Rack cabinets

The following table lists the rack cabinets that are offered by Lenovo that can be used with the ThinkAgile

VX Series appliances.

Table 19. Rack cabinets

Description

Part
number

Feature
code

25U S2 Standard Rack (1000 mm deep; 2 sidewall compartments)

93072RX 1042

25U Static S2 Standard Rack (1000 mm deep; 2 sidewall compartments)

93072PX 6690

42U S2 Standard Rack (1000 mm deep; 6 sidewall compartments)

93074RX 1043

42U 1100mm Enterprise V2 Dynamic Rack (6 sidewall compartments)

93634PX A1RC

42U 1100mm Enterprise V2 Dynamic Expansion Rack (6 sidewall compartments)

93634EX

A1RD

42U 1200mm Deep Dynamic Rack (6 sidewall compartments)

93604PX 7649

42U 1200mm Deep Static Rack (6 sidewall compartments)

93614PX 7651

42U Enterprise Rack (1105 mm deep; 4 sidewall compartments)

93084PX 5621

42U Enterprise Expansion Rack (1105 mm deep; 4 sidewall compartments)

93084EX

5622

For more information, see the list of Product Guides in the Rack Cabinets category:

http://lenovopress.com/servers/options/racks#rt=product-guide

Power distribution units

The following table lists the power distribution units (PDUs) that are offered by Lenovo that can be used

with the ThinkAgile VX Series appliances.

Table 20. Power distribution units

Description

Part
number

Feature
code

0U Basic PDUs
0U 36 C13/6 C19 24A/200-240V 1 Phase PDU with NEMA L6-30P line cord

00YJ776

ATZY

0U 36 C13/6 C19 32A/200-240V 1 Phase PDU with IEC60309 332P6 line cord

00YJ777

ATZZ

0U 21 C13/12 C19 32A/200-240V/346-415V 3 Phase PDU with IEC60309 532P6 cord

00YJ778

AU00

0U 21 C13/12 C19 48A/200-240V 3 Phase PDU with IEC60309 460P9 line cord

00YJ779

ATZX

Switched and Monitored PDUs
0U 20 C13/4 C19 Switched and Monitored 24A/200-240V/1Ph PDU w/ NEMA L6-30P cord

00YJ781

AU03

0U 20 C13/4 C19 Switched / Monitored 32A/200-240V/1Ph PDU w/ IEC60309 332P6 cord

00YJ780

AU01

0U 18 C13/6 C19 Sw. / Mon. 32A/200-240/346-415V/3Ph PDU w/ IEC60309 532P6 cord

00YJ782

AU02

0U 12 C13/12 C19 Switched / Monitored 48A/200-240V/3Ph PDU w/ IEC60309 460P9 cord 00YJ783

AU04

1U 9 C19/3 C13 Switched and Monitored DPI PDU (without line cord)

46M4002 5896

1U 9 C19/3 C13 Switched and Monitored 60A 3Ph PDU with IEC 309 3P+Gnd cord

46M4003 5897

1U 12 C13 Switched and Monitored DPI PDU (without line cord)

46M4004 5894

1U 12 C13 Switched and Monitored 60A 3 Phase PDU with IEC 309 3P+Gnd line cord

46M4005 5895

Ultra Density Enterprise PDUs (9x IEC 320 C13 + 3x IEC 320 C19 outlets)
Ultra Density Enterprise C19/C13 PDU Module (without line cord)

71762NX 6050

Ultra Density Enterprise C19/C13 PDU 60A/208V/3ph with IEC 309 3P+Gnd line cord

71763NU 6051

Lenovo ThinkAgile VX5520 Appliance

25

Summary of Contents for ThinkAgile VX5520

Page 1: ...Starting with as few as three nodes to keep your acquisition costs down the VX Series is capable of immense scalability as your needs grow The ThinkAgile VX5520 is a 2U rack mount appliance for storage heavy workloads that is shown in the following figure Figure 1 ThinkAgile VX5520 appliance Did you know The ThinkAgile VX Series appliances are built on industry leading Lenovo ThinkSystem servers t...

Page 2: ...availability with near zero downtime Centralized management with provisioning administering and monitoring virtual resources across multiple hosts and clusters from a centralized interface Rapid workload provisioning simplified data center operations increased business efficiency and decreased CAPEX and OPEX costs VM and data protection with agent less image level virtual machine backups and appli...

Page 3: ...0 front view The following figure shows the rear view of the VX5520 appliance with one drive group Figure 3 VX5520 rear view One drive group The following figure shows the rear view of the VX5520 appliance with two drive groups Figure 4 VX5520 rear view Two drive groups Lenovo ThinkAgile VX5520 Appliance 3 ...

Page 4: ...100 1000 Mb Ethernet systems management port Boot drive 2x 128 GB M 2 non hot swap SSDs RAID 1 I O expansion slots 6x PCIe 3 0 slots configurations with 1 drive group 7 drive bays used Slot 1 PCIe 3 0 x16 not used Slot 3 PCIe 3 0 x8 for the second PCIe network adapter 1 CPU installed Slot 4 PCIe 3 0 x8 for the first PCIe network adapter Slot 5 PCIe 3 0 x16 not used Slot 6 PCIe 3 0 x16 for the seco...

Page 5: ...te Specification Factory integrated models Factory integrated models of the ThinkAgile VX Series appliances are configured by using the Lenovo Enterprise Solutions Configurator LESC http lesc lenovo com During the configuration process you are selecting one of the base Configure to Order CTO models first and then you are adding components processors memory drives and network adapters to the select...

Page 6: ...z Processor 1 2 Intel Xeon Gold 5119T 14C 85W 2 0GHz Processor 1 2 Intel Xeon Gold 5120 14C 105W 2 2GHz Processor 1 2 Intel Xeon Gold 5120T 14C 105W 2 2GHz Processor 1 2 Intel Xeon Gold 5122 4C 105W 3 6GHz Processor 1 2 Intel Xeon Gold 6126 12C 125W 2 6GHz Processor 1 2 Intel Xeon Gold 6128 6C 115W 3 4GHz Processor 1 2 Intel Xeon Gold 6130 16C 125W 2 1GHz Processor 1 2 Intel Xeon Gold 6130T 16C 12...

Page 7: ...MB 2400 MHz 768 GB 9 6 GT s 85W Yes Yes Yes Yes 4114 2 2 3 0 GHz 10 20 13 75 MB 2400 MHz 768 GB 9 6 GT s 85W Yes Yes Yes Yes 4114T 2 2 3 0 GHz 10 20 13 75 MB 2400 MHz 768 GB 9 6 GT s 85W Yes Yes Yes Yes 4116 2 1 3 0 GHz 12 24 16 5 MB 2400 MHz 768 GB 9 6 GT s 85W Yes Yes Yes Yes 4116T 2 1 3 0 GHz 12 24 16 5 MB 2400 MHz 768 GB 9 6 GT s 85W Yes Yes Yes Yes Intel Xeon Gold processors 5115 2 4 3 2 GHz ...

Page 8: ...ntel Xeon Platinum processors 8153 2 0 2 8 GHz 16 32 22 MB 2666 MHz 768 GB 10 4 GT s 125W Yes Yes Yes Yes 8156 3 6 3 7 GHz 4 8 16 5 MB 2666 MHz 768 GB 10 4 GT s 105W Yes Yes Yes Yes 8158 3 0 3 7 GHz 12 24 24 75 MB 2666 MHz 768 GB 10 4 GT s 150W Yes Yes Yes Yes 8160 2 1 3 7 GHz 24 48 33 MB 2666 MHz 768 GB 10 4 GT s 150W Yes Yes Yes Yes 8160M 2 1 3 7 GHz 24 48 33 MB 2666 MHz 1 5 TB 10 4 GT s 150W Ye...

Page 9: ...the specific processor Note Maximum memory speed can be achieved when Max performance mode is enabled in UEFI The following memory protection technologies are supported ECC SDDC for x4 based memory DIMMs ADDDC for x4 based memory DIMMs Gold and Platinum processors only Patrol scrubbing Demand scrubbing The following table lists the memory options that are available for selection Table 6 Memory sel...

Page 10: ...che drives SSDs ThinkSystem 3 5 HUSMM32 400GB Performance SAS 12Gb Hot Swap SSD 1 1 ThinkSystem 3 5 HUSMM32 800GB Performance SAS 12Gb Hot Swap SSD 1 1 ThinkSystem 3 5 HUSMM32 1 6TB Performance SAS 12Gb Hot Swap SSD 1 1 ThinkSystem 3 5 Intel S4600 1 92TB Mainstream SATA 6Gb Hot Swap SSD 1 1 Capacity drives HDDs ThinkSystem 3 5 2TB 7 2K SAS 12Gb Hot Swap 512n HDD 1 6 ThinkSystem 3 5 4TB 7 2K SAS 12...

Page 11: ...he RJ 45 and SFP ports cannot be intermixed in the same appliance that is either RJ 45 or SFP ports can be selected for the appliance but not both port types Also the Intel X710 DA2 and Emulex VFA5 2 network adapters are mutually exclusive The SFP ports require SFP transceivers or direct attach copper DAC cables that should be ordered for the appliance The RJ 45 ports require UTP Category 6 cables...

Page 12: ...enovo 5m Passive SFP DAC Cable 90Y9433 A1PK Active SFP DAC cables for 10 GbE SFP adapters Lenovo 1m Active DAC SFP Cable 00VX111 AT2R Description Part number Feature code The following table lists cables for the 1 10 GbE RJ 45 ports Table 11 Cables for 1 10 GbE RJ 45 ports Description Part number Feature code 0 75m CAT6 Green Cable 00WE123 AVFW 1 0m CAT6 Green Cable 00WE127 AVFX 1 25m CAT6 Green C...

Page 13: ... AC Worldwide and HVDC China only power sources Rack installation The VX5520 appliances ship with a rail kit with or without 2U CMA depending on the rack installation option selected The following table summarizes the features of the rail kits that are available for selection Table 13 Rail kit features summary Feature Tool less Slide Rail Without CMA With 2U CMA CMA Not included Included Rail leng...

Page 14: ...ROBO Standard 25 VM Pack vSphere for ROBO Standard provides remote site server virtualization platform with business continuity and backup features VMware vSphere 6 for Remote Office Branch Office Advanced 25 VM Pack vSphere for ROBO Advanced provides remote site server virtualization platform that offers business continuity and backup with advanced features such as standardization of host configu...

Page 15: ...e vSAN standalone vSAN license options must be selected with the Horizon 7 Standard The quantity of processor based licenses is derived by the configuration tool based on the number of processors selected The quantity of VM based licenses can be specified based on VM requirements VMware License and Subscription options include 3 year or 5 year software support matches the duration of the selected ...

Page 16: ...o Yes No No Operations Visibility No No Yes No No Feature VMware vSphere software edition Standard Enterprise Plus Operations Management Enterprise Plus Standard for ROBO Advanced for ROBO Requires vCenter Server Standard Requires vRealize Operations Standard The following table compares features of the VMware vSAN software editions Table 15 VMware vSAN software editions feature comparison Feature...

Page 17: ... Single Sign On for Application and Desktop Access No Yes Yes Image Management for Physical Desktop No Yes Yes Virtualization Pack for Skype for Business No Yes Yes Session Collaboration No No Yes Real time Application Delivery No No Yes Just in Time Delivery with Instant Clone Technology No No Yes User Profile and Policy Management No No Yes Health Monitoring and Performance Analytics No No Yes C...

Page 18: ... also allows to configure systems management and network settings and to control system power Power on Power off Restart The Virtual Operator Panel can be accessed from the XClarity Mobile App running on the Android or iOS mobile device that is connected to the front USB port with XClarity Controller access See Components and connectors Light path diagnostics The ThinkAgile VX Series appliances in...

Page 19: ... virtualization management tool Deployment of firmware updates to ThinkAgile VX Series appliances from the virtualization management tool Non disruptive server maintenance in clustered environments that reduces workload downtime by dynamically migrating workloads from affected hosts during rolling server updates or reboots Greater service level uptime and assurance in clustered environments during...

Page 20: ...ntifies server power consumption trends and ideal power settings and performs cooling analysis so that you can define and optimize power saving policies Lenovo XClarity Energy Manager offers the following capabilities Monitors room row rack and device levels in the data center Reports vital system information such as power temperature and resource utilization Monitors inlet temperature to locate h...

Page 21: ...0 Hz 1100 W power supplies only 200 240 nominal V AC 50 Hz 60 Hz 180 300 V DC supported in China only Acoustics maximum configuration operating 6 8 bels Vibration Operating 0 21 G rms at 5 Hz to 500 Hz for 15 minutes across 3 axes Non operating 1 04 G rms at 2 Hz to 200 Hz for 15 minutes across 6 surfaces Shock Operating 15 G for 3 milliseconds in each direction positive and negative X Y and Z axe...

Page 22: ...han the standard warranty This is due to local business practices or laws in the specific country Local service teams can assist in explaining country specific terms when needed Examples of country specific warranty terms are second or longer business day parts delivery or parts only base warranty If warranty terms and conditions include onsite labor for repair or replacement of parts Lenovo will ...

Page 23: ...m Storage http pcsupport lenovo com us en solutions ht503310 Lenovo Data Center Services Agreement http support lenovo com us en solutions ht116628 Software maintenance The ThinkAgile VX Series appliances include a three year or five year software support and subscription matches the duration of the selected hardware warranty period that entitles you to submit service requests to troubleshoot VMwa...

Page 24: ...9BAX AT09 Lenovo RackSwitch G7052 Rear to Front 7159CAX AT0A Lenovo RackSwitch G8052 Rear to Front 7159G52 ASY2 10 Gb Ethernet switches 10 GbE host connectivity Lenovo ThinkSystem NE1032 RackSwitch Rear to Front 7159A1X AU3A Lenovo ThinkSystem NE1032T RackSwitch Rear to Front 7159B1X AU38 Lenovo ThinkSystem NE1072T RackSwitch Rear to Front 7159C1X AU36 Lenovo RackSwitch G8124E Rear to Front 7159BR...

Page 25: ...ribution units Description Part number Feature code 0U Basic PDUs 0U 36 C13 6 C19 24A 200 240V 1 Phase PDU with NEMA L6 30P line cord 00YJ776 ATZY 0U 36 C13 6 C19 32A 200 240V 1 Phase PDU with IEC60309 332P6 line cord 00YJ777 ATZZ 0U 21 C13 12 C19 32A 200 240V 346 415V 3 Phase PDU with IEC60309 532P6 cord 00YJ778 AU00 0U 21 C13 12 C19 48A 200 240V 3 Phase PDU with IEC60309 460P9 line cord 00YJ779 ...

Page 26: ... IEC 309 2P Gnd line cord 39Y8940 6004 DPI 63amp 250V Front end PDU with IEC 309 2P Gnd line cord 39Y8935 6006 Universal PDUs 7x IEC 320 C13 outlets DPI Universal 7 C13 PDU with 2 m IEC 320 C19 to C20 rack power cord 00YE443 5950 Line cords for PDUs that ship without a line cord DPI 30a Line Cord NEMA L6 30P 40K9614 6500 DPI 32a Line Cord IEC 309 P N G 40K9612 6502 DPI 32a Line Cord IEC 309 3P N G...

Page 27: ...icated to delivering a positive finance experience for customers like you who want to maximize your purchase power by obtaining the technology you need today protect against technology obsolescence and preserve your capital for other uses We work with businesses non profit organizations governments and educational institutions to finance their entire technology solution We focus on making it easy ...

Page 28: ...le VX Best Recipes http datacentersupport lenovo com us en solutions HT505302 VMware documentation https docs vmware com Lenovo Data Center Support http datacentersupport lenovo com Related product families Product families related to this document are the following ThinkAgile VX Series for VMware vSAN VMware Alliance Hyperconverged Infrastructure Hyperconverged Infrastructure Lenovo ThinkAgile VX...

Page 29: ...ment are not intended for use in implantation or other life support applications where malfunction may result in injury or death to persons The information contained in this document does not affect or change Lenovo product specifications or warranties Nothing in this document shall operate as an express or implied license or indemnity under the intellectual property rights of Lenovo or third part...

Page 30: ...hinkAgile ThinkSystem TruDDR4 The following terms are trademarks of other companies Intel and Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries Linux is a trademark of Linus Torvalds in the United States other countries or both Access Microsoft PowerShell SQL Server SharePoint Skype Windows PowerShell and Windows are trad...

Reviews: