© Copyright Lenovo 2020
ThinkSystem RAID 940-16i 8GB Flash PCIe Gen4 12Gb Internal Adapter Installation
and User Guide
7
Figure 1
Card Layout for the Thinksystem RAID 940-16i 8GB Flash PCIe Adapter
The following table describes the headers and connectors on the adapter.
Table 2
Headers and Connectors
Connector
Type
Description
J2
Standard edge card connector
The interface between the storage adapter and the host system.
J4
Default serial boot ROM (SBR) header
2-pin connector. Reserved.
J8
On-board serial UART connector
4-pin connector. Reserved.
J5 (C3), J6 (C2),
J17 (C1), J18 (C0)
Storage interface connectors
Four SFF-8654 4-port internal connectors.
Connect the adapter by cable to the storage devices.
J14
Supercap interface connector
9-pin connector.
Connects the adapter to a supercap module.
J25
Power
Power connector.
The following table describes the LEDs on the adapter.
Table 3
LED Designations
LED Type
Description
LED 2 Yellow controller over temperature Stays on solid to indicate that the SAS3916 device temperature sensor is over the
temperature threshold. When the device is in the proper temperature range, this LED is off.
LED 3 Green system heartbeat
Indicates that the SAS3916 RoC ASIC is operating normally. This LED blinks at 1 Hz.
LED 5 Yellow supercap fault
Indicates that the supercap pack is in fault state or is over temperature. This
LED resides on the nonheat-sink side of the board.
LED 6 Green Open NAND Flash Interface
(ONFI) activity
Indicates when the ONFI is active for cache offload or recovery.
Summary of Contents for ThinkSystem RAID 940-16i 8GB Flash PCIe Gen4 12Gb