0U PDU support
Limited support.
Read the notes at the
bottom.
Limited support.
Read the notes at the
bottom.
Limited support.
Read the notes at the
bottom.
Limited support.
Read the notes at the
bottom.
Mounting holes
Square, round, or
threaded
Square or round
Square or round
Square or round
Thickness of
mounting flanges
2 mm (0.08 inches) –
4.65 mm (0.18 inches)
2 mm (0.08 inches) –
4 mm (0.16 inches)
2 mm (0.08 inches) –
3.3 mm (0.13 inches)
2 mm (0.08 inches) –
4 mm (0.16 inches)
Distance between
front and rear
mounting flanges
617 mm (24.29
inches) – 812 mm
(31.97 inches)
595 mm (23.43
inches) – 746 mm
(29.37 inches)
617 mm (24.29
inches) – 812 mm
(31.97 inches)
609.6 mm (24 inches)
– 914.4 mm (36
inches)
Rail length
(measured when
mounted on the
rack, starting from
the front surface of
the front mounting
flange to the rear
most point of the
rail)
836.8 mm (32.94
inches)
755 mm (29.72
inches)
833.5 mm (32.81
inches)
728.1 mm (28.6
inches)
Notes:
• If you want to install the rails and a 0U PDU into the same rack, the rack must meet the following height
and depth requirements:
– 42U or higher
– For 00MW239 and 00MV369 rails: at least 1000-mm (39.37-inch) deep
– For 00KA500 and 00KA606 rails: at least 1100-mm (43.31-inch) deep if no CMA is to be installed; at
least 1200-mm (47.24-inch) deep if a CMA is to be installed
• The option part numbers might change.
What your server offers
This section introduces features and technologies the server uses and provides.
•
Dynamic System Analysis (DSA)
The server comes with the Dynamic System Analysis (DSA) Preboot diagnostic program stored in the
integrated USB memory on the server. DSA collects and analyzes system information to aid in diagnosing
server problems, as well as offering a rich set of diagnostic tests of the major components of the server.
DSA creates a DSA log, which is a chronologically ordered merge of the system-event log (as the IPMI
event log), the Integrated Management Module 2.1 (IMM2.1) chassis event log (as the ASM event log),
and the operating-system event logs. You can send the DSA log as a file to Lenovo Support or view the
information as a text file or Hypertext Markup Language (HTML) file.
•
Features on Demand
If a Features on Demand feature is integrated in the server or in an optional device that is installed in the
server, you can purchase an activation key to activate the feature. For information about Features on
Demand, see https://fod.lenovo.com/lkms.
.
The Lenovo System x3550 M5 server
11
Summary of Contents for System x3550 M5
Page 1: ...Lenovo System x3550 M5 Installation and Service Guide Machine Type 8869 ...
Page 6: ...iv Lenovo System x3550 M5 Installation and Service Guide ...
Page 66: ...52 Lenovo System x3550 M5 Installation and Service Guide ...
Page 298: ...284 Lenovo System x3550 M5 Installation and Service Guide ...
Page 1120: ...1106 Lenovo System x3550 M5 Installation and Service Guide ...
Page 1124: ...1110 Lenovo System x3550 M5 Installation and Service Guide ...
Page 1132: ...Taiwan BSMI RoHS declaration 1118 Lenovo System x3550 M5 Installation and Service Guide ...
Page 1134: ...1120 Lenovo System x3550 M5 Installation and Service Guide ...
Page 1142: ...1128 Lenovo System x3550 M5 Installation and Service Guide ...
Page 1143: ......
Page 1144: ......