I/O bays 7 - 10 are used for high-speed switch modules such as the Virtual Fabric 10 Gb Switch Module

or Cisco Nexus 4001I Switch Module. These bays are routed internally through midplane connectors to

the ports on CFFh expansion cards (with HS23 blade, I/O bays 7 and 9 are routed to the integrated

10GbE ports on HS23 through LOM Interposer Card). I/O bays 7 - 10 can also be converted to the

standard I/O bays with the Multi-Switch Interconnect Module (MSIM).

The I/O modules must be compatible with the I/O interfaces that are present in the blade servers. For example,

when a Fibre Channel expansion card is installed in a blade server, I/O modules 3 and 4 must also be Fibre

Channel-based (that is, an FC switch module), and vice versa. If you install FC switches in bays 3 and 4, then

any expansion cards that are installed in all other blade servers in the same chassis must be Fibre Channel.

Table 4 shows the connections between the adapter slots in the compute nodes to the switch bays in the

chassis.

Table 4. Adapter to I/O bay correspondence

I/O adapter
in each server

Port on the adapter

Corresponding I/O module bay
in the chassis

Onboard 1 Gb Ethernet

Port 1

I/O bay 1

Port 2

I/O bay 2

Onboard 10 Gb Ethernet (HS23)

Port 1

I/O bay 7

Port 2

I/O bay 9

CIOv adapter

Port 1

I/O bay 3

Port 2

I/O bay 4

CFFh adapter

Port 1

I/O bay 7

Port 2

I/O bay 9

Port 3

I/O bay 8

Port 4

I/O bay 10

Supported I/O modules

Tables 5 through 7 list the I/O modules that are supported by the BladeCenter H chassis and the corresponding

I/O bay into which the I/O module can be installed.

BladeCenter H

9

Summary of Contents for BladeCenter H

Page 1: ...rk switching power and cooling to support the individual servers Figure 1 shows the BladeCenter H chassis Figure 1 The BladeCenter H chassis Did you know BladeCenter H delivers high performance extreme reliability and ultimate flexibility to even the most demanding IT environments The chassis supports up to four traditional fabrics by using networking switches storage switches or pass through devi...

Page 2: ...nd SSL protocols for secure remote systems management IBM Systems Director remains a powerful and intelligent solution to manage BladeCenter systems along side rack mount and tower servers Systems Director uses the hardware s capabilities by surfacing pertinent information about your blade server The easy to use wizards provide step by step instructions and offer automated deployment capabilities ...

Page 3: ...helps reduce energy costs with leadership high efficiency power supplies that are 94 efficient and 80 PLUS Platinum Certified The BladeCenter H uses hexagonal ventilation holes a part of Calibrated Vectored Cooling technology Hexagonal holes can be grouped more densely than round holes providing more efficient airflow through the system IBM Systems Director Active Energy Manager provides advanced ...

Page 4: ...Figure 3 Rear of the BladeCenter H chassis Standard specifications BladeCenter H 4 ...

Page 5: ...net port for remote management Media tray Two USB 2 0 ports Rear One serial breakout port for optional serial breakout cable Cooling Calibrated Vectored Cooling with two standard or enhanced redundant hot swap blower modules model dependent You can have up to four fan packs with power modules one fan pack per each power module Power modules Up to four redundant hot swap 2900 W older models or 2980...

Page 6: ...r 8x Brocade 10Gb SFP SR Optical Transceiver 8x Cisco 10GBASE SR SFP Transceiver 8x 10GbE 850 nm Fiber SFP Transceiver SR 4x 8Gb SFP SW Optical Transceiver Software standard 1x BladeCenter Open Fabric Manager Basic 1x BladeCenter Open Fabric Manager Basic 1x BladeCenter Open Fabric Manager Basic Power supplies std max 2x 2980 W 4 4x 2980 W 4 4x 2980 W 4 4x 2980 W 4 Enhanced blowers std max 2 2 2 2...

Page 7: ...4 BladeCenter PS702 All 7 7 7 7 BladeCenter PS703 All 14 14 14 14 BladeCenter PS704 All 7 7 7 7 The support that is shown is for Intel Xeon standard thermal profile processors all except Intel Xeon E5 2618L v2 E5 2628L v2 E5 2648L v2 and E5 2658 v2 Intel Xeon E5 2697 v2 and E5 2690 v2 processors throttle at Steady State at ambient temperature of 31 C in the BladeCenter H chassis When one blower fa...

Page 8: ...d Ethernet compatible I O modules These bays are routed internally to the onboard Ethernet controllers on the blades Bays 3 and 4 can be used either for standard switch or pass through modules such as 8 Gb Fibre Channel or Gigabit Ethernet modules or for bridge modules These bays are routed internally to the CIOv connector on the blades Bays 5 and 6 are dedicated for bridge modules only and do not...

Page 9: ...t is an FC switch module and vice versa If you install FC switches in bays 3 and 4 then any expansion cards that are installed in all other blade servers in the same chassis must be Fibre Channel Table 4 shows the connections between the adapter slots in the compute nodes to the switch bays in the chassis Table 4 Adapter to I O bay correspondence I O adapter in each server Port on the adapter Corr...

Page 10: ... Y Y Y L2 3 Copper GbE Switch Module 32R1860 1495 3212 Y Y Y Y N N Y Y Y Y L2 3 Fiber GbE Switch Module 32R1861 1496 3213 Y Y Y Y N N Y Y Y Y L2 7 Gb Ethernet Switch Module 32R1859 1494 3211 Y Y Y Y N N N N N N Server Connectivity Module 39Y9324 1484 3220 Y Y Y Y N N Y Y Y Y 10 Gb Ethernet Brocade Converged 10GbE Switch Module 69Y1909 7656 none N N N N N N Y Y Cisco Nexus 4001I Switch Module 46M60...

Page 11: ...hru Module 88Y6410 A24D none N N Y Y N N N Y N Y QLogic Virtual Fabric Extension Module 46M6172 4799 none N N Y N Y N N N N N Withdrawn not available for ordering Requires MSIM 39Y9314 feature code 1465 or MSIM HT 44R5913 feature code 5491 to be installed in high speed I O bays 7 and 8 or 9 and 10 or both when the module is used in bay 8 or 10 or both Table 7 Supported SAS InfiniBand Pass thru and...

Page 12: ...mum supported Standard models where used 46M0901 4161 UltraSlim Enhanced SATA DVD ROM 1 46M0902 4163 UltraSlim Enhanced SATA Multi Burner 1 94x 95x 96x UltraSlim Enhanced SATA DVD ROM part number 46M0901 supports the following media and speeds for reading CD ROM 24X CD R 24X CD RW 24X DVD ROM 4 7 GB 8X DVD ROM dual layer 8 5 GB 8X DVD R 4 7 GB 8X DVD R dual layer 8 5 GB 8X DVD R 4 7 GB 8X DVD R du...

Page 13: ...e 9 shows the AMM ordering information Table 9 Advanced Management Module Part number Feature code Description 2019A1X 1604 Advanced Management Module for BladeCenter Figure 5 shows the Advanced Management Module Figure 5 Advanced Management Module The following tasks can be performed with AMM Defining the login IDs and passwords Configuring security settings such as data encryption and user accou...

Page 14: ...dvanced Management Module Installation Guide found at http ibm com support entry portal docdisplay lndocid MIGR 5073392 BladeCenter Advanced Management Module User s Guide found at http ibm com support entry portal docdisplay lndocid MIGR 5073887 Advanced Management Module Command Line Interface Reference Guide found at http ibm com support entry portal docdisplay lndocid MIGR 54667 Serial console...

Page 15: ...em separately two power cables per one chassis Table 12 contains the ordering information for power cables Table 12 Power cable ordering part numbers and feature codes Part number Feature code Description 25R5783 6270 4 3 m 208 V Double 30A NEMA L6 30P 25R5784 6271 4 3 m 230 V Dual 32A IEC 309 P N G 16A IEC 320 C20 25R5785 6226 2 8 m 200 240 V Triple 16A IEC 320 C20 25R5811 6273 4 3 m 220 V Double...

Page 16: ...tandard call center support and 9x5 Next Business Day onsite coverage Also available are Lenovo Services warranty maintenance upgrades and post warranty maintenance agreements with a well defined scope of services including service hours response time term of service and service agreement terms and conditions Lenovo warranty service upgrade offerings are country specific Not all warranty service u...

Page 17: ... The following Lenovo warranty service upgrades are available Warranty and maintenance service upgrades Three four or five years of 9x5 or 24x7 service coverage Onsite response from next business day to 2 or 4 hours Committed repair service Warranty extension of up to 5 years Post warranty extensions Committed Repair Service Committed Repair Services enhances the level of Warranty Service Upgrade ...

Page 18: ...ge systems Table 15 lists the external storage systems that are supported by the blade servers that are installed in the BladeCenter H chassis and can be ordered through the System x sales channel The servers might support other disk systems that are not listed in this table For more information see the IBM System Storage Interoperation Center at http www ibm com systems support storage ssic Table...

Page 19: ...rd 3628L4X Half High LTO Gen 4 External SAS Tape Drive with US power cord 3628L5X Half High LTO Gen 5 External SAS Tape Drive with US power cord 3628N3X Half High LTO Gen 3 External SAS Tape Drive without power cord 3628N4X Half High LTO Gen 4 External SAS Tape Drive without power cord 3628N5X Half High LTO Gen 5 External SAS Tape Drive without power cord 3580S3V System Storage TS2230 Tape Drive E...

Page 20: ...t 7159B1X Lenovo ThinkSystem NE1032T RackSwitch Rear to Front 7159C1X Lenovo ThinkSystem NE1072T RackSwitch Rear to Front 7159BR6 Lenovo RackSwitch G8124E Rear to Front 7159G64 Lenovo RackSwitch G8264 Rear to Front 7159DRX Lenovo RackSwitch G8264CS Rear to Front 7159CRW Lenovo RackSwitch G8272 Rear to Front 7159GR6 Lenovo RackSwitch G8296 Rear to Front 25 Gb Ethernet switches 7159E1X Lenovo ThinkS...

Page 21: ...SWL SFP Enterprise SW 1 PS Rail Kit 3873AR5 Lenovo B6505 12 ports activated w 16Gb SWL SFPs 1 PS Rail Kit 3873BR3 Lenovo B6510 24 ports activated w 16Gb SWL SFPs 2 PS Rail Kit 32 Gb FC 6559D3Y Lenovo ThinkSystem DB610S 8 ports activated 1 PS Rail Kit 6415G11 Lenovo ThinkSystem DB620S 24 Ports Activated 24x 32Gb SWL SFPs 2 PS Rail Kit 6415G2A Lenovo ThinkSystem DB620S 48 Ports Activated 48x 32Gb SW...

Page 22: ...ise PDUs 71762MX Ultra Density Enterprise PDU C19 PDU WW 71762NX Ultra Density Enterprise PDU C19 PDU WW 71763MU Ultra Density Enterprise PDU C19 3 phase 60A PDU NA 71763NU Ultra Density Enterprise PDU C19 3 phase 60A PDU NA 39Y8923 DPI 60A Three Phase C19 Enterprise PDU with IEC309 3P G 208 V fixed power cord 39Y8948 DPI Single Phase C19 Enterprise PDU without power cord Front end PDUs 39Y8934 DP...

Page 23: ...he following table Table 21 Rack cabinets Part number Description 201886X 11U Office Enablement Kit 93072PX 25U Static S2 Standard Rack 93072RX 25U Standard Rack 93074RX 42U Standard Rack 93074XX 42U Standard Rack Extension 93084EX 42U Enterprise Expansion Rack 93084PX 42U Enterprise Rack 93604EX 42U 1200mm Deep Dynamic Expansion Rack 93604PX 42U 1200mm Deep Dynamic Rack 93614EX 42U 1200mm Deep St...

Page 24: ... capital for other uses We work with businesses non profit organizations governments and educational institutions to finance their entire technology solution We focus on making it easy to do business with us Our highly experienced team of finance professionals operates in a work culture that emphasizes the importance of providing outstanding customer service Our systems processes and flexible poli...

Page 25: ...nation and Service Guide BladeCenter H http ibm com support entry portal docdisplay lndocid MIGR 63570 BladeCenter Products and Technology SG24 7523 http lenovopress com sg247523 BladeCenter Interoperability Guide http lenovopress com bcig BladeCenter Power Guide http ibm com support entry portal docdisplay lndocid LNVO POWINF Configuration and Option Guide http www ibm com systems xbc cog xREF Sy...

Page 26: ...s document are not intended for use in implantation or other life support applications where malfunction may result in injury or death to persons The information contained in this document does not affect or change Lenovo product specifications or warranties Nothing in this document shall operate as an express or implied license or indemnity under the intellectual property rights of Lenovo or thir...

Page 27: ...eCenter Open Fabric BladeCenter Lenovo Services Lenovo MAX5 RackSwitch ServerProven System x ThinkSystem The following terms are trademarks of other companies Intel and Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries Linux is a trademark of Linus Torvalds in the United States other countries or both Microsoft and Window...

Reviews: