Page 6
208/230V-60 Hz-1 Ph
Model Number
Label Rev.
Unit
Compressor
Condenser Fan
Maximum
Over-
current
Protection
(amps)
1
Minimum
Circuity
Ampacity
2
Rated
Load
Amps
(RLA)
Locked
Rotor
Amps
(LRA)
Motor HP
Nominal
RPM
Full Load
Amps
(FLA)
Locked
Rotor
Amps
(LRA)
XP14-048-230-01
1.0, 2.0 &
3.0
50
29.0
21.79
117.0
1/3
825
1.8
2.1
XP14-048-230-02
1.0
50
29.0
21.79
117.0
1/3
825
1.8
2.1
XP14-048-230-08
1.0
50
29.0
21.76
117.0
1/3
825
1.8
2.1
XP14-048-230-09
1.0
50
29.0
21.79
117.0
1/3
825
1.8
2.1
2.0 & 3.0
50
29.0
21.76
117.0
1/3
825
1.8
2.1
208/230V-60 Hz-1 Ph
Model Number
Label Rev.
Unit
Compressor
Condenser Fan
Maximum
Over-
current
Protection
(amps)
1
Minimum
Circuity
Ampacity
2
Rated
Load
Amps
(RLA)
Locked
Rotor
Amps
(LRA)
Motor HP
Nominal
RPM
Full Load
Amps
(FLA)
Locked
Rotor
Amps
(LRA)
XP14-060-230-01
1.0 & 2.0
60
34.8
26.41
134.0
1/3
825
1.8
2.1
XP14-060-230-03
1.0
60
34.8
26.41
134.0
1/3
825
1.8
2.1
XP14-060-230-08
1.0
60
34.8
26.41
134.0
1/3
825
1.8
2.1
2.0, 3.0 &
4.0
50
29.4
22.10
125.0
1/3
825
1.8
2.1
XP14-060-230-09
1.0
60
29.4
26.41
125.0
1/3
825
1.8
2.1
1
HACR type circuit breaker or fuse.
2
Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements.