Lenovo Flex System SI4091 10Gb Product Manual Download Page 2

Key features

The SI4091 interconnect module is considered particularly suited for the following customers:

Customers who want simple 10 GbE network connectivity from the chassis to the upstream network,

without the complexity of spanning tree and other advanced Layer 2 and Layer 3 features.
Customers who want to manage physical compute node connectivity in the chassis by using the existing

network management tools.
Customers who want to reduce total cost of ownership (TCO) and improve performance, while

maintaining high levels of availability and security.
Customers who want to minimize oversubscription, which can result in congestion and loss of

performance.
Customers who want to implement a converged infrastructure with NAS, iSCSI, or FCoE. For FCoE

implementations, the SI4091 passes through FCoE traffic upstream to other devices (such as the

Lenovo RackSwitch™ G8264CS) where the FC traffic is broken out.

The SI4091 offers the following key features and benefits:

Increased performance

With the growth of virtualization and the evolution of cloud computing, many of today’s applications

require low latency and high-bandwidth performance. The SI4091 supports sub-microsecond latency

and up to 480 Gbps throughput, while delivering full line rate performance.

The SI4091 also offers increased security and performance advantage when configured in VLAN-aware

mode; it does not force communications upstream into the network, which reduces latency and

generates less network traffic.

Simplified network infrastructure

The SI4091 simplifies the deployment of a converged LAN and SAN with support for the newest

protocols, including Data Center Bridging/Converged Enhanced Ethernet (DCB/CEE), which can be used

in a converged iSCSI, Fibre Channel over Ethernet (FCoE) or NAS environment.

The default configuration of the SI4091 requires little or no management for most data center

environments, which eliminates the need to configure each device or individual ports and reduces the

number of management points.

Transparent networking The SI4091 is a transparent network device that is invisible to the upstream

network and eliminates network administration concerns of Spanning Tree Protocol configuration and

interoperability, VLAN assignments, and avoidance of possible loops.

By emulating a host NIC to the data center core, it accelerates the provisioning of virtual machines (VMs)

by eliminating the need to configure the typical access switch parameters.

Components and connectors

Lenovo Flex System SI4091 10Gb System Interconnect Module

2

Summary of Contents for Flex System SI4091 10Gb

Page 1: ...em Fabric SI4091 System Interconnect Module is shown in the following figure Figure 1 Lenovo Flex System Fabric SI4091 System Interconnect Module Did you know The SI4091 provides transparent Flex System connectivity to your Cisco Juniper or other vendor network The SI4091 aggregates compute node ports by appearing as a simple pass thru device The upstream network sees a large pipe of server traffi...

Page 2: ... microsecond latency and up to 480 Gbps throughput while delivering full line rate performance The SI4091 also offers increased security and performance advantage when configured in VLAN aware mode it does not force communications upstream into the network which reduces latency and generates less network traffic Simplified network infrastructure The SI4091 simplifies the deployment of a converged ...

Page 3: ...pecifications Component Specification Form factor Flex System embedded I O module Ports Internal ports 14x 10 Gb Ethernet ports External ports 10x SFP SFP ports Media types external ports 10 Gb Ethernet SFP 10 GbE short range SR SFP transceivers 10 GbE long range LR SFP transceivers 10 GbE extended range ER SFP transceivers 10 GbE RJ 45 SFP transceivers 10 GbE SFP active optical cables AOCs 10 GbE...

Page 4: ...aceable unit limited warranty When installed in a supported chassis the module assumes the chassis base warranty and any warranty service upgrade warranty includes Networking OS software upgrades Mean Time Between Failures 261 636 hours with ambient operating temperature of 40 C Dimensions Height 30 mm 1 2 in width 401 mm 15 8 in depth 317 mm 12 5 in Weight 3 7 kg 8 1 lb Component Specification Mo...

Page 5: ...ters on single mode fiber The supported transceivers and cables are listed in the following table Table 3 Supported transceivers and DAC cables Description Part number Feature code Maximum quantity supported Serial console cables Flex System Management Serial Access Cable Kit 90Y9338 A2RR 1 SFP transceivers 1 GbE Lenovo 1000BASE T RJ 45 SFP Transceiver no 10 100 Mbps support 00FE333 A5DL 10 Lenovo...

Page 6: ...o 400 m with OM4 multimode fiber LC 10Gb LR SFP 90Y9412 10GBASE LR 1310 nm single mode fiber cable up to 10 km LC 10Gb ER SFP 90Y9415 10GBASE ER 1310 nm single mode fiber cable up to 40 km LC 10Gb RJ 45 SFP 7G17A03130 10GBASE T UTP Category 6a or 7 up to 30 meters RJ 45 Active optical cable 10GBASE SR SFP active optical cables up to 20 m see Table 3 SFP Direct attach copper cable 10GSFP Cu SFP DAC...

Page 7: ...02 3ad link aggregation Availability and redundancy Layer 2 Trunk Failover to support active standby configurations of NIC teaming on compute nodes Hot Links provide basic link redundancy and fast recovery for network topologies without a need for Spanning Tree protocol VLAN support Up to 4 095 VLANs supported with VLAN numbers 1 4095 4095 is used for management network 802 1Q VLAN tagging support...

Page 8: ...IEEE 802 3ad Link Aggregation Control Protocol IEEE 802 3ae 10GBASE SR short range fiber optics 10 Gb Ethernet IEEE 802 3ae 10GBASE LR long range fiber optics 10 Gb Ethernet IEEE 802 3ae 10GBASE ER extended range fiber optics 10 Gb Ethernet IEEE 802 3ap 10GBASE KR backplane 10 Gb Ethernet IEEE 802 3u 100BASE TX Fast Ethernet IEEE 802 3x Full duplex Flow Control IEEE 802 3z 1000BASE SX short range ...

Page 9: ...x System Chassis The SI4091 interconnect modules can be installed in bays 1 2 3 and 4 of the Flex System chassis A supported adapter must be installed in the corresponding slot of the compute node Although an adapter can use up to four ports to connect to the respective I O module bay the SI4091 can use only one of the four ports In compute nodes that have an integrated dual port 10 GbE network in...

Page 10: ...e nodes support up to four adapters Table 6 Adapter to I O bay correspondence I O adapter slot in the compute node Port on the adapter Corresponding I O bay in the chassis Bay 1 Bay 2 Bay 3 Bay 4 Slot 1 Port 1 Yes Port 2 Yes Slot 2 Port 1 Yes Port 2 Yes Slot 3 full wide compute nodes only Port 1 Yes Port 2 Yes Slot 4 full wide compute nodes only Port 1 Yes Port 2 Yes Lenovo Flex System SI4091 10Gb...

Page 11: ...dapter 00AG540 ATBT Flex System CN4052S 2 port 10Gb Virtual Fabric Adapter Advanced 01CV780 AU7X Flex System CN4054 10Gb Virtual Fabric Adapter 4 port 90Y3554 A1R1 Flex System CN4054R 10Gb Virtual Fabric Adapter 4 port 00Y3306 A4K2 Flex System CN4054S 4 port 10Gb Virtual Fabric Adapter 00AG590 ATBS Flex System CN4054S 4 port 10Gb Virtual Fabric Adapter Advanced 01CV790 AU7Y Flex System EN4132 2 po...

Page 12: ...hen the SI4091 is used with the Lenovo RackSwitch switches Virtual Link Aggregation Groups vLAGs can be used for load balancing and redundancy purposes The virtual link aggregation topology with the Lenovo RackSwitch G8272 is shown in the following figure Figure 5 SI4091 connectivity topology Virtual Link Aggregation In this loop free topology aggregation is split between two physical switches whi...

Page 13: ...stems Description Part number Lenovo Storage DX8200 Series NAS iSCSI connectivity Lenovo Storage DX8200D ServerSAN Entry 8TB 3yr SW S S 5135D2x Lenovo Storage DX8200D ServerSAN Entry 8TB 4yr SW S S 5135N2x Lenovo Storage DX8200D ServerSAN Entry 8TB 5yr SW S S 51354Vx Lenovo Storage DX8200D ServerSAN Mid 16TB 3yr SW S S 5135F2x Lenovo Storage DX8200D ServerSAN Mid 16TB 4yr SW S S 5135P2x Lenovo Sto...

Page 14: ...l Enclosure 5Yr S S 6536C32 Lenovo Storage V5030 SFF Control Enclosure 3Yr S S 6536C22 Lenovo Storage V5030 SFF Control Enclosure 5Yr S S 6536C42 Lenovo Storage V5030F SFF Control Enclosure 3Yr S S 6536B1F Lenovo Storage V5030F SFF Control Enclosure 5Yr S S 6536B2F IBM Storwize for Lenovo iSCSI connectivity end to end FCoE connectivity FCoE FC gateway connectivity IBM Storwize V3500 3 5 inch Dual ...

Page 15: ...see the following Lenovo Flex System Fabric SI4091 System Interconnect Module product publications which are available from the Flex System Information Center http flexsystem lenovofiles com help topic com lenovo acc si4091pt doc IO_Module_SI4091 html Flex System SI4091 10Gb System Interconnect Module Installation Guide Flex System SI4091 10Gb System Interconnect Module Application Guide Flex Syst...

Page 16: ...ntended for use in implantation or other life support applications where malfunction may result in injury or death to persons The information contained in this document does not affect or change Lenovo product specifications or warranties Nothing in this document shall operate as an express or implied license or indemnity under the intellectual property rights of Lenovo or third parties All inform...

Page 17: ...o trademarks is available on the Web at http www3 lenovo com us en legal copytrade The following terms are trademarks of Lenovo in the United States other countries or both Flex System Lenovo XClarity Lenovo RackSwitch ThinkSystem Other company product or service names may be trademarks or service marks of others Lenovo Flex System SI4091 10Gb System Interconnect Module 17 ...

Reviews: