Automatically contact Service
If this field is set to
Yes
, and you have enabled Electronic Service Agent (ESA), Lenovo Support will be
notified automatically if the event is generated.
While you wait for Lenovo Support to call, you can perform the recommended actions for the event.
User response
The actions that you should perform to solve the event.
Perform the steps listed in this section in the order shown until the problem is solved. After you perform
all of the actions that are described in this field, if you cannot solve the problem, contact Lenovo Support.
Note:
This list includes error codes and messages that might not apply to this machine type and model.
Below is the list of IMM2 error messages and suggested actions to correct the detected server
problems. For more information about IMM2, see the
Integrated Management Module II User's Guide
IMM Events that automatically notify Support
You can configure the IBM Flex System Manager or the CMM to automatically notify Support (also known as
call home
) if certain types of errors are encountered. If you have configured this function, see the table for
a list of events that automatically notify Support.
Table 39. Events that automatically notify Support
Event ID
Message String
Automatically
Notify Support
40000086-00000000
Test Call Home Generated by user [arg1].
Yes
40000087-00000000
Manual Call Home by user [arg1]: [arg2].
Yes
80010202-0701ffff
Numeric sensor [NumericSensorElementName] going low
(lower critical) has asserted. (CMOS Battery)
Yes
80010902-0701ffff
Numeric sensor [NumericSensorElementName] going
high (upper critical) has asserted. (SysBrd 12V)
Yes
806f0021-2201ffff
Fault in slot [PhysicalConnectorSystemElementName] on
system [ComputerSystemElementName]. (No Op ROM
Space)
Yes
806f0021-2582ffff
Fault in slot [PhysicalConnectorSystemElementName] on
system [ComputerSystemElementName]. (All PCI Error)
Yes
806f0021-2c01ffff
Fault in slot [PhysicalConnectorSystemElementName] on
system [ComputerSystemElementName]. (Mezz Error)
Yes
806f0021-3001ffff
Fault in slot [PhysicalConnectorSystemElementName] on
system [ComputerSystemElementName]. (PCI 1)
Yes
806f0108-0a01ffff
[PowerSupplyElementName] has Failed. (Power Supply 1)
Yes
806f0108-0a02ffff
[PowerSupplyElementName] has Failed. (Power Supply 2)
Yes
806f010c-2001ffff
Uncorrectable error detected for
[PhysicalMemoryElementName] on Subsystem
[MemoryElementName]. (DIMM 1)
Yes
806f010c-2002ffff
Uncorrectable error detected for
[PhysicalMemoryElementName] on Subsystem
[MemoryElementName]. (DIMM 2)
Yes
346
Lenovo System x3650 M4 Installation and Service Guide
Summary of Contents for x3650 M4 BD 5466
Page 1: ...Lenovo System x3650 M4 Installation and Service Guide Machine Type 7915 ...
Page 6: ...iv Lenovo System x3650 M4 Installation and Service Guide ...
Page 176: ...164 Lenovo System x3650 M4 Installation and Service Guide ...
Page 226: ...214 Lenovo System x3650 M4 Installation and Service Guide ...
Page 1042: ...1030 Lenovo System x3650 M4 Installation and Service Guide ...
Page 1200: ...1188 Lenovo System x3650 M4 Installation and Service Guide ...
Page 1204: ...1192 Lenovo System x3650 M4 Installation and Service Guide ...
Page 1212: ...Taiwan BSMI RoHS declaration 1200 Lenovo System x3650 M4 Installation and Service Guide ...
Page 1221: ......
Page 1222: ......