To reset hard disk drives to non-RAID, do the following:
1. Enter the Intel RSTe configuration utility. See “Entering the Intel RSTe configuration utility” on page 72.
2. Press the up and down arrow keys to select
Reset Disks to Non-RAID
. Press Enter to enter the
RESET RAID DATA window.
3. Use the up and down arrow keys and the space key to mark individual hard disk drive to be reset,
and then press Enter to complete the selection.
4. When prompted, press Y to confirm the reset action.
5. If the hard disk drive you reset is part of a RAID volume, the computer might detect that the RAID volume
is degraded. In this case, you are prompted to select a hard disk drive to initiate a rebuild process.
6. Select an available hard disk drive, and then press Enter to initiate the rebuild process.
Note:
Press Esc to cancel a rebuild process and keep the RAID volume in the degraded status. In the
Main Menu window under
DISK/VOLUME INFORMATION
, you will see the status of the RAID volume
is changed to
Degraded
.
Quick RAID setup using the LSI MegaRAID BIOS configuration utility
Notes:
• The LSI MegaRAID SAS adapter and the LSI MegaRAID BIOS configuration utility are only available
on some models.
• The following steps in this section are intended to guide you through a quick setup of basic
RAID functions with the LSI MegaRAID SAS adapter. For advanced setup and configuration
using this adapter, refer to the complete
MegaRAID SAS Software User Guide
that is available at
http://support.lenovo.com/en_US/guides-and-manuals/detail.page?DocID=UM007543.
This section provides information about the following topics:
•
“Installing SATA or SAS hard disk drives” on page 74
•
“Entering the LSI MegaRAID BIOS configuration utility” on page 75
•
“Creating RAID volumes using the LSI MegaRAID BIOS configuration utility” on page 75
•
“Deleting RAID volumes using the LSI MegaRAID BIOS configuration utility” on page 76
•
“Setting the hot spare hard disk drive” on page 76
Installing SATA or SAS hard disk drives
Ensure that your computer has the minimum number of SATA or SAS hard disk drives installed for the
following supported levels of RAID:
• RAID Level 0 - Striped disk array
– A RAID Level 0 hard disk drive group consisting of at least one hard disk drive
– Supported strip size: 8 KB to 1 MB
– Better performance without fault tolerance
• RAID Level 00 - Spanned hard disk drive group with a series of RAID 0 hard disk drive groups
– A RAID Level 00 hard disk drive group consisting of two or four hard disk drives
– Supported strip size: 8 KB to 1 MB
– Better performance without fault tolerance
• RAID Level 1 - Mirrored disk array
– A RAID Level 1 hard disk drive group consisting of two or four hard disk drives
– Improved read performance and 100% redundancy
74
ThinkStation P500 and P700 Hardware Maintenance Manual
Summary of Contents for ThinkStation P500
Page 1: ...ThinkStation P500 and P700 Hardware Maintenance Manual Machine Types 30A6 30A7 30A8 and 30A9 ...
Page 14: ...8 ThinkStation P500 and P700 Hardware Maintenance Manual ...
Page 18: ...12 ThinkStation P500 and P700 Hardware Maintenance Manual ...
Page 19: ...1 2 Chapter 1 Read this first Important safety information 13 ...
Page 20: ...1 2 14 ThinkStation P500 and P700 Hardware Maintenance Manual ...
Page 25: ...1 2 Chapter 1 Read this first Important safety information 19 ...
Page 26: ...1 2 20 ThinkStation P500 and P700 Hardware Maintenance Manual ...
Page 29: ...Chapter 1 Read this first Important safety information 23 ...
Page 39: ...Figure 5 Locating major FRUs and CRUs Chapter 2 Product overview 33 ...
Page 52: ...46 ThinkStation P500 and P700 Hardware Maintenance Manual ...
Page 60: ...54 ThinkStation P500 and P700 Hardware Maintenance Manual ...
Page 66: ...60 ThinkStation P500 and P700 Hardware Maintenance Manual ...
Page 100: ...94 ThinkStation P500 and P700 Hardware Maintenance Manual ...
Page 108: ...102 ThinkStation P500 and P700 Hardware Maintenance Manual ...
Page 216: ...210 ThinkStation P500 and P700 Hardware Maintenance Manual ...
Page 220: ...214 ThinkStation P500 and P700 Hardware Maintenance Manual ...
Page 230: ...224 ThinkStation P500 and P700 Hardware Maintenance Manual ...
Page 231: ......
Page 232: ......