background image

Lenovo Storage S3200

25

Power distribution units

The following table lists the the power distribution units (PDUs) that are offered by Lenovo that can be 

used in S3200 storage solutions. 

Table 16. Power distribution units (Part 1)

Description

Part number

Switched and Monitored PDUs

1U 9 C19/3 C13 Active Energy Manager DPI PDU

46M4002 

1U 9 C19/3 C13 Active Energy Manager 60A 3 Phase PDU

46M4003 

1U 12 C13 Active Energy Manager DPI PDU

46M4004 

1U 12 C13 Active Energy Manager 60A 3 Phase PDU

46M4005 

1U 9 C19/3 C13 Switched and Monitored 30A 3 Phase PDU

46M4167

0U 24 C13 Switched and Monitored 30A PDU

46M4116

0U 24 C13 Switched and Monitored 32A PDU

46M4119

0U 12 C19/12 C13 Switched and Monitored 50A 3 Phase PDU

46M4134

0U 12 C19/12 C13 Switched and Monitored 32A 3 Phase PDU

46M4137

Enterprise PDUs

Ultra Density Enterprise PDU C19 PDU+ (WW)

71762MX 

Ultra Density Enterprise PDU C19 PDU (WW)

71762NX 

Ultra Density Enterprise PDU C19 3 Phase 60A PDU+ (NA)

71763MU 

Ultra Density Enterprise PDU C19 3 Phase 60A PDU (NA)

71763NU 

DPI C13 Enterprise PDU without linecord

39M2816

DPI 60A Three Phase C19 Enterprise PDU with IEC309 3P+G (208 V) fixed line cord

39Y8923 

DPI Single Phase C13 Enterprise PDU without line cord

39Y8941 

DPI Single Phase C19 Enterprise PDU without line cord

39Y8948 

Front-end PDUs

DPI 32 amp/250 V Front-end PDU with IEC 309 2P+Gnd connector

39Y8934

DPI 63amp/250 V Front-end PDU with IEC 309 2P+Gnd connector

39Y8935

30 amp/125 V Front-end PDU with NEMA L5-30P connector

39Y8938

30 amp/250 V Front-end PDU with NEMA L6-30P connector

39Y8939

60 amp/250 V Front-end PDU with IEC 309 60A 2P+N+Gnd connector

39Y8940

Summary of Contents for S3200

Page 1: ...s the selection of iSCSI or FC host connectivity or both FC and iSCSI as simple as attaching corresponding transceivers or 10 GbE SFP Direct Attach Copper DAC cables to the SFP SFP ports on the RAID controller The S3200 supports up to 192 drives with up to seven external expansion enclosures and it offers flexible drive configurations with the choice of 2 5 inch and 3 5 inch drive form factors 10 ...

Page 2: ...upport for self encrypting drives to allow clients to secure their sensitive data and to comply with various security regulations when required Rich set of standard functions available at no extra cost including virtualized storage pools snapshots thin provisioning rapid rebuild real time HDD tiering and SSD read cache Optional licensed functions including higher number of snapshots for added scal...

Page 3: ...se the level of data protection that is required Virtualized storage pools Enables rapid flexible storage provisioning and simple configuration changes Stored data is distributed across all drive groups in the pool wide striping which helps improve performance lower latency and achieve higher volume capacities When a new drive group is added to the pool the system performs automatic rebalancing to...

Page 4: ...ata to SSDs in the system which results in flash drive performance without manually creating and managing storage tier policies Snapshots upgrade The snapshot upgrade options increase the supported number of snapshot targets to 512 or 1 024 per system The S3200 supports the following management interfaces Web based graphical user interface GUI via HTTP that requires only a supported browser Micros...

Page 5: ...FF chassis and E1024 drive expansion enclosure Figure 2 Front view of the S3200 SFF chassis and E1024 drive enclosure The following figure shows the front of the S3200 LFF chassis and E1012 drive expansion enclosure Figure 3 Front view of the S3200 LFF chassis and E1012 drive enclosure ...

Page 6: ...ingle RAID controller configurations also are supported Figure 4 Rear view of the S3200 with FC or iSCSI host interfaces The following figure shows the rear of the S3200 with SAS host interfaces with dual RAID controllers Single RAID controller configurations also are supported Figure 5 Rear view of the S3200 with SAS host interfaces ...

Page 7: ... controllers S3200 SAS controller S3200 FC and iSCSI controller Single or dual RAID controller configurations supported Single controller systems can be upgraded to dual controller non disruptively Both controllers in the system must be the same RAID levels RAID 0 1 5 6 and 10 RAID controller cache 6 GB per controller Battery free cache protection with flash memory and supercapacitors Low latency ...

Page 8: ... CNCs might have different connectivity types CNC host port options per each CNC on the RAID controller 2x 1 Gb iSCSI SFP 1 Gb speed UTP RJ 45 2x 10 Gb iSCSI SFP 1 10 Gb speeds SW fiber optics LC 2x 8 Gb FC SFP 4 8 Gb speeds SW fiber optics LC 2x 16 Gb FC SFP 4 8 16 Gb speeds SW fiber optics LC 2x 10 Gb iSCSI SFP DAC cables Host operating systems Microsoft Windows Server 2012 and 2012 R2 Red Hat E...

Page 9: ...7 6 in depth 519 mm 20 5 in Weight S3200 LFF Minimum 18 4 kg 40 6 lb Maximum 28 2 kg 62 2 lb S3200 SFF Minimum 18 5 kg 40 8 lb Maximum 25 0 kg 55 2 lb E1012 Minimum 16 8 kg 37 0 lb Maximum 26 6 kg 58 6 lb E1024 Minimum 16 9 kg 37 2 lb Maximum 23 4 kg 51 6 lb Controller enclosures The following table lists the models of the S3200 chassis Table 2 Part numbers and feature codes for ordering S3200 mod...

Page 10: ...r SFP SFP ports per RAID controller Ports on the CNC must have the same connectivity type and different CNCs might have different connectivity types The Converged Network Controller supports the following storage connectivity protocols depending on the SFP SFP transceivers that are installed 1 Gb iSCSI with 1 GbE RJ 45 SFP optical modules 1 10 Gb iSCSI with 10 GbE SW SFP optical modules with LC co...

Page 11: ...00MN517 ASRB 8 DAC cable options for 10 Gb iSCSI host connectivity Lenovo 1m Passive SFP DAC Cable 90Y9427 A1PH 8 Lenovo 2m Passive SFP DAC Cable 00AY765 A51P 8 Lenovo 3m Passive SFP DAC Cable 90Y9430 A1PJ 8 SAS host connectivity cables Mini SAS HD controller to Mini SAS host 1 5m HD miniSAS to miniSAS SAS Cable 00D5224 A3HX 8 3m HD miniSAS to miniSAS SAS Cable 00D5226 A3HY 8 SAS host connectivity...

Page 12: ...n modules installed Two 4 3 m 10 A 100 250 V C13 to IEC 320 C14 Rack Power Cables Lenovo Storage SAN Rack Mount Kit Rails 25 inch to 36 inch Getting Started Guide Warranty Flyer Important Notices Flyer Documentation CD ROM The E1012 and E1024 support single and dual expansion module configurations Standard models of the E1012 and E1024 ship with two expansion modules for more information see Table...

Page 13: ...0 13 The expansion connectivity topology for dual controller configurations is shown in the following figure For single controller configurations only Controller A path is present Figure 7 Expansion connectivity topology ...

Page 14: ...to 12 LFF hot swap drives The S3200 SFF chassis and the E1024 expansion enclosure support up to 24 SFF hot swap drives The following table lists drive options for the S3200 LFF chassis and the E1012 expansion enclosure Table 6 LFF drive options Description Part number Feature code MTM 6411 HC2 6411 HC3 Maximum qty per one S3200 LFF or E1012 3 5 inch SAS hot swap HDDs Lenovo Storage 3 5 600GB 10K S...

Page 15: ...SED 00WC020 AT1L 24 Lenovo Storage 2 5 900GB 10k SAS HDD SED 00MM745 AT1N 24 Lenovo Storage 2 5 1 2TB 10k SAS HDD SED 00MM740 AT1Q 24 2 5 inch NL SAS hot swap HDDs Lenovo Storage 2 5 1TB 7 2k NL SAS HDD 00MM705 AT1R 24 2 5 inch SAS hot swap SSDs Lenovo Storage 2 5 400GB SSD SAS 00MM720 AT1S 24 Lenovo Storage 2 5 800GB SSD SAS 00MM715 AT1T 24 Lenovo Storage 2 5 1 6TB SSD SAS 00MM710 AT1U 24 Softwar...

Page 16: ...ordering power cables Part 1 Description Part number Feature code MTM 6411 HC2 6411 HC3 Rack power cables 1 2m 10A 100 250V 2 Short C13s to Short C14 Rack Power Cable 47C2487 A3SS 1 2m 16A 100 250V 2 Short C13s to Short C20 Rack Power Cable 47C2491 A3SW 1 5m 10A 100 250V C13 to IEC 320 C14 Rack Power Cable 39Y7937 6201 2 5m 10A 100 250V 2 Long C13s to Short C14 Rack Power Cable 47C2488 A3ST 2 5m 1...

Page 17: ...38 2 8m line cord 39Y7927 6269 Israel 10A 250V C13 to SI 32 2 8m line cord 39Y7920 6218 Italy 10A 250V C13 to CEI 23 16 2 8m line cord 39Y7921 6217 Japan 10A 100V C13 to JIS C 8303 2 8m line cord 46M2593 A1RE Korea 12A 250V C13 to KETI 2 8m line cord 39Y7925 6219 South Africa 10A 250V C13 to SABS 164 2 8m line cord 39Y7922 6214 Switzerland 10A 250V C13 to SEV 1011 S24507 2 8m line cord 39Y7919 621...

Page 18: ...ient s location within four business hours after remote problem determination is completed Lenovo provides service 8 00 am 5 00 pm in the client s local time zone Monday Friday excluding Lenovo holidays For example if a customer reports an incident at 3 00 pm on Friday the technician will arrive by 10 00 am the following Monday 9x5 next business day A service technician is scheduled to arrive at t...

Page 19: ...ides end to end storage compatibility testing to deliver interoperability throughout the network The S3200 supports attachment to Lenovo System x ThinkServer and Flex System hosts by using SAS iSCSI FC or FC over Ethernet FCoE via the FCoE gateway storage connectivity protocols Hybrid storage connectivity also is supported SAS interoperability The System x and ThinkServer SAS adapters that are lis...

Page 20: ...pport page on the Lenovo support web site http support lenovo com or ask a Lenovo representative Fibre Channel interoperability The S3200 supports direct FC attachments and FC switch based attachments Brocade and QLogic SAN switches can be used to provide FC connectivity with the S3200 FC storage The System x ThinkServer and Flex System FC adapters that are listed in the following table are compat...

Page 21: ...0F28650 ThinkServer LPe16002B M6 L PCIe 16Gb 2 Port FC HBA by Emulex 4XB0F28705 ThinkServer LPe16004B M6 L PCIe 16Gb 4 Port FC HBA by Emulex 4XB0F28681 ThinkServer LPm16002 M6 L AnyFabric 16Gb 2 Port FC HBA by Emulex 4XB0F28706 ThinkServer servers 8 Gb FC ThinkServer QLE2562 Dual Port 8Gb Fibre Channel HBA by Qlogic 0C19482 ThinkServer LPe16002B M8 L PCIe 8Gb 2 Port FC HBA by Emulex 4XB0F28704 Thi...

Page 22: ...witches The following table lists the Ethernet and Fibre Channel rack mount switches that are offered by Lenovo that can be used in S3200 storage solutions Table 13 Ethernet and Fibre Channel rack mount switches Description Part number 1 Gb Ethernet Lenovo RackSwitch G7028 Rear to Front 7159BAX Lenovo RackSwitch G7052 Rear to Front 7159CAX Lenovo RackSwitch G8052 Rear to Front 7159G52 10 Gb Ethern...

Page 23: ... 94Y5350 Cisco Nexus B22 Fabric Extender with FET bundle for Flex System 94Y5355 Converged 10 GbE and 8 Gb FC FCoE gateways Lenovo Flex System Fabric CN4093 10Gb Converged Scalable Switch 00FM510 Converged 10 GbE and 16 Gb FC FCoE gateways Flex System EN4023 10Gb Scalable Switch 94Y5212 16 Gb Fibre Channel Flex System FC5022 16 Gb SAN Scalable Switch 88Y6374 Flex System FC5022 24 port 16 Gb SAN Sc...

Page 24: ...eep Dynamic Rack 93604PX 42U 1200mm Deep Static Expansion Rack 93614EX 42U 1200mm Deep Static Rack 93614PX 42U Enterprise Expansion Rack 93084EX 42U Enterprise Rack 93084PX 42U Standard Rack 93074RX 42U Standard Rack Extension 93074XX 47U 1200mm Deep Static Expansion Rack 93624EX 47U 1200mm Deep Static Rack 93624PX PureFlex System 42U Expansion Rack 93634BX PureFlex System 42U Expansion Rack 93634...

Page 25: ...U 46M4134 0U 12 C19 12 C13 Switched and Monitored 32A 3 Phase PDU 46M4137 Enterprise PDUs Ultra Density Enterprise PDU C19 PDU WW 71762MX Ultra Density Enterprise PDU C19 PDU WW 71762NX Ultra Density Enterprise PDU C19 3 Phase 60A PDU NA 71763MU Ultra Density Enterprise PDU C19 3 Phase 60A PDU NA 71763NU DPI C13 Enterprise PDU without linecord 39M2816 DPI 60A Three Phase C19 Enterprise PDU with IE...

Page 26: ...niversal Rack PDU with UK LC 39Y8957 DPI Universal Rack PDU with AS NZ LC 39Y8958 DPI Universal Rack PDU with China LC 39Y8959 DPI Universal Rack PDU Argentina 39Y8962 DPI Universal Rack PDU Brazil 39Y8960 DPI Universal Rack PDU India 39Y8961 0U Basic PDUs 0U 24 C13 16A 3 Phase PDU 46M4122 0U 24 C13 30A 3 Phase PDU 46M4125 0U 24 C13 30A PDU 46M4128 0U 24 C13 32A PDU 46M4131 0U 12 C19 12 C13 60A 3 ...

Page 27: ...42AX RT2 2kVA 2U Rack or Tower UPS 200 240VAC 55942KX RT3kVA 2U Rack or Tower UPS 100 125VAC 55943AX RT3kVA 2U Rack or Tower UPS 200 240VAC 55943KX RT5kVA 3U Rack or Tower UPS 200 240VAC 55945KX RT6kVA 3U Rack or Tower UPS 200 240VAC 55946KX RT8kVA 6U Rack or Tower UPS 200 240VAC 55948KX RT11kVA 6U Rack or Tower UPS 200 240VAC 55949KX RT8kVA 6U 3 1 Phase Rack or Tower UPS 380 415VAC 55948PX RT11kV...

Page 28: ...allow you to bundle everything you need from hardware and software to service contracts installation costs training fees and sales tax If you decide weeks or months later to add to your solution we can consolidate everything into a single invoice Our Premier Client services provide large accounts with special handling services to ensure these complex transactions are serviced properly As a premier...

Page 29: ...publication Lenovo may make improvements and or changes in the product s and or the program s described in this publication at any time without notice The products described in this document are not intended for use in implantation or other life support applications where malfunction may result in injury or death to persons The information contained in this document does not affect or change Lenov...

Page 30: ...indicating US registered or common law trademarks owned by Lenovo at the time this information was published Such trademarks may also be registered or common law trademarks in other countries A current list of Lenovo trademarks is available on the Web at http www lenovo com legal copytrade html The following terms are trademarks of Lenovo in the United States other countries or both Flex System Le...

Reviews: