- 9 -
ThinkSystem RAID 930-24i Adapter Installation and User Guide
1st Edition
Chapter 2: Overview
Safety Characteristics
2.6
Safety Characteristics
All ThinkSystem RAID adapters and HBAs meet or exceed the requirements of UL flammability rating 94 V0. Each bare
board is also marked with the supplier name or trademark, type, and UL flammability rating. For the boards installed in
a PCIe bus slot, all voltages are lower than the Safety Extra Low Voltage (SELV) 42.4V limit.
J10
Global hard disk drive (HDD)
activity LED header
2-pin connector
Connects to an LED that indicates activity on the drives connected to
the adapter.
J11
Global hard disk drive (HDD)
activity LED header
2-pin connector
Connects to an LED that indicates activity on the drives connected to
the adapter.
J14
On-board serial Universal
Asynchronous
Receiver/Transmitter (UART)
connector for the SAS3508
controller
4-pin connector
Reserved for Lenovo debug.
J15
On-board serial Universal
Asynchronous
Receiver/Transmitter (UART)
connector for the 35X36R
expander.
4-pin connector
Reserved for Lenovo debug.
J16
C0, C1 – Quad x4 SAS Port 0
through Port 7 internal
connector
Two SFF-8643 mini-SAS HD-4i internal connectors
Connects the adapter by cable to SAS drives or SATA drives.
J17
C2, C3 – Quad x4 SAS Port 8
through Port 15 internal
connector
Two SFF-8643 mini-SAS HD-4i internal connectors
Connects the adapter by cable to SAS drives or SATA drives.
J18
C4, C5 – Quad x4 SAS Port 16
through Port 23 internal
connector
Two SFF-8643 mini-SAS HD-4i internal connectors
Connects the adapter by cable to SAS drives or SATA drives.
J22
5X36R expander MDIO header
4-pin connector
Reserved for Lenovo debug.
J24
35X36R expander debug
Universal Asynchronous
Receiver/Transmitter (UART)
connector
4-pin connector
Reserved for Lenovo debug.
LED 4
ROC Over-temperature
This yellow LED stays solid on to indicate that the SAS3516 or SAS3508
device temperature sensor is over temperature threshold. When the
device is in the proper temperature range, the LED is off.
LED 2
System heartbeat
This green LED indicates that the SAS3516 or SAS3508 ROC ASIC is
operating normally. This LED blinks at 1 Hz.
LED 3
Dirty cache
This green LED indicates the cache is dirty (not yet saved to the
storage devices).
LED 5
Supercapacitor fault LED.
This yellow LED indicates that the supercapacitor pack is in fault state.
LED 6
Open NAND Flash Interface
(ONFI) activity LED
This green LED indicates when the ONFI interface is active for either
cache offload or recovery.
LED 7
Expander heartbeat LED
This green LED indicates that the expander is operating normally.
Table 1 LEDs, Jumpers, and Connectors (Continued)
Jumper/ Connector
Type
Description