background image

I/O expansion options

The server supports up to seven PCIe 3.0 slots: Four slots (1 - 4) when one CPU is installed or seven slots

when two CPUs are installed. The following slot form factors are available:

Slot 1: PCIe 3.0 x8 (x8 wired); full-height, half-length
Slot 2: PCIe 3.0 x16 (x8 wired); full-height, full-length
Slot 3: PCIe 3.0 x16 (x16 wired); full-height, full-length
Slot 4: PCIe 3.0 x8 (x8 wired); full-height, full-length
Slot 5: PCIe 3.0 x8 (x8 wired); full-height, half-length (requires second processor)
Slot 6: PCIe 3.0 x16 (x16 wired); full-height, full-length (requires second processor)
Slot 7: PCIe 3.0 x16 (x16 wired) full-height, full-length (requires second processor)

Slots 3 and 6 support double-wide GPUs

The COM Port Bracket, part number 00KC332, is used for making an external serial port available at the

rear of the server. This option includes the bracket and the cable. The COM Port option is mounted in one

of the PCIe slots and that PCIe slot cannot be used. The following table lists the PCIe slot options.

Table 22. System x3500 M5 COM Port Kit ordering information

Part number

Feature
code

Description

Maximum
supported

00KC332

ARZ0

System x3500 M5 COM Port Kit

1

Network adapters

The x3500 M5 supports four integrated Gigabit Ethernet ports with the following features:

A Broadcom BCM5719 chip
Four Gigabit Ethernet ports
NIC Teaming (load balancing and failover)
Ethernet features:

Compliant with 1 Gb Ethernet IEEE 802.3, 802.3u, and 802.3ab PHY specifications

Integrated PHY for 10/100/1000 Mbps for multispeed, full, and half-duplex auto-negotiation

Automatic MDI crossover

IEEE 802.3x-compliant flow control support

IEEE 1588 protocol and 802.1AS time synchronization implementation

IEEE802.3az - Energy Efficient Ethernet (EEE)

I/O Virtualization features:

I/O Virtualization support for VMware NetQueue and Microsoft virtual machine queue (VMQ)

Function Level Reset (FLR)

IEEE 802.1q Virtual Local Area Network (VLAN) tagging support

Stateless offload and performance features:

TCP, IP, and User Datagram Protocol (UDP) checksum offload

TCP segmentation offload (TCO)

Large Send Offload (LSO)

Receive Side Scaling (RSS) and Transmit Side Scaling (TSS)

Message Signal Interrupt (MSI) and Message Signal Interrupt Extension (MSI-X) support

Support for jumbo frames up to 9600 bytes

The following table lists other supported network adapters.

Lenovo System x3500 M5

29

Summary of Contents for System x3500 M5 Type 5464

Page 1: ...iness critical workloads cloud computing virtualization virtual desktop big data analytics SAP applications database management point of sale Figure 1 shows the System x3500 M5 Figure 1 The Lenovo System x3500 M5 Did you know The x3500 M5 offers a flexible scalable design and simple upgrade path to 32 HDDs with up to seven PCIe 3 0 slots and up to 1 5 TB of memory The onboard Ethernet solution pro...

Page 2: ...s including databases and enterprise resource planning Up to 2133 MHz memory speeds with two DIMMs per channel that are running at 2133 MHz to help maximize system performance Up to 1 5 TB of memory capacity with 64 GB load reduced DIMMs LRDIMMs The 12 Gbps SAS internal storage connectivity doubles the data transfer rate compared to 6 Gb SAS solutions to maximize performance of storage I O intensi...

Page 3: ...etup configuration and updates and simplifies error handling Two integrated Trusted Platform Modules TPMs enable advanced cryptographic functionality such as digital signatures and remote attestation System x Trusted Platform Assurance an exclusive set of System x security features and practices establishes a foolproof security foundation for workloads by delivering firmware that is securely built...

Page 4: ...rgy compared to 1 35 V DDR3 DIMMs SSDs use as much as 80 less power than traditional spinning 2 5 inch HDDs The server uses hexagonal ventilation holes which is a part of Calibrated Vectored Cooling technology Hexagonal holes can be grouped more densely than round holes which provides more efficient airflow through the system IBM Systems Director Active Energy Manager provides advanced data center...

Page 5: ...Figure 3 Rear view of the System x3500 M5 The following figure shows the locations of key components inside the server Figure 4 Inside view of the System x3500 M5 Lenovo System x3500 M5 5 ...

Page 6: ...r SSDs Up to 6x 3 5 inch hot swap HDDs 16x 2 5 inch hot swap drives HDDs SSDs Up to 6x 3 5 inch simple swap SATA HDDs Additional drive bays for the above configurations Two 5 25 inch drive bays for optical drives Maximum internal storage 122 9 TB with 32x 3 84TB 2 5 inch SAS hot swap SSDs 96 TB with 12x 8TB 3 5 inch NL SAS or NL SATA hot swap HDDs 38 4 TB with 32x 1 2TB 2 5 inch SAS hot swap HDDs ...

Page 7: ...ives power supplies and fans Systems management UEFI IMM2 1 that is based on Renesas SH7758 Predictive Failure Analysis light path diagnostics panel on the front of the server with optional upgrade kit Automatic Server Restart ToolsCenter Systems Director and Active Energy Manager Optional IMM Advanced Upgrade software feature for remote presence Security features Power on password administrator s...

Page 8: ...v3 6C 2 4GHz 15MB 1866MHz 85W 1x 16 GB M1215 6x 3 5 inch HS 12 Open 4 7 4 DVD 1x 550 W HS 2 5464 D2x 1x E5 2630 v3 8C 2 4GHz 20MB 1866MHz 85W 1x 16 GB M1215 8x 2 5 inch HS 32 Open 4 7 4 DVD 1x 550 W HS 2 5464 G2x 1x E5 2650 v3 10C 2 3GHz 25MB 2133MHz 105W 1x 16 GB M5210 1GB Flash 8x 2 inch HS 32 Open 4 7 4 DVD 1x 750 W HS 2 5464 H2x 1x E5 2670 v3 12C 2 3GHz 30MB 2133MHz 120W 1x 16 GB M5210 2GB Fla...

Page 9: ...r 2x 550W 5464 E4G Tower 1x E5 2620 v3 6C 2 4GHz 15MB 1866MHz 85W 1x 8 GB M5210 1GB Flash 8x 2 5 inch HS 32 3x 300GB 10K SAS 4 7 Multi burner 2x 750W 5464 E5G Tower 1x E5 2640 v3 8C 2 6GHz 20MB 1866MHz 90W 1x 16 GB M5210 2GB Flash 8x 2 5 inch HS 32 Open 4 7 Multi burner 2x 750W Latin America Brazil 5464 EFx Tower 1x E5 2609 v3 6C 1 9GHz 15MB 1600MHz 85W 1x 8 GB M5210 1GB Flash Cap 8x 2 5 inch HS 3...

Page 10: ...50 v3 10C 2 3GHz 25MB 2133MHz 105W 1x 16 GB M5210 8x 2 5 inch HS 32 Open 4 7 Open 1x 750W Europe Middle East and Africa EMEA 5464 K1G Tower 1x E5 2620 v3 6C 2 4GHz 15MB 1866MHz 85W 1x 16 GB M5210 2GB Flash 8x 2 5 inch HS 32 Open 4 7 Multi burner 1x 550W 5464 K2G Tower 1x E5 2603 v3 6C 1 6GHz 15MB 1600MHz 85W 1x 8 GB M1215 RAID 5 6x 3 5 inch HS 12 Open 4 7 Open 1x 550W 5464 K3G Tower 1x E5 2603 v3 ...

Page 11: ...3MHz 75W 81Y7118 A5CD A5MU Intel Xeon E5 2650 v3 10C 2 3GHz 25MB 2133MHz 105W G2x G3x 81Y7121 A5CG A5MX Intel Xeon E5 2650L v3 12C 1 8GHz 30MB 2133MHz 65W 00MW034 ASU6 ASUH Intel Xeon E5 2658 v3 12C 2 2GHz 30MB 2133MHz 105W 00MU330 ASLU ASLX Intel Xeon E5 2660 v3 12C 2 3GHz 30MB 2133MHz 105W 00MU331 ASLV ASLY Intel Xeon E5 2667 v3 8C 3 2GHz 20MB 2133MHz 135W 81Y7119 A5CE A5MV Intel Xeon E5 2670 v3...

Page 12: ...MHz LP RDIMM 24 12 per CPU LRDIMMs 2133 MHz 46W0800 A5B9 32GB TruDDR4 Memory 4Rx4 1 2V PC417000 CL15 2133MHz LP LRDIMM 24 12 per CPU 95Y4812 A5UK 64GB TruDDR4 Memory 4Rx4 1 2V PC4 17000 CL15 2133MHz LP LRDIMM 24 12 per CPU The server supports up to 12 DIMMs when one processor is installed and up to 24 DIMMs when two processors are installed Each processor has four memory channels there are three D...

Page 13: ...supported DIMMs Tables cells that are highlighted with a gray background indicate when the number of DIMMs per channel still allows the DIMMs to operate at a rated speed Table 7 Maximum memory speeds DIMM specification RDIMM LRDIMM Rank Single rank Dual rank Quad rank Part numbers 46W0784 4 GB 46W0788 8 GB 46W0792 8 GB 46W0796 16 GB 95Y4808 32 GB 46W0800 32 GB 95Y4812 64 GB Rated speed 2133 MHz 21...

Page 14: ...simple swap hard disk drives 6 Gb SATA onboard connectors 6x 3 5 inch simple swap hard disk drives 1 adapter Note A configuration of 12 simple swap drives is not supported The following drive type mixing rules apply Hot swap SATA HDDs and hot swap SAS HDDs can be intermixed on the same backplane but cannot be intermixed in the same RAID array Hot swap SATA HDDs and hot swap SAS HDDs can be intermi...

Page 15: ... SAS 6x 3 5 inch hot swap drives Supported by M5210 M1215 or N2215 C3x C4x 2 A5UM System x3500 M5 3 5 inch Simple Swap 6x 3 5 inch simple swap drives Connections to onboard SATA ports 1 A5D2 System x3500 M5 3 5 inch Simple Swap 6x 3 5 inch simple swap drives Connections to RAID controller 1 Feature code Name Models where used Maximum supported The following table list the available hot swap drive ...

Page 16: ...3 6x 3 5 inch Hot Swap SAS SATA Upgrade Kit for 22 HDDs Intermix For existing configurations with 16x 2 5 inch drives Adds 6x 3 5 inch hot swap drives Same backplane as feature A5D5 00AL544 8x 2 5 inch Hot Swap SAS SATA Upgrade Kit for 14 HDDs Intermix For existing configurations with 6x 3 5 inch drives Adds 8x 2 5 inch hot swap drives Same backplane as feature A5D4 00KG037 8x 2 5 inch Hot Swap SA...

Page 17: ...0 ServeRAID M1215 and N2215 host bus adapter Figure 6 Configurations of 2 5 inch drives with one RAID adapter The following figure shows how models with eight 2 5 inch drive bays can be upgraded to a total of 32 drive bays that use two RAID controller for added performance Supported adapters are the ServeRAID M5210 ServeRAID M1215 and N2215 host bus adapter Figure 7 Configurations of 2 5 inch driv...

Page 18: ...host bus adapter Figure 8 Configurations of 3 5 inch drives For configure to order configurations the server also supports simple swap 3 5 inch drives The simple swap drives can be connected to the 6 Gb SATA ports on the system board of the server or to a RAID controller Only six 3 5 inch drives are supported a configuration of 12 simple swap drives is not supported Figure 9 Simple swap 3 5 inch d...

Page 19: ...hown in the following figure The 3 5 inch drives must be connected to a separate RAID adapter Figure 10 Combinations of 2 5 inch and 3 5 inch drive bays from a 2 5 inch base The following figure shows the upgrade path from models with 3 5 inch drives Figure 11 Combinations of 2 5 inch and 3 5 inch drive bays from a 3 5 inch base Lenovo System x3500 M5 19 ...

Page 20: ...n Demand upgrades for the M5210 47C8708 A3Z6 ServeRAID M5200 Series Zero Cache RAID 5 Upgrade 1 47C8706 A3Z5 ServeRAID M5200 Series RAID 6 Upgrade 1 47C8710 A3Z7 ServeRAID M5200 Series Performance Accelerator 1 47C8712 A3Z8 ServeRAID M5200 Series SSD Caching Enabler 1 Requires cache memory upgrade 47C8656 47C8660 47C8664 or 47C8668 Features on Demand FoD upgrades for ServeRAID adapters are applied...

Page 21: ...D SafeStore with RAID 5 upgrade Supports 1 GB non backed cache or 1 GB 2 GB or 4 GB flash backed cache PCIe 3 0 x8 host interface Based on the LSI SAS3108 12 Gbps ROC controller The N2215 SAS SATA HBA has the following specifications Eight internal 12 Gbps SAS SATA ports Up to 12 Gbps throughput per port Two x4 HD mini SAS internal connectors SFF 8643 Supports connections to SAS SATA HDDs and SSDs...

Page 22: ...0 AT8C 1 2TB 10K 12Gbps SAS 2 5 G3HS HDD 32 00NA251 ASBH 900GB 10K 12Gbps SAS 2 5 G3HS 512e HDD 32 00NA241 ASBF 600GB 10K 12Gbps SAS 2 5 G3HS 512e HDD 32 00NA261 ASBK 1 2TB 10K 12Gbps SAS 2 5 G3HS 512e HDD 32 00NA271 ASBM 1 8TB 10K 12Gbps SAS 2 5 G3HS 512e HDD 32 2 5 inch hot swap HDDs 12 Gb SAS 15K 00WG660 AT84 300GB 15K 12Gbps SAS 2 5 G3HS HDD 32 00WG665 AT85 600GB 15K 12Gbps SAS 2 5 G3HS HDD 32...

Page 23: ...AJ136 A4TW 500GB 7 2K 6Gbps NL SATA 2 5 G3HS HDD 32 00AJ141 A4TX 1TB 7 2K 6Gbps NL SATA 2 5 G3HS HDD 32 00NA526 AT81 2TB 7 2K 6Gbps NL SATA 2 5 G3HS 512e HDD 32 Table 13 2 5 inch hot swap 12 Gb SAS SATA SSDs Part number Feature Description Maximum supported 2 5 inch hot swap SSDs 12 Gb SAS Enterprise Performance 10 DWPD 00FN379 AS7C 200GB 12G SAS 2 5 MLC G3HS Enterprise SSD 32 00FN389 AS7E 400GB 1...

Page 24: ...577 120GB SATA 2 5 MLC G3HS Enterprise Value SSD 32 00AJ400 A578 240GB SATA 2 5 MLC G3HS Enterprise Value SSD 32 00AJ405 A579 480GB SATA 2 5 MLC G3HS Enterprise Value SSD 32 00AJ410 A57A 800GB SATA 2 5 MLC G3HS Enterprise Value SSD 32 2 5 inch hot swap SSDs 6 Gb SATA Enterprise Entry 3 DWPD 00WG620 AT93 S3510 120GB Enterprise Entry SATA G3HS 2 5 SSD 32 00WG625 AT94 S3510 240GB Enterprise Entry SAT...

Page 25: ... Gb NL SATA 81Y9786 A22Y 500GB 7 2K 6Gbps NL SATA 3 5 G2HS HDD 12 81Y9790 A22P 1TB 7 2K 6Gbps NL SATA 3 5 G2HS HDD 12 81Y9794 A22T 2TB 7 2K 6Gbps NL SATA 3 5 G2HS HDD 12 81Y9798 A22S 3TB 7 2K 6Gbps NL SATA 3 5 G2HS HDD 12 49Y6002 A3W9 4TB 7 2K 6Gbps NL SATA 3 5 G2HS HDD 12 00FN113 A5VD 2TB 7 2K 6Gbps NL SATA 3 5 G2HS 512e HDD 12 00FN143 A5VH 4TB 7 2K 6Gbps NL SATA 3 5 G2HS 512e HDD 12 00FN173 A5VM...

Page 26: ... 3 5 inch hot swap SSDs 6 Gb SATA Enterprise Mainstream 3 5 DWPD 00AJ435 A57F 120GB SATA 3 5 MLC HS Enterprise Value SSD 12 00AJ445 A57H 480GB SATA 3 5 MLC HS Enterprise Value SSD 12 3 5 inch hot swap SSDs 6 Gb SATA Enterprise Entry 3 DWPD 00YC420 AT8Y 960GB Enterprise Entry SATA HS 3 5 SSD 12 Table 19 3 5 inch simple swap 6 Gb SAS SATA HDDs Part number Feature Description Maximum supported 3 5 in...

Page 27: ... LTO Ultrium Gen 6 Internal SAS Tape Drive 2 Media 46W6589 A3S6 LTO Ultrium Gen 6 Single Media 2 6 TB native capacity 46C5367 5708 RDX 320GB Cartridge 46C5368 5709 RDX 500GB Cartridge 81Y3647 A1VL RDX 1TB Cartridge The LTO5 and LTO6 are supported with addition of the the N2215 SAS SATA HBA connectivity is via a 12Gb SAS Cable for LTO Tape drive which is included with the tape drive option part num...

Page 28: ... 25 inch drive bay The Half High SATA DVD ROM drive supports the following media and speeds for reading CD ROM 48X CD DA DAE 40X CD R 48X CD RW 40X DVD ROM single layer 16X DVD ROM dual layer 12X DVD R 4 7 GB 16X DVD R DL 12X DVD R 16X DVD R DL 12X DVD RW 4 7 GB 12X DVD RW 12X DVD RAM 4 7 9 4 GB 6X The Half High SATA multiburner drive supports the same media and speeds for reading as HH DVD ROM In...

Page 29: ...er Feature code Description Maximum supported 00KC332 ARZ0 System x3500 M5 COM Port Kit 1 Network adapters The x3500 M5 supports four integrated Gigabit Ethernet ports with the following features A Broadcom BCM5719 chip Four Gigabit Ethernet ports NIC Teaming load balancing and failover Ethernet features Compliant with 1 Gb Ethernet IEEE 802 3 802 3u and 802 3ab PHY specifications Integrated PHY f...

Page 30: ... 7 90Y4600 A3MR QLogic 8200 Dual Port 10GbE SFP VFA 4 7 00Y5624 A3MT QLogic 8200 VFA FCoE iSCSI License FoD Features on Demand upgrade for 90Y4600 4 7 47C9952 A47H Solarflare SFN5162F 2x10GbE SFP Performant Adapter 4 7 47C9977 A522 Solarflare SFN7122F 2x10GbE SFP Flareon Ultra 4 7 1 Gb Ethernet 42C1780 2995 Broadcom NetXtreme 2xGbE BaseT Adapter 4 7 90Y9370 A2V4 Broadcom NetXtreme I Dual Port GbE ...

Page 31: ...GbE SFP adapters 46C3447 5053 Lenovo 10GBASE SR SFP Transceiver Per adapter port 49Y4216 0069 Brocade 10Gb SFP SR Optical Transceiver Per adapter port 49Y4218 0064 QLogic 10Gb SFP SR Optical Transceiver Per adapter port 10 GbE SFP DAC cables for 10 GbE SFP adapters 00D6288 A3RG Lenovo 0 5m Passive SFP DAC Cable Per adapter port 90Y9427 A1PH Lenovo 1m Passive SFP DAC Cable Per adapter port 00AY764 ...

Page 32: ...2226 N2225 Adapter type RAID adapter SAS HBA SAS HBA Part number 00AE938 00AE916 00AE912 Form factor Low profile Low profile Low profile Controller chip LSI SAS3108 LSI SAS3008 LSI SAS3008 Host interface PCIe 3 0 x8 PCIe 3 0 x8 PCIe 3 0 x8 Port interface 12 Gbps SAS 12 Gbps SAS 12 Gbps SAS Number of external ports 8 16 8 External port connectors 2x Mini SAS HD SFF 8644 4x Mini SAS HD SFF 8644 2x M...

Page 33: ...FC Single port HBA 4 7 00Y3341 A3KX QLogic 16Gb FC Dual port HBA 4 7 00Y3337 A3KW QLogic 16Gb FC Single port HBA 4 7 8 Gb Fibre Channel 46M6050 3591 Brocade 8Gb FC Dual port HBA 4 7 46M6049 3589 Brocade 8Gb FC Single port HBA 4 7 42D0494 3581 Emulex 8Gb FC Dual port HBA 4 7 42D0485 3580 Emulex 8Gb FC Single port HBA 4 7 42D0510 3579 QLogic 8Gb FC Dual port HBA 4 7 42D0501 3578 QLogic 8Gb FC Single...

Page 34: ...ond GPU is installed in slot 6 and requires the second processor to be installed The number of GPUs that can be installed depends on the type of power supply that is installed and the type and number of other components that are installed For more information see the Power Supply section If a NVIDIA card is installed the maximum memory that can be installed is 1 TB Power supplies and redundant coo...

Page 35: ... mutually exclusive RDIMMs No limit No limit No limit No limit No limit No limit No limit No limit No limit 12 No limit LRDIMMs 0 0 0 0 0 12 0 No limit 0 0 No limit Drive maximums mutually exclusive 3 5 inch drives only No limit 6 No limit No limit No limit No limit 6 6 No limit 6 No limit 2 5 inch drives only 16 8 16 16 No limit 24 8 8 No limit 8 No limit Intermix 3 5 in and 2 5 in drives 6x 3 5 ...

Page 36: ...7 2 8M 39Y7922 6214 South Africa 10A line C13 to SABS 164 1 2 8M 39Y7923 6215 United Kingdom 10A line C13 to BS 1363 2 8M 39Y7924 6211 Australia NZ 10A line C13 to SAA AS C112 2 8M 39Y7925 6219 Korea 7A line C13 to KETI 15A 250V 2 8M 39Y7927 6269 India 6A line C13 to Fig 68 2 8M 39Y7928 6210 China 6A line C13 to GB 2099 1 2 8M 39Y7929 6223 Brazil 10A line C13 to NBR 6147 2 8M 39Y7930 6222 Argentin...

Page 37: ...owing table shows the available options The table also indicates whether the option includes the SD Media RAID Adapter and how many SD cards are included Table 33 Virtualization options Part number Feature code Description Includes Adapter SD Cards Included 00ML706 A5TJ SD Media Adapter for Systems x Option 00ML706 includes 2 blank 32GB SD cards Yes 2 00ML700 AS2V Blank 32GB SD Media for System x ...

Page 38: ... required for enabling remote presence and blue screen capture features The remote presence feature provides the following functions Remotely viewing video with graphics resolutions up to 1600x1200 at 75 Hz with up to 23 bits per pixel colors regardless of the system state Remotely accessing the server by using the keyboard and mouse from a remote client Mapping the CD or DVD drive diskette drive ...

Page 39: ...shows the meaning of each LED Figure 13 System LEDs and the optional light path diagnostics panel Note The light path diagnostics panel upgrade kit supplies the array of LEDs that is mounted in a bracket that is installed inside the server as shown in the following figure The light path diagnostics indicators are still visible on the front of the server even if the upgrade kit is not installed Fig...

Page 40: ...EDs FoD per Install w 1Yr S S 1 00FP649 AS6C IBM SKLM for System x w SEDs FoD per Install w 3Yr S S 1 Supported operating systems The server supports the following operating systems Microsoft Windows Server 2008 R2 Microsoft Windows Server 2012 Microsoft Windows Server 2012 R2 SUSE Linux Enterprise Server 11 for AMD64 EM64T SUSE Linux Enterprise Server 11 with Xen for AMD64 EM64T SUSE Linux Enterp...

Page 41: ... 200 240 nominal V ac 50 Hz or 60 Hz 8 35 A Input kilovolt amperes kVA approximately Minimum configuration 0 10 kVA Maximum configuration 1 967 kVA Models with 900 W AC power supplies 100 127 nominal V ac 50 Hz or 60 Hz 10 3 A 200 240 nominal V ac 50 Hz or 60 Hz 5 0 A Input kilovolt amperes kVA approximately Minimum configuration 0 15 kVA Maximum configuration 1 194 kVA Models with 750 W Platinum ...

Page 42: ...to arrive at the client s location within four hours after remote problem determination is completed Lenovo provides service around the clock every day including Lenovo holidays 9x5x4 hour A service technician is scheduled to arrive at the client s location within four business hours after remote problem determination is completed Lenovo provides service 8 00 am 5 00 pm in the client s local time ...

Page 43: ...nt bundles with our warranty upgrades and extensions Microcode Support Keeping microcode current helps prevent hardware failures and security exposure There are two levels of service analysis of the installed base and analysis and update where required Offerings vary by country and can be bundled with other warranty upgrades and extensions Remote Technical Support Services RTS RTS provides compreh...

Page 44: ...BD 64111B2 Lenovo Storage E1012 LFF Disk Expansion Dual SAS IO Module Rail Kit 9x5 NBD 64111B3 Lenovo Storage E1024 SFF Disk Expansion Single SAS IO Module Rail Kit 9x5 NBD 64111B4 Lenovo Storage E1024 SFF Disk Expansion Dual SAS IO Module Rail Kit 9x5 NBD 70F0 70F1 Lenovo ThinkServer SA120 Not available for ordering in North America United States and Canada Machine Type see the Lenovo ThinkServer...

Page 45: ...ge S3200 LFF Chassis FC iSCSI Single Controller Rack Kit 9x5NBD 64116B2 Lenovo Storage S3200 LFF Chassis FC iSCSI Dual Controller Rack Kit 9x5NBD 64113B3 Lenovo Storage S3200 SFF Chassis SAS Single Controller Rack Kit 9x5NBD 64113B4 Lenovo Storage S3200 SFF Chassis SAS Dual Controller Rack Kit 9x5NBD 64116B3 Lenovo Storage S3200 SFF Chassis FC iSCSI Single Controller Rack Kit 9x5NBD 64116B4 Lenovo...

Page 46: ...ckup libraries 61732UL IBM TS3100 Tape Library Model L2U 61734UL IBM TS3200 Tape Library Model L4U Fibre Channel backup drives for TS3100 and TS3200 Tape Libraries 00NA107 6173 LTO Ultrium 5 Fibre Channel Drive 00NA113 6173 LTO Ultrium 5 Half High Fibre Drive Sled 00NA115 6173 LTO Ultrium 6 Fibre Channel Drive 00NA119 6173 LTO Ultrium 6 Half High Fibre Drive Sled 00WF765 6173 LTO Ultrium 7 Fibre C...

Page 47: ...t product guide 10 Gb Ethernet switches http lenovopress com networking tor 10gb rt product guide 40 Gb Ethernet switches http lenovopress com networking tor 40gb rt product guide Fibre Channel SAN switches The following table lists the Fibre Channel SAN switches that are offered by Lenovo and can be used with this system Table 43 Fibre Channel SAN switches Part number Description 8 Gb Fibre Chann...

Page 48: ...8kVA 6U 3 1 Phase Rack or Tower UPS 380 415VAC 55949PX RT11kVA 6U 3 1 Phase Rack or Tower UPS 380 415VAC For more information see the list of Product Guides in the UPS category https lenovopress com servers options ups Power distribution units The following table lists the power distribution units PDUs that are offered by Lenovo Table 45 Power distribution units Part number Description 0U Basic PD...

Page 49: ... 320 C13 outlets 39Y8951 DPI Universal Rack PDU with US LV and HV line cords 39Y8952 DPI Universal Rack PDU with CEE7 VII Europe line cord 39Y8953 DPI Universal Rack PDU with Denmark line cord 39Y8954 DPI Universal Rack PDU with Israel line cord 39Y8955 DPI Universal Rack PDU with Italy line cord 39Y8956 DPI Universal Rack PDU with South Africa line cord 39Y8957 DPI Universal Rack PDU with UK line...

Page 50: ...it included slide kit shown The Tower to Rack Conversion Kit 00AL538 includes a cable management arm however standard rack models for example 5464 C3x and G3x do not include a cable management arm Thefore the arm must be ordered separately by using part number 00KC334 The tower to rack conversion kit supported cable management arm kit rack console switches monitor kits and management gateways are ...

Page 51: ...r GCM16 1754A2X 1754HC4 fc 0726 Local 2x16 Console Manager LCM16 1754A1X 1754HC3 fc 0725 Local 1x8 Console Manager LCM8 Console cables 43V6147 3757 Single Cable USB Conversion Option UCO 39M2895 3756 USB Conversion Option 4 Pack UCO 46M5383 5341 Virtual Media Conversion Option Gen2 VCO2 46M5382 5340 Serial Conversion Option SCO Universal management gateway and cables 3858D3X 3858HC1 fc A4X1 Avocen...

Page 52: ...ack 93604PX 42U 1200mm Deep Dynamic Rack 93614EX 42U 1200mm Deep Static Expansion Rack 93614PX 42U 1200mm Deep Static Rack 93084EX 42U Enterprise Expansion Rack 93084PX 42U Enterprise Rack 93074RX 42U Standard Rack 93074XX 42U Standard Rack Extension 93624EX 47U 1200mm Deep Static Expansion Rack 93624PX 47U 1200mm Deep Static Rack 93634BX PureFlex System 42U Expansion Rack 93634DX PureFlex System ...

Page 53: ...ovide large accounts with special handling services to ensure these complex transactions are serviced properly As a premier client you have a dedicated finance specialist who manages your account through its life from first invoice through asset return or purchase This specialist develops an in depth understanding of your invoice and payment requirements For you this dedication provides a high qua...

Page 54: ...Related product families Product families related to this document are the following 2 Socket Tower Servers Lenovo System x3500 M5 54 ...

Page 55: ...cument are not intended for use in implantation or other life support applications where malfunction may result in injury or death to persons The information contained in this document does not affect or change Lenovo product specifications or warranties Nothing in this document shall operate as an express or implied license or indemnity under the intellectual property rights of Lenovo or third pa...

Page 56: ...rver TopSeller ServerProven System x RackSwitch ServeRAID ToolsCenter TruDDR4 The following terms are trademarks of other companies Intel and Intel Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries Linux is a trademark of Linus Torvalds in the United States other countries or both Microsoft and Windows are trademarks of M...

Reviews: