1
2
3
4
5
6
7
Terminal
Voltage
(V
dc)
2
+
0
to
+
14.4
6
Ground
(−)
3.
If
the
voltage
is
less
than
+14.4
V
dc,
the
battery
pack
has
been
discharged.
Note:
Recharging
will
take
at
least
3
hours,
even
if
the
indicator
does
not
turn
on.
If
the
voltage
is
still
less
than
+14.4
V
dc
after
recharging,
replace
the
battery.
4.
If
the
voltage
is
more
than
+14.4
V
dc,
measure
the
resistance
between
battery
terminals
4
and
5.
The
resistance
must
be
4
to
30
K
.
If
the
resistance
is
not
correct,
replace
the
battery
pack.
If
the
resistance
is
correct,
replace
the
system
board.
Checking
the
backup
battery
Do
the
following:
1.
Power
off
the
computer,
and
unplug
the
ac
adapter
from
it.
2.
Turn
the
computer
upside
down.
3.
Remove
the
battery
pack
(see
“1010
Battery
pack”
on
page
56).
4.
Remove
the
backup
battery
(see
“1140
Backup
battery”
on
page
78).
5.
Measure
the
voltage
of
the
backup
battery.
See
the
following
figure.
Red (+)
Black (-)
Wire
Voltage
(V
dc)
Red
+2.5
to
+3.2
Black
Ground
v
If
the
voltage
is
correct,
replace
the
system
board.
v
If
the
voltage
is
not
correct,
replace
the
backup
battery.
v
If
the
backup
battery
discharges
quickly
after
replacement,
replace
the
system
board.
Checkout
guide
32
ThinkPad
®
X60,
X60s,
X61,
and
X61s
Summary of Contents for ThinkPad X60 Tablet
Page 2: ......
Page 3: ...ThinkPad X60 X60s X61 and X61s Hardware Maintenance Manual ...
Page 6: ...iv ThinkPad X60 X60s X61 and X61s ...
Page 8: ...2 ThinkPad X60 X60s X61 and X61s ...
Page 112: ...2 2 continued Removing and replacing a FRU 106 ThinkPad X60 X60s X61 and X61s ...
Page 114: ...3 3 Removing and replacing a FRU 108 ThinkPad X60 X60s X61 and X61s ...
Page 205: ...Trademarks ThinkPad X60 X60s X61 and X61s 199 ...