Lenovo BladeCenter Virtual Fabric 10Gb Switch Module Product Manual Download Page 3

Optical cables for 1 GbE SX SFP and 10 GbE SR SFP+ transceivers
Lenovo 0.5m LC-LC OM3 MMF Cable

00MN499

ASR5

10

Lenovo 1m LC-LC OM3 MMF Cable

00MN502

ASR6

10

Lenovo 3m LC-LC OM3 MMF Cable

00MN505

ASR7

10

Lenovo 5m LC-LC OM3 MMF Cable

00MN508

ASR8

10

Lenovo 10m LC-LC OM3 MMF Cable

00MN511

ASR9

10

Lenovo 15m LC-LC OM3 MMF Cable

00MN514

ASRA

10

Lenovo 25m LC-LC OM3 MMF Cable

00MN517

ASRB

10

Lenovo 30m LC-LC OM3 MMF Cable

00MN520

ASRC

10

Passive SFP+ direct-attach cables - 10 GbE
Lenovo 0.5m Passive SFP+ DAC Cable

00D6288

A3RG

10

Lenovo 1m Passive SFP+ DAC Cable

90Y9427

A1PH

10

Lenovo 1.5m Passive SFP+ DAC Cable

00AY764

A51N

10

Lenovo 2m Passive SFP+ DAC Cable

00AY765

A51P

10

Lenovo 3m Passive SFP+ DAC Cable

90Y9430

A1PJ

10

Lenovo 5m Passive SFP+ DAC Cable

90Y9433

A1PK

10

Lenovo 7m Passive SFP+ DAC Cable

00D6151

A3RH

10

Active SFP+ direct-attach cables - 10 GbE
1m 10GE Twinax Act Copper SFP+

81Y8295

A18M

10

3m 10GE Twinax Act Copper SFP+

81Y8296

A18N

10

5m 10GE Twinax Act Copper SFP+

81Y8297

A18P

10

Description

Part
number

Feature
code

Maximum
quantity
supported

Benefits

The Virtual Fabric 10Gb Switch Module offers the following benefits:

Integration and consolidation : This switch consolidates full Layer 2-3 LAN switching and routing

capabilities into a single BladeCenter chassis. This helps flatten the data center infrastructure and

reduces the number of discrete devices, management consoles, and equipment that administrators

must deal with, helping lower costs and simplifying deployment.
Cost: The switch is priced extremely competitively compared with external switches, especially

when you factor in that no cables are required between the blade and the switch. In addition, the

ability to use direct-attach cables with the switch can help clients save even more compared with

the more expensive CX4, XFP, or X2 transceivers.
Performance: With support for ten 10 Gb uplinks, clients can exploit not only up to 200 Gbps of bi-

directional uplink bandwidth, but also an extremely low oversubscription (14 to 10), which can

support even the most performance-intensive environments (up to 7.2 Gbps per blade server port).

Clients wanting extreme performance can use up to four switches and the quad port 10 Gb adapter

and get up to 1.92 Tbps of data per BladeCenter H chassis.
Lower power consumption: Using only 75 W per switch delivers extreme performance per watt,

which is second to none with its support for up to 6.4 Gbps per watt of power.
Layer 3 functionality: The switch module includes Layer 3 functionality, which provides security

and performance benefits as inter-VLAN traffic stays within the chassis. This switch also provides

the full range of Layer 3 protocols from static routes for technologies such as Open Shortest Path

First (OSPF) and Border Gateway Protocol (BGP) for enterprise customers.

BladeCenter Virtual Fabric 10Gb Switch Module (withdrawn product)

3

Summary of Contents for BladeCenter Virtual Fabric 10Gb Switch Module

Page 1: ...ds Figure 1 shows the switch module Figure 1 BladeCenter Virtual Fabric 10Gb Switch Module Did you know As virtualization has become a prevalent standard in the data center more people have been looking for ways to virtualize I O to reduce cost and complexity while also maximizing I O resources Virtual Fabric for BladeCenter provides fast flexible easy and reliable I O using the Virtual Fabric 10G...

Page 2: ...mode fiber or the 1000BASE LX transceivers that support distances up to 10 kilometers by using single mode fiber 1310 nm For 10 GbE on external SFP ports clients can use SFP direct attached copper DAC cables for in rack cabling and distances up to 7 meters These DAC cables have SFP connectors on each end and they do not need separate transceivers For longer distances the 10GBASE SR transceiver can...

Page 3: ...ture and reduces the number of discrete devices management consoles and equipment that administrators must deal with helping lower costs and simplifying deployment Cost The switch is priced extremely competitively compared with external switches especially when you factor in that no cables are required between the blade and the switch In addition the ability to use direct attach cables with the sw...

Page 4: ...hat will split out the LAN traffic Ethernet and the SAN Fiber Channel traffic For the latest FCoE gateway devices that are supported visit http lenovopress com bcig Virtual Fabric for BladeCenter This feature enables clients to implement and manage the Virtual Fabric solution via a graphical interface or CLI It is through this that administrators can perform tasks such as activating a Virtual Fabr...

Page 5: ...VRRP for Layer 3 router redundancy IEEE 802 1D STP for providing Layer 2 redundancy with PVRST IEEE 802 1s Multiple STP MSTP for topology optimization up to 128 STP instances supported by single switch IEEE 802 1w Rapid STP RSTP providing rapid STP convergence for critical delay sensitive traffic like voice or video Layer 2 Trunk Failover to support active standby configurations of network adapter...

Page 6: ...col data units Virtual Station Interface VSI Discovery and Configuration Protocol VDP allows centralized configuration of network policies that persist with the VM independent of its location EVB Type Length Value TLV is used to discover and configure VEPA ECP and VDP VMready Up to 2 048 virtual entities VEs Automatic VE discovery Up to 1 024 local or distributed VM groups for VEs NMotion feature ...

Page 7: ...for monitoring traffic in data networks separate sFLOW analyzer required elsewhere POST diagnostics Special functions Serial over LAN SOL The following features are not supported with IPv6 Default switch management IP address SNMP trap host destination IP address Bootstrap Protocol BOOTP and DHCP RADIUS TACACS and LDAP QoS metering and re marking ACLs for out profile traffic VMware Virtual Center ...

Page 8: ...Control IEEE 802 3z 1000BASE SX short range fiber optics Gigabit Ethernet IEEE 802 3z 1000BASE LX long range fiber optics Gigabit Ethernet SFF 8431 10GSFP Cu SFP Direct Attach Cable Chassis and expansion cards The Virtual Fabric 10Gb Switch is supported in the BladeCenter H and HT chassis as shown in Table 3 Table 3 BladeCenter chassis that supports the Virtual Fabric 10Gb Switch Module BladeCente...

Page 9: ...fits in one of the high speed I O bay bays 7 10 For each supported adapter the Table 5 lists which specific chassis I O bays are supported Table 5 Virtual Fabric 10Gb Switch Module and BladeCenter chassis I O bays support Description Part number 10Gb Interposer Card for HS23 94Y8550 N N N N N N Y N Y N 2 4 Port Ethernet Expansion Card CFFh 44W4479 N N N N N N Y Y Y Y Broadcom 10Gb Gen 2 2 port Eth...

Page 10: ...ule and the network OK indicates that the switch module has passed the power on self test POST with no critical faults and is operational Switch module error indicates that the switch module has failed the POST or detected an operational fault One USB RS 232 console port provides an additional means to install software and configure the switch module This USB style connector enables the connection...

Page 11: ...ansceiver 00FE333 1000BASE T UTP Category 5 5E and 6 up to 100 meters RJ 45 1000BASE SX SFP Transceiver 81Y1622 1000BASE SX Up to 30 m with fiber optic cables supplied by Lenovo see Table 2 850 nm multimode fiber cable up to 550 m 50 µ or up to 220 m 62 5 µ LC 1000BASE LX SFP Transceiver 90Y9424 1000BASE LX 1310 nm single mode fiber cable up to 10 km LC Management ports External 1 GbE management p...

Page 12: ... server In UFP mode the Virtual Fabric 10Gb Switch is vPort aware that is the configuration of vPorts is performed on a switch then it propagates vPorts parameters to VFA vPort bandwidth allocation and metering is performed by the switch and the VFA In such a case a bidirectional virtual channel of an assigned bandwidth is established between them for each vPort The Virtual Fabric 10Gb Switch is c...

Page 13: ...der FCF which is functioning as an aggregation switch and an FCoE gateway The example scenario with NAS iSCSI and FCoE storage targets is shown in Figure 4 Note For more information about supported FCoE and iSCSI configurations see the following System Storage Interoperation Center SSIC website http ibm com systems support storage ssic Figure 4 Converged network Related publications and links Blad...

Page 14: ...uct Guide Emulex 10GbE VFA II and Emulex 10GbE VFA Advanced II for BladeCenter HS23 http lenovopress com tips0875 Lenovo Press Product Guide Emulex Virtual Fabric Adapter CFFh for BladeCenter http lenovopress com tips0748 Lenovo Press Product Guide QLogic Virtual Fabric Extension Module for BladeCenter http lenovopress com tips0717 US Announcement Letter http ibm com common ssi cgi bin ssialias in...

Page 15: ...ed for use in implantation or other life support applications where malfunction may result in injury or death to persons The information contained in this document does not affect or change Lenovo product specifications or warranties Nothing in this document shall operate as an express or implied license or indemnity under the intellectual property rights of Lenovo or third parties All information...

Page 16: ...g terms are trademarks of Lenovo in the United States other countries or both BladeCenter Interoperability Guide BladeCenter Lenovo NMotion RackSwitch System x VMready vNIC The following terms are trademarks of other companies Hyper V is a trademark of Microsoft Corporation in the United States other countries or both Other company product or service names may be trademarks or service marks of oth...

Reviews: