Humidity:
Operating:
ASHRAE Class A4: 8% - 90% (non-condensing); maximum dew point: 24 °C (75 °F)
ASHRAE Class A3: 8% - 85% (non-condensing); maximum dew point: 24 °C (75 °F)
ASHRAE Class A2: 8% - 80% (non-condensing); maximum dew point: 21 °C (70 °F)
Storage: 8% - 90% (non-condensing)
Electrical:
100 - 127 (nominal) V AC; 50 Hz / 60 Hz (except 750 W Titanium, 1600 W, and 2000 W power
supplies)
200 - 240 (nominal) V AC; 50 Hz / 60 Hz
180 - 300 V DC (supported in China only)
Acoustics (maximum configuration, operating):
HX2320-E: 6.5 bels
HX2720-E: 6.8 bels
Vibration:
Operating: 0.21 G rms at 5 Hz to 500 Hz for 15 minutes across 3 axes
Non-operating: 1.04 G rms at 2 Hz to 200 Hz for 15 minutes across 6 surfaces
Shock:
Operating: 15 G for 3 milliseconds in each direction (positive and negative X, Y, and Z axes)
Non-operating:
12 kg - 22 kg: 50 G for 152 in./sec velocity change across 6 surfaces
23 kg - 31 kg: 35 G for 152 in./sec velocity change across 6 surfaces
The following table lists the maximum system power load, rated inlet current, and system heat output
based on the power supply and source voltage.
Table 22. Rated system power, inlet current, and system heat output
Power supply
Source voltage
Maximum power
load per system
(two power supplies)
Rated current
per inlet
System
heat output
550 W AC Platinum
100 - 127 V AC
722 W
6.2 A
2463 BTU/hour
200 - 240 V AC
704 W
3 A
2402 BTU/hour
180 - 300 V DC
702 W
2.5 A
2395 BTU/hour
750 W AC Platinum
100 - 127 V AC
984 W
8.4 A
3357 BTU/hour
200 - 240 V AC
958 W
4.1 A
3269 BTU/hour
180 - 300 V DC
958 W
3.5 A
3269 BTU/hour
750 W AC Titanium
200 - 240 V AC
949 W
4.1 A
3238 BTU/hour
180 - 300 V DC
948 W
3.5 A
3235 BTU/hour
1600 W AC Platinum
200 - 240 V AC
2068 W
8.7 A
7056 BTU/hour
180 - 300 V DC
2024 W
7.3 A
6906 BTU/hour
2000 W AC Platinum
200 - 240 V AC
2610 W
11 A
8905 BTU/hour
180 - 300 V DC
2597 W
9.2 A
8861 BTU/hour
Regulatory compliance
Lenovo ThinkAgile HX2320-E and HX2720-E Appliances
23