NAME
LABEL
SIZE
MEDIATYPE
STATE
LOCATION
ENCLOSURELABELUSEDNAME
c1t50000393
B8C83E9Cd0
-
0,0K
hdd
RETIRED
50030480015
a6b7f:15
-
Note:
c1t50000393B8C83E9Cd0
represents the name of the failed drive in command lines in the following
steps.
3. To physically locate the failed drive, activate the blinking feature of the LED of the failed drive:
CLI@nexenta> disk indicators —ident=ON c1t50000393B8C83E9Cd0
Verify if the LED is on. The LED is blinking if the ident value is Yes.
CLI@nexenta> disk indicators c1t50000393B8C83E9Cd0
NAME
PROPERTY
VALUE
ident
enabled
yes
fail
enabled
no
ok2rm
enabled
no
4. Set the failed drive to be
offline
in the storage pool to prevent writing to or reading from the drive. This
command line is not applicable for spare or cache drives.
CLI@nexenta> pool offline <pool> <disk>
Example:
CLI@nexenta> pool offline poola c1t50000393B8C83E9Cd0
5. Physically replace the failed drive.
• To replace the failed drive in the Lenovo Storage DX8200N storage system, refer to the
Lenovo
System x3650 M5 Installation and Service Guide
at:
http://datacentersupport.lenovo.com
• To replace the failed drive in Lenovo JBOD D1212/D1224/D3284, refer to the
Hardware Installation
and Maintenance Guide - Lenovo Storage D1212/D1224/D3284
at:
http://datacentersupport.lenovo.com
6. Identify the new drive:
CLI@nexenta> disk list
The name of the new drive is displayed, for example:
c1t5000CCA39ACF89DAd0
.
7. Replace the failed drive with a new drive in the same storage pool.
CLI@nexenta> pool replace [-fnv] poola c1t50000393B8C83E9Cd0 <new-disk>
Example:
CLI@nexenta> pool replace [-fnv] poola c1t50000393B8C83E9Cd0 c1t5000CCA39ACF89DAd0
To optimize the performance, it is recommended that the new drive is the same size, speed, and media
type as the failed one.
8. Set the new drive in the storage pool to be
online
.
CLI@nexenta> pool online [-env] poola c1t5000CCA39ACF89DAd0
Features on Demand
The Lenovo Storage DX8200N storage system is provided with an IMM Advanced Upgrade Features on
Demand (FoD) key that helps activate and install FoD upgrades.
10
Lenovo Storage DX8200N Serviceability Guide
Summary of Contents for 5128
Page 1: ...Lenovo Storage DX8200N Serviceability Guide Machine Type 5128 ...
Page 4: ...ii Lenovo Storage DX8200N Serviceability Guide ...
Page 12: ...8 Lenovo Storage DX8200N Serviceability Guide ...
Page 16: ...12 Lenovo Storage DX8200N Serviceability Guide ...
Page 18: ...14 Lenovo Storage DX8200N Serviceability Guide ...
Page 20: ...16 Lenovo Storage DX8200N Serviceability Guide ...
Page 21: ......
Page 22: ......