background image

Each ThinkSystem DS Series Expansion Unit ships with two SAS I/O expansion modules. Each  expansion

module provides 12 Gb SAS connectivity to the internal drives, and it has three external 12 Gb SAS x4

ports (Mini-SAS HD SFF-8644 connectors labelled Port A, Port B, and Port C) that are used for

connections to the ThinkSystem DS4200 and for daisy chaining the expansion enclosures between each

other.

The expansion port on the controller module is connected to the Port A on the expansion module, and the

Port C on the expansion module is connected to the Port A on the expansion module in the adjacent

enclosure, and so on.

Note: The Port B on the expansion module is not used.

The expansion enclosure connectivity topology is shown in the following figure.

Figure 7. Expansion unit connectivity topology

The following table lists ordering information for the supported expansion enclosure connectivity options.

Table 7. Expansion unit connectivity options

Description

Part
number

Feature
code

Quantity per one
expansion unit

External MiniSAS HD 8644/MiniSAS HD 8644 0.5M Cable

00YL847

AU16

2*

External MiniSAS HD 8644/MiniSAS HD 8644 1M Cable

00YL848

AU17

2*

External MiniSAS HD 8644/MiniSAS HD 8644 2M Cable

00YL849

AU18

2*

External MiniSAS HD 8644/MiniSAS HD 8644 3M Cable

00YL850

AU19

2*

* One cable per expansion module; two cables are required per each expansion enclosure.

Lenovo ThinkSystem DS4200 Storage Array

12

Summary of Contents for ThinkSystem

Page 1: ...Ds and SAS solid state drives SSDs The DS4200 can be scaled up to 1 84 PB of raw storage capacity The Lenovo ThinkSystem DS4200 enclosures are shown in the following figure Figure 1 Lenovo ThinkSystem DS4200 SFF left and LFF right enclosures Did you know The ThinkSystem DS4200 supports Intelligent Real time Tiering capabilities that help optimize system performance reduce costs and simplify manage...

Page 2: ...tiering SSD read cache and All Flash Array AFA Optional licensed functions including higher number of snapshots for more scalability real time SSD tiering for boosting IOPS performance and asynchronous replication for 24x7 data protection and disaster recovery Intuitive web based GUI for easy system set up and management as well as Command Line Interface CLI Designed for 99 999 availability The Th...

Page 3: ...with automatic drive failure detection and rapid RAID rebuild with global hot spares Redundant hot swappable and customer replaceable hardware components including SFP SFP transceivers controller modules expansion modules power and cooling modules and drives Automated path failover support for the data path between the host and the drives with multipathing software Non disruptive controller firmwa...

Page 4: ...odules Figure 4 ThinkSystem DS4200 with SAS controller modules Rear view The following figure shows the rear view of the ThinkSystem DS4200 with FC iSCSI controller modules Figure 5 ThinkSystem DS4200 with FC iSCSI controller modules Rear view Lenovo ThinkSystem DS4200 Storage Array 4 ...

Page 5: ...s in the system must be of the same type RAID levels RAID 0 1 5 6 and 10 Controller memory 16 GB per system 8 GB per controller module Battery free cache protection with flash memory and supercapacitors Low latency cache mirroring protection for dual controller configurations Drive bays Up to 240 SFF drive bays per storage system 24 SFF drive bays in the DS4200 SFF chassis 24 SFF drive bays in the...

Page 6: ... to 1 84 PB 240x 7 68 TB 2 5 inch SAS SSDs LFF drives Up to 1 2 PB 120x 10 TB 3 5 inch NL SAS HDDs Host connectivity DS4200 SAS controller module 4x 12 Gb SAS host ports Mini SAS HD SFF 8644 DS4200 FC iSCSI controller module 4x SFP SFP host ports with two built in dual port CNCs each port on the same CNC must have the same connectivity type different CNCs might have different connectivity types CN...

Page 7: ...Hot swap parts Controller modules expansion modules SFP SFP transceivers drives PCMs Management interfaces 1 GbE port UTP RJ 45 and serial port Mini USB on the controller modules Web based interface WBI Telnet SSH or Direct Connect USB CLI SNMP and email notifications optional Lenovo XClarity Security features Secure Socket Layer SSL Secure Shell SSH Self encrypting drives SEDs Warranty Three year...

Page 8: ...Controller Unit Japanese documentation 4617A3J LFF models SAS Lenovo ThinkSystem DS4200 LFF SAS Dual Controller Unit US English documentation 4617A41 Lenovo ThinkSystem DS4200 LFF SAS Dual Controller Unit Simplified Chinese documentation 4617A4C Lenovo ThinkSystem DS4200 LFF SAS Dual Controller Unit Japanese documentation 4617A4J Available worldwide except China and Japan Available only in China A...

Page 9: ...s two built in CNCs that have two SFP SFP ports each for a total of four SFP SFP ports per controller module The CNC supports the following storage connectivity protocols depending on the SFP SFP transceiver installed or DAC cables attached 1 Gb iSCSI with 1 GbE RJ 45 SFP optical modules 1 10 Gb iSCSI with 10 GbE SW SFP optical modules with LC connectors 10 Gb iSCSI with 10 GbE SFP DAC cables 4 8 ...

Page 10: ... DAC Cable 90Y9430 A1PJ 8 SAS host connectivity cables Mini SAS HD controller to Mini SAS HD host External MiniSAS HD 8644 MiniSAS HD 8644 0 5M Cable 00YL847 AU16 8 External MiniSAS HD 8644 MiniSAS HD 8644 1M Cable 00YL848 AU17 8 External MiniSAS HD 8644 MiniSAS HD 8644 2M Cable 00YL849 AU18 8 External MiniSAS HD 8644 MiniSAS HD 8644 3M Cable 00YL850 AU19 8 Cable options for 1 Gb iSCSI and Etherne...

Page 11: ...1J Available worldwide except China and Japan Available only in China Available only in Japan The following table lists the CTO base models for the DS Series Expansion Units Table 6 ThinkSystem DS Series Expansion Unit CTO base models Description Machine Type Model Feature code Lenovo ThinkSystem DS Series SFF Expansion Unit 2x PCMs no IOMs 4588 HC2 AU26 Lenovo ThinkSystem DS Series LFF Expansion ...

Page 12: ...osure and so on Note The Port B on the expansion module is not used The expansion enclosure connectivity topology is shown in the following figure Figure 7 Expansion unit connectivity topology The following table lists ordering information for the supported expansion enclosure connectivity options Table 7 Expansion unit connectivity options Description Part number Feature code Quantity per one exp...

Page 13: ... SEDs Lenovo Storage 1 2TB 10K 2 5 SAS HDD SED 01DC412 AU1M 24 2 5 inch 12 Gbps NL SAS hot swap HDDs Lenovo Storage 1TB 7 2K 2 5 NL SAS HDD 01DC442 AU1S 24 Lenovo Storage 2TB 7 2K 2 5 NL SAS HDD 01DC437 AU1R 24 2 5 inch 12 Gbps SAS hot swap SSDs 1 Drive Write per Day DWD Lenovo Storage 3 84TB 1DWD 2 5 SAS SSD 1200 2 01CX632 AV2F 24 Lenovo Storage 3 84TB 1DWD 2 5 SAS SSD PM1633a 01KP065 AVPA 24 Len...

Page 14: ...ement The DS4200 automatically and dynamically moves frequently accessed data to higher performing HDDs in the system without manually creating and managing storage tier policies All Flash Array AFA capability Meets the demand for higher speed storage and provide higher IOPs and bandwidth with lower power usage and total cost of ownership than hybrid or HDD based solutions RAID levels 0 1 5 6 and ...

Page 15: ...rvals Now 1 hour 12 hour 24 hour and does not require high bandwidth network connection For ultimate flexibility DS4200 asynchronous replication interoperates with the ThinkSystem DS2200 and DS6200 as well as Lenovo Storage S2200 and S3200 The asynchronous replication option must be acquired or licensed for both primary local and secondary remote systems The following table lists the Feature on De...

Page 16: ...osoft Internet Explorer Google Chrome or Mozilla Firefox so there is no need for a separate console or plug in Command line interface CLI via Telnet or SSH or through Direct Connect USB Note Direct Connect USB may require device drivers on the connected computer that uses older Windows operating systems Drivers are provided on the Lenovo support site if needed SNMP and e mail notifications Optiona...

Page 17: ...line cord 39Y7917 6212 Denmark Switzerland 10A 230V C13 to IEC 309 P N G 2 8m line cord None 6377 India 10A 250V C13 to IS 6538 2 8m line cord 39Y7927 6269 Israel 10A 250V C13 to SI 32 2 8m line cord 39Y7920 6218 Italy 10A 250V C13 to CEI 23 16 2 8m line cord 39Y7921 6217 Japan 12A 125V C13 to JIS C 8303 2 8m line cord 46M2593 A1RE Korea 12A 250V C13 to KETI 2 8m line cord 39Y7925 6219 South Afric...

Page 18: ...and terms and conditions Not all covered types of warranty service upgrades might be available in a particular country or area For more information about Lenovo warranty service upgrade offerings that are available in your country refer to the Lenovo Enterprise Solutions Configurator LESC http lesc lenovo com The following table explains warranty service definitions for the ThinkSystem DS4200 Tabl...

Page 19: ...der your control regardless of the number of drives that are installed in your Lenovo system In the unlikely event of a drive failure you retain possession of your drive while Lenovo replaces the failed drive part Your data stays safely on your premises in your hands The YourDrive YourData service can be purchased in convenient bundles with Lenovo warranty upgrades and extensions Hardware Installa...

Page 20: ...ation support must be verified through the Lenovo ThinkSystem DS4200 Interoperability Matrix Adapters This section lists the adapters for the following types of storage connectivity SAS connectivity iSCSI connectivity Fibre Channel connectivity SAS connectivity The following table lists currently available SAS adapters for Lenovo servers that are compatible with the ThinkSystem DS4200 SAS storage ...

Page 21: ...es 00JY804 00JY800 Flex System CN4054R 10Gb Virtual Fabric Adapter Requires 90Y3558 00Y3306 Flex System CN4058S 8 port 10Gb Virtual Fabric Adapter Requires 94Y5164 94Y5160 Flex System FoD upgrades required for iSCSI support Flex System CN4052 Virtual Fabric Adapter SW Upgrade FoD For 00JY800 00JY804 Flex System CN4054 Virtual Fabric Adapter Upgrade FoD For 00Y3306 90Y3558 Flex System CN4058S Virtu...

Page 22: ...FC HBA by Emulex 4XB0F28705 ThinkServer LPe16004B M6 L PCIe 16Gb 4 port FC HBA by Emulex 4XB0F28681 ThinkServer LPm16002 M6 L AnyFabric 16Gb 2 Port FC HBA by Emulex 4XB0F28706 ThinkServer HBAs 8 Gb FC ThinkServer LPe12002 PCIe 8Gb 2 Port FC HBA by Emulex 0C19478 ThinkServer LPm15004 M8 L AnyFabric 8Gb 4 Port FC HBA by Emulex 4XB0F28707 Flex System HBAs 16 Gb FC Flex System FC5052 2 port 16Gb FC Ad...

Page 23: ...be used with the ThinkSystem DS4200 in storage solutions Table 18 Ethernet embedded switches for Flex System Description Part number 1 Gb Ethernet iSCSI connectivity Lenovo Flex System EN2092 1Gb Ethernet Scalable Switch 49Y4294 10 Gb Ethernet iSCSI connectivity Lenovo Flex System SI4091 10Gb System Interconnect Module 00FE327 Lenovo Flex System Fabric SI4093 System Interconnect Module 00FM518 Len...

Page 24: ... 48x 32Gb SWL SFPs 2 PS Rail Kit 6415G2A Lenovo ThinkSystem DB400D 32Gb FC Director Up to 192 ports 8U Enterprise SW 6684B2A Lenovo ThinkSystem DB800D 32Gb FC Director Up to 384 ports 14U Enterprise SW 6682B1A For more information see the list of Product Guides in the Rack SAN Switches category http lenovopress com storage switches rack rt product guide The following table lists currently availabl...

Page 25: ...ets that are currently offered by Lenovo that can be used with the DS4200 in storage solutions Table 21 Rack cabinets Description Part number 25U S2 Standard Rack 1000 mm deep 2 sidewall compartments 93072RX 25U Static S2 Standard Rack 1000 mm deep 2 sidewall compartments 93072PX 42U S2 Standard Rack 1000 mm deep 6 sidewall compartments 93074RX 42U 1100mm Enterprise V2 Dynamic Rack 6 sidewall comp...

Page 26: ...004 1U 12 C13 Switched and Monitored 60A 3 Phase PDU with IEC 309 3P Gnd line cord 46M4005 Ultra Density Enterprise PDUs 9x IEC 320 C13 3x IEC 320 C19 outlets Ultra Density Enterprise C19 C13 PDU Module without line cord 71762NX Ultra Density Enterprise C19 C13 PDU 60A 208V 3ph with IEC 309 3P Gnd line cord 71763NU C13 Enterprise PDUs 12x IEC 320 C13 outlets DPI C13 Enterprise PDU without line cor...

Page 27: ...R 16A outlets 55942AX RT2 2kVA 2U Rack or Tower UPS 200 240VAC 8x IEC 320 C13 10A 1x IEC 320 C19 16A outlets 55942KX RT3kVA 2U Rack or Tower UPS 100 125VAC 6x NEMA5 20R 16A 1x NEMA L5 30R 24A outlets 55943AX RT3kVA 2U Rack or Tower UPS 200 240VAC 8x IEC 320 C13 10A 1x IEC 320 C19 16A outlets 55943KX RT5kVA 3U Rack or Tower UPS 200 240VAC 8x IEC 320 C13 10A 2x IEC 320 C19 16A outlets 55945KX RT6kVA...

Page 28: ...llation costs training fees and sales tax If you decide weeks or months later to add to your solution we can consolidate everything into a single invoice Our Premier Client services provide large accounts with special handling services to ensure these complex transactions are serviced properly As a premier client you have a dedicated finance specialist who manages your account through its life fro...

Page 29: ...t are not intended for use in implantation or other life support applications where malfunction may result in injury or death to persons The information contained in this document does not affect or change Lenovo product specifications or warranties Nothing in this document shall operate as an express or implied license or indemnity under the intellectual property rights of Lenovo or third parties...

Page 30: ...n the United States other countries or both AnyFabric Flex System Lenovo XClarity Lenovo RackSwitch System x ThinkServer ThinkSystem The following terms are trademarks of other companies Linux is a trademark of Linus Torvalds in the United States other countries or both Microsoft and Windows are trademarks of Microsoft Corporation in the United States other countries or both Other company product ...