• “A drive has failed with yellow LED lit” on page 234
• “A newly installed drive is not recognized.” on page 234
• “Drive(s) installed in the server are not detected by SAS controller” on page 234
• “Operating system cannot be installed to NVMe drives that are set with Intel VROC” on page 235
Server cannot recognize a drive
Complete the following procedure to solve the problem.
1. Observe the associated yellow drive status LED. If the LED is lit, it indicates a drive fault.
2. If the LED is lit, remove the drive from the bay, wait 45 seconds, and reinsert the drive, making sure that
the drive assembly connects to the drive backplane.
3. Observe the associated green drive activity LED and the yellow status LED:
• If the green activity LED is flashing and the yellow status LED is not lit, the drive is recognized by the
controller and is working correctly. Run the diagnostics tests for the hard disk drives. When you start
a server and press F1, the Lenovo XClarity Provisioning Manager V3 interface is displayed by default.
You can perform hard drive diagnostics from this interface. From the Diagnostic page, click
Run
Diagnostic
➙
Disk Drive Test
.
• If the green activity LED is flashing and the yellow status LED is flashing slowly, the drive is
recognized by the controller and is rebuilding.
• If neither LED is lit or flashing, check the drive backplane.
• If the green activity LED is flashing and the yellow status LED is lit, replace the drive. If the activity of
the LEDs remains the same, go to step drive problems. If the activity of the LEDs changes, return to
step 1.
4. Make sure that the drive backplane is correctly seated. When it is correctly seated, the drive assemblies
correctly connect to the backplane without bowing or causing movement of the backplane.
5. Reseat the backplane power cable and repeat steps 1 through 3.
6. Reseat the backplane signal cable and repeat steps 1 through 3.
7. Suspect the backplane signal cable or the backplane:
• Replace the affected backplane signal cable.
• Replace the affected backplane.
8. Run the diagnostics tests for the SATA/SAS adapter and drives. When you start a server and press F1,
the Lenovo XClarity Provisioning Manager V3 interface is displayed by default. You can perform drive
diagnostics from this interface. From the Diagnostic page, click
Run Diagnostic
➙
Disk Drive Test
.
Based on those tests:
• If the adapter passes the test but the drives are not recognized, replace the backplane signal cable
and run the tests again.
• Replace the backplane.
• If the adapter fails the test, disconnect the backplane signal cable from the adapter and run the tests
again.
• If the adapter fails the test, replace the adapter.
Multiple drives fail
Complete the following procedure to solve the problem.
• View the Lenovo XClarity Controller event log for events related to power supplies or vibration issues and
resolve those events.
232
ThinkSystem SR850 V2 Maintenance Manual
Summary of Contents for 7D31
Page 1: ...ThinkSystem SR850 V2 Maintenance Manual Machine Types 7D31 and 7D32 ...
Page 8: ...vi ThinkSystem SR850 V2 Maintenance Manual ...
Page 52: ...44 ThinkSystem SR850 V2 Maintenance Manual ...
Page 60: ... Three backplanes on page 57 52 ThinkSystem SR850 V2 Maintenance Manual ...
Page 70: ...62 ThinkSystem SR850 V2 Maintenance Manual ...
Page 71: ...Chapter 3 Internal cable routing 63 ...
Page 78: ...70 ThinkSystem SR850 V2 Maintenance Manual ...
Page 114: ...106 ThinkSystem SR850 V2 Maintenance Manual ...
Page 236: ...Figure 133 System board and expansion board LEDs 228 ThinkSystem SR850 V2 Maintenance Manual ...
Page 258: ...250 ThinkSystem SR850 V2 Maintenance Manual ...
Page 260: ...252 ThinkSystem SR850 V2 Maintenance Manual ...
Page 264: ...256 ThinkSystem SR850 V2 Maintenance Manual ...
Page 273: ......
Page 274: ......