After installing the M.2 backplane and M.2 drive:
1. Install the PCIe adapter retainer. See “Install the PCIe adapter retainer” on page 117.
2. Complete the parts replacement. See “Complete the parts replacement” on page 178.
3. Use the Lenovo XClarity Provisioning Manager to configure the RAID. For more information, see:
http://sysmgt.lenovofiles.com/help/topic/LXPM/RAID_setup.html
TCM/TPM adapter replacement (for China only)
Use this information to remove and install the TCM/TPM adapter (sometimes called a daughter card).
Remove the TCM/TPM adapter (for China only)
Use this information to remove the TCM/TPM adapter.
Ground package before opening”
Before removing the TCM/TPM adapter:
1. If the server is installed in a rack, extend the server from the rack.
2. Remove the server cover. See “Remove the server cover” on page 68.
3. Remove the PCIe adapter retainer. See “Remove the PCIe adapter retainer” on page 116.
To remove the TCM/TPM adapter, complete the following steps:
Step 1. Locate the TCM/TPM connector on the system board.
.
Hardware replacement procedures
131