Step 2. Remove the M.2 drive by rotating it away from the M.2 backplane and pulling away from the
connector at an angle (approximately 30 degrees).
If you are instructed to return the component or optional device, follow all packaging instructions, and use
any packaging materials for shipping that are supplied to you.
Install an M.2 drive in the M.2 backplane
Use this procedure to install an an M.2 drive in the M.2 backplane.
Before installing an M.2 drive in the M.2 backplane:
1. Read the safety information and installation guidelines (see “Safety” on page iii and “Installation
2. Touch the static-protective package that contains the component to any unpainted metal surface on the
server; then, remove it from the package and place it on a static-protective surface.
To install an M.2 drive in the M.2 backplane, complete the following steps:
Step 1. Locate the connector on each side of the M.2 backplane.
Notes:
• Some M.2 backplanes support two M.2 drives. When two drives are installed, align and support
both drives when sliding the retainer forward to secure the drives.
• Install the M.2 drive in slot 0 first.
Figure 71. M.2 drive slots
Table 40. M.2 drive slots
1
Slot 0
2
Slot 1
Step 2. Insert the M.2 drive at an angle (approximately 30 degrees) into the connector and rotate it until the
notch catches on the lip of the retainer; then, slide the retainer forward (toward the connector) to
secure the M.2 drive in the M.2 backplane.
78
ThinkSystem SR850 Maintenance Manual
Summary of Contents for ThinkSystem SR850
Page 1: ...ThinkSystem SR850 Maintenance Manual Machine Type 7X18 and 7X19 ...
Page 8: ...vi ThinkSystem SR850 Maintenance Manual ...
Page 58: ...50 ThinkSystem SR850 Maintenance Manual ...
Page 142: ...134 ThinkSystem SR850 Maintenance Manual ...
Page 166: ...158 ThinkSystem SR850 Maintenance Manual ...
Page 170: ...162 ThinkSystem SR850 Maintenance Manual ...
Page 174: ...Taiwan BSMI RoHS declaration 166 ThinkSystem SR850 Maintenance Manual ...
Page 176: ...168 ThinkSystem SR850 Maintenance Manual ...
Page 182: ...174 ThinkSystem SR850 Maintenance Manual ...
Page 183: ......
Page 184: ...Part Number SP47A24295 Printed in China 1P P N SP47A24295 1PSP47A24295 ...