background image

46     

CE0128TB/CE0128PB/CE0152TB/CE0152PB Installation Guide

Summary of Contents for Campus Series

Page 1: ...Lenovo CE0128TB CE0128PB CE0152TB CE0152PB Campus series Ethernet Switch Installation Guide ...

Page 2: ...es document included with the product First Edition March 2019 Copyright Lenovo 2019 LIMITED AND RESTRICTED RIGHTS NOTICE If data or software is delivered pursuant a General Services Administration GSA contract use reproduction or disclosure is subject to restrictions set forth in Contract No GS 35F 05925 Lenovo and the Lenovo logo are trademarks of Lenovo in the United States other countries or b...

Page 3: ... Panel Components 15 LED Indicators 16 Back Panel Components 18 Side Panel Components 19 Hardware Installation 21 Installation into a Rack 22 Installing Transceivers into the Transceiver Ports 24 Technical Specifications 25 Physical Characteristics 25 Environmental Specifications 26 Cooling Specifications 26 Power Specifications 27 Power over Ethernet Specifications 28 Port Specifications 29 Getti...

Page 4: ...s A Statement 41 European Union Compliance to the Electromagnetic Compatibility Directive 42 Germany Class A Statement 42 Japan VCCI Class A Statement 43 Japan Electronics and Information Technology Industries Association JEITA Statement 44 Korea Communications Commission KCC Statement 44 Russia Electromagnetic Interference EMI Class A statement 44 People s Republic of China Class A electronic emi...

Page 5: ... Lees voordat u dit product installeert eerst de veiligheidsvoorschriften Ennen kuin asennat tämän tuotteen lue turvaohjeet kohdasta Safety Information Avant d installer ce produit lisez les consignes de sécurité Vor der Installation dieses Produkts die Sicherheitshinweise lesen Πριν εγκαταστήσετε το προϊόν αυτό διαβάστε τις Πληροφορίες ασφαλείας safety information A termék telepítés előtt olvassa...

Page 6: ...es sobre Segurança Перед установкой продукта прочтитe инcтрyкции по тexникe безопасности Pred inštaláciou tohto zariadenia si prečítajte Bezpečnostné predpisy Pred namestitvijo tega proizvoda preberite Varnostne informacije Antes de instalar este producto lea la información de seguridad Läs säkerhetsinformationen innan du installerar den här produkten Bu ürünü kurmadan önce güvenlik bilgilerini ok...

Page 7: ...de may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause interference In this case the user is required to correct the interference at their own expense Warning Changes or modifications made to this device that are not expressly approved by the party responsible for compliance could void the user s authority to operate the equip...

Page 8: ... est sous tension Ne regardez jamais directement le port TX Tramsmission à fibres optiques et les embouts de câbles à fibres optiques tant qu ils sont sous tension SFP and SFP Regulatory Compliance Class 1 EN60825 1 2007 2nd Edition or later European standard FCC 21 CFR Chapter 1 Subchapter J in accordance with FDA and CDRH requirements Application of CE Mark in accordance with 2004 108 EEC EMC Di...

Page 9: ...lt die Anforderungen an die Schutzerdung nach NEC National Electrical Code UL CSA IEC EN 60950 1 Acoustique information sur le bruit Ordonnance tiers GPSGV le niveau de pression acoustique le plus élevé est de 63 5 dB A ou moins L installation du système tel que décrit dans ce guide est conforme aux exigences de mise à la terre de protection des normes NEC Code national de l électricité UL CSA IEC...

Page 10: ...cal lens Do not install in direct sunlight or a damp or dusty place Do not expose the device to moisture or water Disconnect all power supply cords before servicing Electrical Safety Precautions For your protection observe the following electrical safety precautions when setting up your equipment Ensure that the voltage and frequency of your power source match the voltage and frequency inscribed o...

Page 11: ...in an environment compatible with the maximum ambient temperature Tma specified by the manufacturer Reduced Air Flow Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised Mechanical Loading Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechani...

Page 12: ...12 CE0128TB CE0128PB CE0152TB CE0152PB Installation Guide ...

Page 13: ...ient Ethernet EEE standard to save power while links are online or to automatically notify selective ports to enter standby mode when no traffic is transmitted or received Package Contents After purchasing any of the switches in the series the following items are included in the package One CE0128TB CE0128PB CE0152TB CE0152PB Series Switch One Open Source Information EULA document One Regulatory C...

Page 14: ...14 CE0128TB CE0128PB CE0152TB CE0152PB Installation Guide ...

Page 15: ...e front panels of the switches in the series Table 1 Switch Ports Port Description Management Port MGMT One Out Of Band OOB RJ45 management port Console Port One RJ45 port for serial console access RJ45 Ethernet Ports CE0128TB 24 Gigabit RJ45 ports operating at 10 100 1000 Mbps CE0128PB 24 Gigabit RJ45 Power over Ethernet PoE ports operating at 10 100 1000 Mbps CE0152TB 48 Gigabit RJ45 ports opera...

Page 16: ...n Solid light Stacking Master or Standalone Off Stacking Member Fan Green Solid light Diagnostics passed and normal operation Off No power Amber Solid light Fan failure Off No power Power Green Solid light Power on and normal operation Off Power off or no power cable attached Management Port two LEDs left LED Link right LED Speed Green Solid light Right LED Connection link up Left LED 100 Mbps con...

Page 17: ...e connection or port disabled Amber Solid light Connection active at 10 100 1000 Mbps with PoE being supplied Blinking Data transmitting and receiving with PoE being supplied Slow blinking PoE supplied but no Ethernet link or port disabled Off No active connection or port disabled Green Amber Alternating PoE power fault Link Activity Speed SFP Ports Green Solid light Connection active at 10 Gbps B...

Page 18: ...tches in the series AC Power Receptacle 100 240 V 0 5 A Max 50 60 HZ Grounding Point AC Power Receptacle 100 240 V 2 7 A Max 50 60 HZ Grounding Point AC Power Receptacle 100 240 V 0 9 A Max 50 60 HZ Grounding Point AC Power Receptacle 100 240 V 5 5 A Max 50 60 HZ Grounding Point Table 3 Back Panel Components Component Description Grounding Point One electrical grounding screw AC Power Receptacle O...

Page 19: ...eries feature the following components Figure 8 CE0128TB Side Panels Figure 9 CE0128PB Side Panels Figure 10 CE0152TB and CE0152PB Side Panels Fans Rack mount Bracket Holes Rack mount Bracket Holes Fans Rack mount Bracket Holes Rack mount Bracket Holes Fans Rack mount Bracket Holes Rack mount Bracket Holes ...

Page 20: ...under 35 C the fans function at low speed If the ambient temperature is above 40 C the fans function at high speed Note For more information about rack mount installation see Installation into a Rack on page 22 Table 4 Side Panel Components Component Description Fans CE0128TB Two ventilation fans on the right side panel CE0128PB Three ventilation fans on the right side panel CE0152TB Two ventilati...

Page 21: ...afely install the switch into the appropriate environment Notes Read the Safety Information on page 5 before starting any installation discussed in this chapter If the switch is a replacement switch copy the product information from the original switch onto the RID label that is shipped with replacement switch and affix the new label to the bottom of the new switch ...

Page 22: ...ends on the rack mount unit screws being used Four rack mount unit screws These screws are used to attach the switch onto to the rack mount unit and are not included in the switch s packaging as rack mount units differ at each installation site Four rack mount unit cage nuts These cage nuts are used to attach the switch onto to the rack mount unit and are not included in the switch s packaging as ...

Page 23: ...nuts and the additional screwdriver to fasten the frontal rack mount brackets onto the front of the rack mount unit Note Make sure that there is adequate space around the switch to allow for proper airflow ventilation and cooling As a precaution install the switch in a fairly cool and dry place within the acceptable temperature and humidity operating ranges ...

Page 24: ...es This switch supports both fiber and copper cabling solutions For low cost cabling copper based 10 Gbps Twinaxial cables can be used and for longer cable reaches Short Reach SR optical transceivers are excellent Connectivity can be established from the SFP ports to 10 Gbps Ethernet switches or hosts using a fiber or copper cable that has SFP transceivers installed on both ends The figure below i...

Page 25: ...ysical Characteristics Dimension H x W x D 4 4 x 44 x 25 4 cm 1 73 x 17 3 x 10 in Weight 3 21 kg 7 lbs Table 6 CE0128PB Physical Specifications Specification Physical Characteristics Dimension H x W x D 4 4 x 44 x 25 4 cm 1 73 x 17 3 x 10 in Weight 3 69 kg 8 1 lbs Table 7 CE0152TB Physical Specifications Specification Physical Characteristics Dimension H x W x D 4 4 x 44 x 25 4 cm 1 73 x 17 3 x 10...

Page 26: ...nvironmental Specifications Specification Measurement Temperature operating 0 C to 50 C 32 F to 122 F Temperature storage 20 C to 70 C 4 F to 158 F Humidity non condensing operating 5 to 95 Humidity non condensing storage 0 to 95 Altitude 0 to 3000 m 0 to 9843 ft Table 10 CE0128TB and CE0152TB Cooling Specifications Specification Description Number of Fans 2 Fan Speed Automatic high and low speed ...

Page 27: ...e 13 CE0128PB Power Specifications Specification Measurement AC Input Voltage 100 240 VAC AC Input Frequency 50 60 Hz AC Power Supply Efficiency 85 to 88 Power Consumption Maximum 235 W from 260 W PSU Table 14 CE0152TB Power Specifications Specification Measurement AC Input Voltage 100 240 VAC AC Input Frequency 50 60 Hz AC Power Supply Efficiency 85 to 88 Power Consumption Maximum 50 W from 60 W ...

Page 28: ...802 3at PoE Yes Supplies 30 W per port Automatic PD Discovery Yes Supplies power immediately if PD device was detected PoE Safety Automatically disable individual ports when electrical current is over 600 mA or when electrical short occurred Table 17 CE0152PB PoE Specifications Specification Measurement PoE Budget Maximum 370 W for 460 W PSU IEEE 802 3af PoE Yes Supplies 15 4 W per port IEEE 802 3...

Page 29: ...ts 1 10 Gbps Table 19 CE0128PB Port Specifications Specification Measurement Form Factor 1U Fixed Form Factor Physical Ports 24 RJ45 Ethernet Ports 10 100 1000 Mbps with PoE 4 SFP Ports 1 10 Gbps Table 20 CE0152TB Port Specifications Specification Measurement Form Factor 1U Fixed Form Factor Physical Ports 48 RJ45 Ethernet Ports 10 100 1000 Mbps 4 SFP Ports 1 10 Gbps Table 21 CE0152PB Port Specifi...

Page 30: ...30 CE0128TB CE0128PB CE0152TB CE0152PB Installation Guide ...

Page 31: ...ntenance contract Your service technician will request that you upgrade your software and firmware if the problem has a documented solution within a software upgrade If you have installed new hardware or software in your environment check the Lenovo Support portal to make sure that the hardware and software is supported by your product and where you can check for information to help you solve the ...

Page 32: ...nostic tests that you can perform The documentation for most systems operating systems and programs contains troubleshooting procedures and explanations of error messages and error codes If you suspect a software problem see the documentation for the operating system or program ...

Page 33: ...implied warranties in certain transactions therefore this statement may not apply to you This information could include technical inaccuracies or typographical errors Changes are periodically made to the information herein these changes will be incorporated in new editions of the publication Lenovo may make improvements and or changes in the product s and or the program s described in this publica...

Page 34: ... environments may vary significantly Some measurements may have been made on development level systems and there is no guarantee that these measurements will be the same on generally available systems Furthermore some measurements may have been estimated through extrapolation Actual results may vary Users of this document should verify the applicable data for their specific environment ...

Page 35: ...ted States other countries or both Intel and Intel Xeon are trademarks of Intel Corporation in the United States other countries or both Internet Explorer Microsoft and Windows are trademarks of the Microsoft group of companies Linux is a registered trademark of Linus Torvalds Other company product or service names may be trademarks or service marks of others ...

Page 36: ...e bays with the largest currently supported drives that are available from Lenovo Maximum memory might require replacement of the standard memory with an optional memory module Each solid state memory cell has an intrinsic finite number of write cycles that the cell can incur Therefore a solid state device has a maximum number of write cycles that it can be subjected to expressed as total bytes wr...

Page 37: ...tch You may send your request in writing to the address below accompanied by a check or money order for 5 to Lenovo Legal Department 8001 Development Dr Morrisville NC 27560 U S A Attention Open Source Team Source Code Requests Please include both a NOS Release version and model number or Machine Type MT of your Lenovo Switch as part of your request Be sure to provide a return address The open sou...

Page 38: ...wners of information technology IT equipment to responsibly recycle their equipment when it is no longer needed Lenovo offers a variety of programs and services to assist equipment owners in recycling their IT products For information on recycling Lenovo products go to https www lenovo com recycling ...

Page 39: ...vo may condition provision of repair or replacement of devices or parts on implementation of appropriate remedial measures to mitigate such environmental contamination Implementation of such remedial measures is a customer responsibility Contaminant Limits Particulate The room air must be continuously filtered with 40 atmospheric dust spot efficiency MERV 9 according to ASHRAE Standard 52 21 Air t...

Page 40: ...atement This product may not be certified in your country for connection by any means whatsoever to interfaces of public telecommunications networks Further certification may be required by law prior to making any such connection Contact a Lenovo representative or reseller for any questions ...

Page 41: ...expense Properly shielded and grounded cables and connectors must be used to meet FCC emission limits Lenovo is not responsible for any radio or television interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications to this equipment Unauthorized changes or modifications could void the user s authority to operate the equipment This device c...

Page 42: ...interference in which case the user may be required to take adequate measures Germany Class A Statement Deutschsprachiger EU Hinweis Hinweis für Geräte der Klasse A EU Richtlinie zur Elektromagnetischen Verträglichkeit Dieses Produkt entspricht den Schutzanforderungen der EU Richtlinie 2014 30 EU früher 2004 108 EC zur Angleichung der Rechtsvorschriften über die elektromagnetische Verträglichkeit ...

Page 43: ... diesem Fall kann vom Betreiber verlangt werden angemessene Maßnahmen durchzuführen und dafür aufzukommen Nach dem EMVG Geräte dürfen an Orten für die sie nicht ausreichend entstört sind nur mit besonderer Genehmigung des Bundesministers für Post und Telekommunikation oder des Bundesamtes für Post und Telekommunikation betrieben werden Die Genehmigung wird erteilt wenn keine elektromagnetischen St...

Page 44: ...ics and Information Technology Industries Association JEITA Confirmed Harmonics Guidelines with Modifications products greater than 20 A per phase Korea Communications Commission KCC Statement This is electromagnetic wave compatibility equipment for business Type A Sellers and users need to pay attention to it This is for any areas other than home Russia Electromagnetic Interference EMI Class A st...

Page 45: ...minated diphenyl ethers PBDE 外殼 印刷電路板 電源供應器 線材 備考 1 超出 0 1 wt 及 超出 0 01 wt 係指限用物質之百分比含量超出百分比含量基 準值 Note 1 Exceeding 0 1 wt and exceeding 0 01 wt indicate that the percentage content of the restricted sub stance exceeds the reference percentage value of presence condition 備考 2 係指該項限用物質之百分比含量未超出百分比含量基準值 Note 2 indicates that the percentage content of the restricted substance does not exceed the refe...

Page 46: ...46 CE0128TB CE0128PB CE0152TB CE0152PB Installation Guide ...

Reviews: