1 Safety Precautions   

 

WARNING

 

(1)  This product can’t be installed at corrosive, inflammable or explosive environment or the place with 

special requirements, such as kitchen. Otherwise, it will affect the normal operation or shorten the service 
life of the unit, or even cause fire hazard or serious injury. As for above special places, please adopt 
special air conditioner with anti-corrosive or anti-explosion function. 

(2)  Follow this instruction to complete the installation work. Please carefully read this manual before unit   
(3)  startup and service. 

(4)  Wire size of power cord should be large enough.The damaged power cord and connection wire should 

be replaced by exclusive cable. 

(5)  After connecting the power cord, please fix the electric box cover properly in order to avoid accident. 

(6)  Never fail to comply with the nitrigen charge requirements.Charge nitrogen when welding pipes. 

(7)  Never short-circiut or cancel the pressure switch to prevent unit damage.   

(8)  Please firstly connect the wired controller before energization, otherwise wired controller can not be 

used. 

(9)  Before using the unit, please check if the piping and wiring are correct to avoid water leakage, refrigerant 

leakage, electric shock, or fire etc.. 

(10)  Do not insert fingers or objects into air outlet/inlet grille. 

(11)  Open the door and window and keep good ventilation in the room to avoid oxygen deficit when the gas/oil 

supplied heating equipment is used. 

(12)  Never start up or shut off the air conditioner by means of directly plug or unplug the power cord. 

(13)  Turn off the unit after it runs at least five minutes; otherwise it will influence oil return of the compressor. 

(14)  Do not allow children operate this unit. 

(15)  Do not operate this unit with wet hands. 

(16)  Turn off the unit or cut off the power supply before cleaning the unit, otherwise electric shock or injury 

may happen. 

(17)  Never spray or flush water towards unit, otherwise malfunction or electric shock may happen. 

(18)  Do not expose the unit to the moist or corrosive circumstances. 

(19)  Under cooling mode, please don't set the room temperature too low and keep the temperature difference 

between indoor and outdoor unit within 5°C (41°F). 

(20)  User is not allowed to repair the unit. Fault service may cause electric shock or fire accidents. Please 

contact 

LENNOX

 appointed service center for help.   

(21)  Before installation, please check if the power supply is in accordance with the requirements specified on 

the nameplate. And also take care of the power safety. 

Summary of Contents for VRF VEAH024C432P

Page 1: ...432P VEAH042C432P VEAH048C432P VEAH054C432P VRF Indoor Units Installation Manual Air Handler Fan Coil Thank you for selecting LENNOX air conditioners Please read this manual carefully before operation...

Page 2: ...y yourself If you need to disassemble and check units please contact our service center We will send specialists to guide the disassembly 6 All graphics in this manual is only for your reference For s...

Page 3: ...turer 3 After verification the defect of product is directly caused by corrosive gas 4 After verification defects are due to improper operation during transportation of product 5 Operate repair mainta...

Page 4: ...Removal 11 4 5 Ductwork 11 4 6 Installation of Wired Controller 12 5 Wiring Work 12 5 1 Connection of Wire and Patch Board Terminal 12 5 2 Power Cord Connection 13 5 3 Connection of Communication Wir...

Page 5: ...re correct to avoid water leakage refrigerant leakage electric shock or fire etc 10 Do not insert fingers or objects into air outlet inlet grille 11 Open the door and window and keep good ventilation...

Page 6: ...ion Do not cut off the power when 24 hours short time halting to protect the compressor 26 If refrigerant leakage happens during installation please ventilate immediately Poisonous gas will emerge if...

Page 7: ...ed Working Condition Indoor Side Condition Outdoor Side Condition Dry Bulb Temp C F Wet Bulb Temp C F Dry Bulb Temp C F Wet Bulb Temp C F Rated Cooling 27 80 6 19 66 2 35 95 24 75 2 Rated Heating 20 6...

Page 8: ...ities to install the product in accordance with such codes and or any prevailing local codes regulations The manufacturer assumes no responsibilities for equipment installed in violation of any codes...

Page 9: ...factory shipped for use with a 208 230 1 60 electrical power supply This air handler must not be reconfigured to operate with any other power supply WARNING The unit must have an uninterrupted unbroke...

Page 10: ...If the unit is installed in the place with strong electromagnetic interference shielded wire must be applied on the communication wire between indoor unit and wired controller Twisted pair line with...

Page 11: ...c field or strong interference it is necessary to use shielded wire communication line for outdoor unit Light Ordinary polyvinyl chloride sheathed cord UL60335 2011 L 1000 3280 2 18 UL60335 2011 3 4 W...

Page 12: ...The minimum distance between each stage of cut off device should be 3 mm 1 8 inch The same for both indoor unit and outdoor unit 4 Installation Instructions 4 1 Dimension Data Fig 4 1 Unit Inch mm MOD...

Page 13: ...he condenser that violates the instructions provided with the condenser Service clearance is to take precedence Allow a minimum of 24 in front of the unit for service clearance When installing in an a...

Page 14: ...h Gas Pipe in Liquid Pipe in VEAH024C432P 5 8 3 8 VEAH030C432P 5 8 3 8 VEAH036C432P 5 8 3 8 VEAH042C432P 5 8 3 8 VEAH048C432P 5 8 3 8 VEAH054C432P 5 8 3 8 4 3 2 Piping Preparation All cut ends are to...

Page 15: ...in connection s in order to prevent possible damage to the evaporator drain pan See Fig 4 4 for details of a typical condensate line P trap Fig 4 4 4 5 Ductwork This air handler is designed for a comp...

Page 16: ...away from refrigerant pipings compressor and fan motor 7 The communication wires should be separated from power cord and connection wire between indoor unit and outdoor unit 8 Adjust the static press...

Page 17: ...d 2 Let the power cord pass through the wiring through holes 3 Connect the power cord to terminal L N 4 Fix the power cord with wiring clamp 5 3 Connection of Communication Wire between Indoor Unit an...

Page 18: ...ng light board can be installed at the same time When operating through a remote controller both wired controller and the receiving light board can receive the signals 5 5 Illuminate for Connection of...

Page 19: ...VRF DC Air Handler 15 Fig 5 5...

Page 20: ...to remove dust If the filters are dirty wash them with warm water and mild detergent and dry the filters in the shade 2 If the unit used in the environment with much dust please clean it regularly Usu...

Page 21: ...an authorized service center for professional service The following checks prior to contact may save your time and money Phenomenon Troubleshooting The unit can t start Power supply is not connected C...

Page 22: ...t us at 1 305 718 2901 lennoxglobalhvac lennoxintl com C 2018 Lennox Industries Inc For a complete list of the registered and common law trademarks owned by Lennox Industries Inc please visit www lenn...

Reviews: