5

The LogiPanel GEL 8819 can be programmed in the LB-
Flex plain-text programming language which is based on
IEC standard 1131-3, „Structured text“.

The plain-text programming language makes use of
natural language elements which - when used in conjunc-
tion with some basic rules - will lead in a short time to
executable programs.

Applications can therefore be programmed in a clear and
almost self-explaining way by means of the simple and
more complex instructions required for LogiPanel pro-
gramming.

The LB-Flex language makes use, among other things, of
elements and notations used in algebra and in higher
programming languages and offers the possibility of not
only checking an input status, but also of performing the
complex calculation of nominal positions.

Programming language elements

mnemonic and symbolic variables representing the
following types of data: bit, byte, word, dword and
pointer

•••••

constants and symbolic constants

•••••

arithmetical and logical operators, bit and
address operators

•••••

sequence control instructions and
program structuring instructions

•••••

mathematical functions

•••••

conversion functions

•••••

operating and monitoring functions

•••••

specific device functions

•••••

travelling and positioning functions

access functions for converter variables

INCLUDE instructions operating on definition
and library files

The use of symbolic variables and constants with user-
defined denominations ensures perfect transparency of
your programs.

Free programming

File manager for standard programming

Parameter editor with online help

Program editor

Summary of Contents for MotionLine LogiPanel GEL 8819

Page 1: ...f 160 mm x 160 mm and a depth of 57 mm The sealed membrane keypad is extremely user friendly with its 18 mm x 18 mm keys and slide in marking labels which can be easily adapted to customer specific needs A large backlit LCD display ensures easy reading even under adverse lighting conditions The display contrast can be adjusted to individual requirements Serial interfaces The user has the choice be...

Page 2: ...o i t a c i l p p a c i t a m i l C e r u t a r e p m e t g n i t a r e p O C 0 5 0 e r u t a r e p m e t e g a r o t S C 0 8 C 0 2 y t i d i m u h r i a e v i t a l e R n o i t a s n e d n o c e r u t s i o m o n 5 9 o t p u d e v r e s b o s n o i t c u r t s n i g n i t n u o m y t i l i b i t a p m o c c i t e n g a m o r t c e l E s n o i s s i m e c i t e n g a m o r t c e l E 1 1 8 0 0 5 N ...

Page 3: ... e r M 3 A c h s e n P N r 7 T i p p g e s c h w I s 1 0 0 0 0 7 8 9 0 F1 N x ESC F2 N x P 1 DIR 1 5 6 2 3 4 delete entry scroll menu number confirm ENTER escape entry menu start travel sequence stop drive direct entry of nominal position and speed enter number travel sequence no parameter no menu to next higher level inching mode manual control F1 decrement travel sequence no parameter no 10 F2 i...

Page 4: ...r 1 m ALC 121 1 Software PG 8819 and LP 2000 on CD ROM LP 2000 on disk Dimensions 160 150 46 5 4 21 5 25 A B C SW1 SW2 Control panel cut out 151 mm Type code Subject to technical modifications and typographical errors For the latest version please visit our web site www lenord de 9 1 8 8 0 _ _ 0 e r a w t f o S 0 0 0 2 P L F G s e c a f r e t n I s u b N A C d n a C 2 3 2 S R d e t a r a p e s y l...

Page 5: ...ity of not only checking an input status but also of performing the complex calculation of nominal positions Programming language elements mnemonic and symbolic variables representing the following types of data bit byte word dword and pointer constants and symbolic constants arithmetical and logical operators bit and address operators sequence control instructions and program structuring instruct...

Page 6: ... 0 9 A 2 x 30 V U 10 k 3 k 1 2 3 4 5 6 7 8 9 female RxTx RxTx SW2 1 1 SW2 2 5 V 470 180 470 1 switch SW2 in position ON standard for terminating resistor in terminal unit Terminal strip A E288125N Connector B RS 485 interface E288147B Connector B RS 232 C interface E288147C Connector C CAN bus interface E280147C 1 2 3 4 5 6 7 8 9 female 0 V CAN CAN SW1 1 in position ON standard for terminating res...

Reviews: