Checkout procedure
The checkout procedure is the sequence of tasks that you should follow to diagnose a problem in the server.
About the checkout procedure
Before you perform the checkout procedure for diagnosing hardware problems, review the following
information:
• Read the safety information that begins on [age “Safety” on page v.
• The Dynamic System Analysis (DSA) provides the primary methods of testing the major components of
the server, such as the system board, Ethernet controller, keyboard, mouse (pointing device), serial
ports, and hard disk drives. You can also use them to test some external devices. If you are not sure
whether a problem is caused by the hardware or by the software, you can use the diagnostic programs to
confirm that the hardware is working correctly.
• When you run DSA, a single problem might cause more than one error message. When this happens,
correct the cause of the first error message. The other error messages usually will not occur the next
time you run DSA.
Important:
If multiple error codes or light path diagnostics LEDs indicate a microprocessor error, the
error might be in the microprocessor or in the microprocessor socket. See “Microprocessor problems” on
page 145 for information about diagnosing microprocessor problems.
• Before you run DSA, you must determine whether the failing server is part of a shared hard disk drive
cluster (two or more servers sharing external storage devices). If it is part of a cluster, you can run all
diagnostic programs except the ones that test the storage unit (that is, a hard disk drive in the storage
unit) or the storage adapter that is attached to the storage unit. The failing server might be part of a
cluster if any of the following conditions is true:
– You have identified the failing server as part of a cluster (two or more servers sharing external storage
devices).
– One or more external storage units are attached to the failing server and at least one of the attached
storage units is also attached to another server or unidentifiable device.
– One or more servers are located near the failing server.
Important:
If the server is part of a shared hard disk drive cluster, run one test at a time. Do not run
any suite of tests, such as “quick” or “normal” tests, because this might enable the hard disk drive
diagnostic tests.
• If the server is halted and a POST error code is displayed, see Appendix B “UEFI/POST diagnostic codes”
on page 953. If the server is halted and no error message is displayed, see “Troubleshooting by symptom”
on page 140 and “Solving undetermined problems” on page 160.
• For information about power-supply problems, see “Solving power problems” on page 157, “Power
problems” on page 149, and “Power-supply LEDs” on page 131.
• For intermittent problems, check the event log; see “Event logs” on page 135 and Appendix C “DSA
diagnostic test results” on page 977.
Performing the checkout procedure
Use this information to perform the checkout procedure.
To perform the checkout procedure, complete the following steps:
126
Lenovo System x3650 M4 HD Installation and Service Guide
Summary of Contents for System x3650 M4 HD
Page 1: ...Lenovo System x3650 M4 HD Installation and Service Guide Machine Type 5460 ...
Page 6: ...iv Lenovo System x3650 M4 HD Installation and Service Guide ...
Page 134: ...122 Lenovo System x3650 M4 HD Installation and Service Guide ...
Page 178: ...166 Lenovo System x3650 M4 HD Installation and Service Guide ...
Page 190: ...178 Lenovo System x3650 M4 HD Installation and Service Guide ...
Page 314: ...302 Lenovo System x3650 M4 HD Installation and Service Guide ...
Page 964: ...952 Lenovo System x3650 M4 HD Installation and Service Guide ...
Page 988: ...976 Lenovo System x3650 M4 HD Installation and Service Guide ...
Page 1146: ...1134 Lenovo System x3650 M4 HD Installation and Service Guide ...
Page 1150: ...1138 Lenovo System x3650 M4 HD Installation and Service Guide ...
Page 1158: ...Taiwan BSMI RoHS declaration 1146 Lenovo System x3650 M4 HD Installation and Service Guide ...
Page 1167: ......
Page 1168: ......