or the gas supplier D Do not try to light any appliance D Do not touch any electrical switch do not use any phone in your building D Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions D If you cannot reach your gas supplier call the fire department D Leave the building immediately GAS FURNACE FIRE OR EXPLOSION H...

Page 2: ... devices that protect you and your property If one or more of these devices is activated furnace operation will stop If your home is left unattended for an extended period of time equipment op eration must be checked periodically If this is not possible the water supply to the house should be shut off and the pipes should be drained This will prevent problems associ ated with a NO HEAT condition f...

Page 3: ...ace or air openings to the area in which the furnace is installed Take care to maintain established clear ances surrounding the furnace 4 DO NOT store chlorine or fluorine products near unit or introduce these products into the combustion air These products can cause furnace corrosion 5 DO NOT draw return air from a room where this fur nace or any other gas appliance ie a water heat er is installe...

Page 4: ... operation EL195DF units are equipped with an ignition system Do not attempt to manually light burners on this furnace Each time the thermostat calls for heat the burners will automatically light The ignitor does not get hot when there is no call for heat on units with this ignition system Operating the Gas Valve Figure 2 1 STOP Read the safety information at the beginning of this section 2 Set th...

Page 5: ...ce venting system vent cap heat exchanger and burners for corro sion deterioration or deposits of debris Remove any ob structions Inspect the furnace for obvious signs of deterioration Inspect the furnace venting system to make sure it is in place physically sound and without holes corrosion or blockage Vent pipe must be clear and free of obstructions and must slope upward away from the furnace In...

Page 6: ...If you suffer from flu like symp toms that are exaggerated at home but seem to sub side while you are away from the house exposure to carbon monoxide could be the cause Your vigilance may pay off in early detection of a problem before either personal injury or property damage occurs Do not hesitate to contact a qualified service technician as an investment in your well being Planned Service You sh...

Page 7: ...e WARNING Product contains fiberglass wool Disturbing the insulation in this product during installation maintenance or repair will expose you to fiberglass wool Breathing this may cause lung cancer Fiberglass wool is known to the State of Cal ifornia to cause cancer Fiberglass wool may also cause respiratory skin and eye irritation To reduce exposure to this substance or for further information c...